Warning
Do not operate your wireless network device near unshielded blasting caps or in an
explosive environment unless the device has been modified to be especially qualified for
such use. Statement 245B
The fasteners you use to mount an access point on a ceiling must be capable of
Caution
maintaining a minimum pullout force of 20 lbs (9 kg) and must use a minimum of 4 holes
on the mounting bracket, or a minimum of 2 holes when mounting on a network box.
This product and all interconnected equipment must be installed indoors within the same
Caution
building, including the associated LAN connections as defined by Environment A of the
IEEE 802.3af/at Standard.
The access point is suitable for use in environmental air space in accordance with section
Note
300.22.C of the National Electrical Code and sections 2-128, 12-010(3), and 12-100 of the
Canadian Electrical Code, Part 1, C22.1. You should not install the power supply or power
injector in air handling spaces.
Use only with listed Information Technology Equipment (ITE) equipment. For more
Note
information on ITE equipment, refer to article 645 of the latest National Electrical Code
(NEC).