Description of the device
3.3 RESET button
3.2
Device view
The following figure shows an overview of the components of the SCALANCE XF-200G.
①
②
③
④
⑤
⑥
⑦
⑧
⑨
3.3
RESET button
EXPLOSION HAZARD
Do not press the RESET button if there is a potentially explosive atmosphere.
22
Mounting screw
•
M4
•
Torx T20
•
Captive
LED display
•
F: Fault LED
•
RM: redundancy manager
•
L: Power LED, power supply
•
P: Port LEDs
Slot for C-PLUG
RESET button
Serial interface
Connector for power supply
Guide for mounting plates
Ground springs (grounding)
Electrical ports
WARNING
Operating Instructions, 02/2023, C79000-G8976-C676-01