Page 1
SIMATIC IPC377G Preface Overview SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC377G Commissioning the device and device functions Operating the device Operating Instructions Expanding and assigning parameters to the device Maintaining and repairing the device Technical specifications...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
USB stick in PDF format (in multiple languages). Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC377G in this documentation. Instead of the specific names of the operating system, we are using the abbreviation "Windows 10"...
Page 4
Preface History The following editions of these operating instructions have been published: Edition Comment 12/2021 First edition 07/2022 Add the UKCA certification SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Connect device to networks ....................34 Commissioning the device and device functions ................37 General information on commissioning ................37 Switching the device on/off ....................38 Operating the device ........................... 39 Overview ........................... 39 SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 6
USB 3.1 port ........................78 8.5.2.3 DC in connector ......................... 79 8.5.2.4 Ethernet port ........................79 8.5.2.5 DisplayPort ........................80 8.5.2.6 Serial interface ........................80 8.5.3 Internal interfaces ......................81 8.5.3.1 Overview of internal interfaces ..................81 SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 7
Markings and symbols ......................... 95 Overview ........................... 95 Safety ..........................95 Operator controls....................... 95 Certificates, approvals and markings .................. 96 Interfaces .......................... 97 List of abbreviations ..........................99 Abbreviations ........................99 Glossary ............................. 103 Index ..............................111 SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
• Compact design • High degree of ruggedness • Maintenance-free operation possibility SIMATIC IPC377G is available with various operating units that differ with regard to the display size. This display is a color display with a backlit "wide-screen" format TFT color display.
Keyboard, mouse Connection through USB port Audio (optional) Connection for analog audio source and speaker Operating systems Operation Systems • Without OS • Windows 10 Enterprise 2019 LTSC (Long Term Servicing Channel) 64-bit (MUI) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Bottom view and top view 15" Bottom view of 15" device is on the left, and top view is on the right. ① Interfaces and operating elements ② Recesses for mounting clips ③ Product label SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Example programs for controlling the LEDs on Windows operating systems are available on the Siemens Industry Automation and Drive Technology (https://support.industry.siemens.com/cs/us/en/) Accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Additional accessories can be found on the Internet: • Industry Mall (https://mall.industry.siemens.com) •...
Page 14
The Dust protection set interfaces contains: • 40 pieces covers for USB interface • 20 pieces covers for RJ45 Ethernet connection • 10 pieces DisplayPort cover Other accessories • Touch stylus only for devices with resistive single-touch screen SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
The installation of expansions can damage the device, machine or plant. Device and system expansions can violate safety rules and regulations regarding radio interference suppression. If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 16
• Replace the lithium battery only with an identical battery or types recommended by SIEMENS (article number: A5E48370874). • For any requirements on product maintenance, contact Siemens Technical support (Page 91). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
A damaged packaging indicates that ambient conditions have already had an impact on the device. The device might be damaged. Do not dispose of the original packaging. Pack the device during transportation and storage. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
The device can be clearly identified with the help of this identification data in case of repairs or theft. Enter the identification data in the following table: Identification data Source Value Serial number Product label S VP ... Order number Product label 6AV7231-0..Production version Product label SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 21
Product label Ethernet address 2 (MAC) Product label The following image shows the product label on the SIMATIC IPC377G as an example. COA label Microsoft Windows "Product Key" on the "Certificate Of Authenticity" (COA): The COA label is only attached to the rear of the device containing a preinstalled and activated Windows operating system.
For inclined installation in horizontal format, the following ambient temperatures are permitted: Maximum ambient temperature at the device Comment 12" and15" 19" and 22" 50 °C 45 °C The device enclosure fulfills the requirement of a fire protection enclosure. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
• Permissible deviation from plane at the mounting cutout: ≤ 0.5 mm This condition must be fulfilled for the mounted device. • Permissible surface roughness in the area of the seal: ≤ 120 µm (R 120) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
It may result in death or serious physical injury. Isolate the power supply to the control cabinet before opening it. Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 25
• Equip the control cabinet with struts for stabilizing the mounting cut-out. Install struts where necessary. • If you need to clean the device, use dry ESD cleaning cloths (observing the ESD protective measures). SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
To achieve the degree of protection for the device, the positions for the mounting clips shown below must be adhered to. The positions of the mounting clips are marked by stamps on the cutouts. Fit the mounting clips in all the stamped cutouts. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 27
The following table shows the type, number, and position of the mounting clips needed for the respective devices. IPC377G Mounting clips device Type Quantity Position on the device 12" display 15" display 19" display 22" display SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 28
0.5 Nm. Repeat step 2 and 3 to secure all mounting clips. Check the fitness of the mounting seal. Result The device is mounted and the relevant degree of protection is ensured at the front. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
3.2 Mounting the device 3.2.3 Fastening a device using a VESA adapter You can also fasten the SIMATIC IPC377G using a VESA (Video Electronics Standards Association) adapter. Different models of VESA adapters are offered by third-party manufacturers. The following sizes of the SIMATIC IPC377G support VESA installation: •...
• Always pull out the power plug when you are not using the device or if the device is defective. The power plug must be freely accessible. • Use a central power isolating switch for cabinet installation. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 31
Utilisez des câbles en cuivre (Cu) pour tous les câbles d'alimentation qui sont raccordés à l'appareil par des bornes, par exemple les câbles d'alimentation 24 V CC sur le connecteur d'alimentation 24 V CC. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
The external bonding facility should provide effective connection of a conductor with a cross sectional area of at least 4 mm Requirements • T20 screwdriver • Tightening torque: 1 Nm • Cable lug for M4 • Protective conductor with minimum cross-section of 2.5 mm (AWG14) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
• A two-core cable meets the following requirements: – a copper (Cu) cable cross-section of 0.75 mm to 2.5 mm – rated temperature 75 °C • Tightening torque: 0.56 Nm • A slotted screwdriver with approximate 3 mm blade. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
You can use the integrated Ethernet interfaces (10/100/1000 Mbps) for communication and data exchange with automation devices, for example SIMATIC S7. You need a suitable software to use this functionality: STEP 7, WinCC, SIMATIC NET. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 35
Control level. Information on this can be found on the SIMATIC NET Manual Collection CD. The software package and the documentation are not included in the product package. Additional information You can find additional information in Technical support. (Page 91) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 36
Installing and connecting the device 3.3 Connecting the device SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
• The device is connected to the power supply. • The function earth is connected. • The connection cables are plugged in correctly. • The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Procedure - Switching off the device To turn off the device, always select the function "Start" > "Shut down". Additional information Information on your operating system can be found on the Internet: • Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/en/view/109749498) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
The device variants differ with regard to their dimensions, display size, and touch sensors. The example in the following figure shows the front view of the 15" touchscreen variant. ① Display with touch screen SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
• Never use the touch screen to control safety-related functions. • Use a suitable touch pen to operate the touch screen. • Calibrate the touch screen regularly. • Cut off the power supply of the device for cleaning and maintenance. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 41
• Using a silicone finger with a diameter of 1.6 cm: 50 g. Note Only touch one point on the touch screen and not several points at one time, as this may trigger unintended reactions. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Lift up the box PC from the touch panel. Unplug the marked three cables on the motherboard. Procedure - closing the device To close the device, carry out the steps for opening the device in the reverse order. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Installing and removing M.2 Module Introduction to the M.2 Module Siemens uses the M.2 Module to extend the Siemens IPC. It can be produced by Siemens or other third-party suppliers. Our device provides one or several M.2 Key B interfaces and mounting positions.
Page 45
You can install 4G/5G SIM card through SIM card slot to connect to network. But SIM card function has not been certified in both ordinary location and hazardous location. Requirements • The device is opened. • A T8 screwdriver SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 46
Note: Make sure the M.2 Module board is located between head and spacer of assembly screw. If the M.2 Module has a cable with an additional interface-card connected to the housing opening, you need to do the following procedures: SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Installing and removing M.2 NVMe/SATA SSD Requirements • The device is disconnected from the power supply. • The device is opened. • A M.2 NVMe/SATA SSD that is approved for industrial applications. • A T10 screwdriver SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 48
Secure the M.2 NVMe/SATA SSD with the screw which is unscrewed in the first step. Procedure - removing the M.2 NVMe/SATA SSD Follow above steps in reverse order to remove the M.2 MVMe/SATA SSD. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Maintaining and repairing the device Maintenance intervals To maintain high system availability, Siemens recommends you replace some of the PC components that subject to wear in according with the replacement intervals indicated in the table below. Component Replacement interval: CMOS backup battery...
You may possibly trigger unwanted actions of the device or controller that are liable to cause personal injury or damage to the machinery. Always switch off the device before you clean it. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 51
2. Moisten only the cleaning cloth, do not spray liquids directly onto the device. 3. Clean the enclosure surface with a damp cloth and make sure that no water enters the device. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
– Rated voltage: 3 V DC – Max abnormal charging current: 10 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 91). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
Page 53
– Courant de charge anormal max. : 10 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 91) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
NOTICE Electrostatic discharge The electronic components on the PCBs are highly sensitive to electrostatic discharge. Always take appropriate precautionary measures when handling these components. Refer to the ESD directives on handling electrostatic sensitive components. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 55
7.4 Installing and removing hardware Note Siemens strongly recommends that you use only memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules. CAUTION • A memory module cab be installed only when the direction is correct. Make sure your insert the memory card in the correct direction.
Page 56
Do not touch or remove the CPU TIM on the inside of the housing when installing the motherboard back into it. Otherwise, it may result in CPU malfunction. ① M.2 NVMe/SATA SSD TIM ② CPU TIM SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
2. Start the program "START_DocuAndDrivers". 3. Select "Drivers" in the index. 4. Select the device and operating system. 5. Select the required driver. 6. Follow the below steps and click the icon to install the required driver. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 58
1. Click Step3: Intel® HECI Controller Driver. 2. Click to install the HECI Controller driver. 3. Click Yes to confirm the user account control question. 4. Click Next to continue. 5. Click Finish. The installation is completed. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 59
1. Click Step7: Intel® Graphics Command Center. 2. Click to install the Intel® Graphics Command Center. 3. Click Yes to confirm the user account control question. 4. Click Yes to continue. 5. Click Finish. The installation is completed. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Recycling and disposal Due to their low level of pollutants, the devices described in these operating instructions can be recycled. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
ISO 9001 certificate The Siemens quality management system for all production processes (Design and Manufacturing of Programmable Logic Controller (PLC), Human Machine Interface (HMI) and Industrial PC (IPC) used for Industry) meets the requirements of ISO 9001:2015.
Page 62
Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Responsible party for Supplier's Declaration of Conformity Siemens Industry, Inc. Digital Factory - Factory Automation 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 Mail to: (amps.automation@siemens.com)
Page 64
DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 60) ".
The following abbreviations are commonly used for electrostatic sensitive devices: • ESD – Electrostatic sensitive device • ESD – Electrostatic Sensitive Device as a common international designation Electrostatic sensitive devices can be labeled with an appropriate symbol. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 66
The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. ① Synthetic materials ② Wool ③ Antistatic materials such as wood or concrete SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 67
This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically by touching grounded metallic parts before you take a measurement at a module. Always use grounded measuring instruments. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4; Burst conducted interference • ± 1kV line to line, ±2 kV line to earth in accordance with IEC 61000-4-5; on the supply lines Surge SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 73
Slot X100: support NGFF M.2 2230/2242/2260/2280/3030/3042/3052 with Key B/Key B+M • Slot X101: support NGFF M.2 2230/2242/2260/3030/3042 with Key B/Key B+M Max. permitted total power loss for Less than 2.5 W each M.2 B key module SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 74
1 × USB pin header (2 USB 2.0 ports) • 1 × USB 2.0 type A connector (USB dongle) You can find additional information in the section "Power demand of the components (Page 76)". SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Storage: 20 °C/h, no condensation Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30 Operation Up to 85%, no condensation Gradient ≤ 10℃/h Storage/transport Up to 95% at 25/55 °C, no condensation Gradient ≤ 20℃/h Atmospheric pressure SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
900 mA 6 W (for all USB devices) USB device 2.0 High current 500 mA M.2 Module (slot Per slot 1.5 A 5 W in total X100) M.2 Module (slot Per slot 1.5 A X101) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
18.0 V during booting of the device is not permitted. Hardware descriptions 8.5.1 Technical features of the motherboard Component / Description Parameters port Chipset Integrated in CPU • Intel Atom® x6000E series Intel Processor • Intel Atom® x6413E Processor (up to 3.0 GHz) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Power out Data channel USB2 Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Orange light: Port is active but without data activity – Orange blink: Port is active and there is data activity Off: Port is not active The Ethernet interface supports MDXI (auto crossover) for all transmission rates. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Hot Plug Detect Input Ground DP_PWR +3.3 V (Power switch) power out 8.5.2.6 Serial interface RS232 RS422 RS485 Pin assignment RS232 Short description Meaning Data carrier detect (I) Received data (I) Transmitted data (O) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
8.5.3 Internal interfaces 8.5.3.1 Overview of internal interfaces Interface Position Description USB 2.0 Internal • 1 × USB pin header to 2 USB 2.0 ports Internal • PCIe × 2 lane + USB 2.0 SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
The following addresses are used for the internal registers: Addresses Input/output unit SIO logic device 8 CR F0h Watchdog control register (Page 86) SIO logic device 8 CR F1h Watchdog counter register (Page 86) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
SIO logic device 8 CR F2h Watchdog state register (Page 86) SIO logic device 7 CR FDh Battery status register (Page 87) For more information and reference code for accessing to Super IO, contact Siemens Technical support. 8.5.5.2 Watchdog control register...
The BIOS Setup program, or BIOS Setup for short, is located, together with the setup parameters, in a FLASH block on the motherboard. Change the setup parameters of the device in the BIOS Setup, e.g. system time or boot sequence. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/109797240). 8.6.2 BIOS update Check regularly if updates are available for download to your device. You can find additional information on the Internet at the following address: After-sales information system for SIMATIC PC/PG (http://www.siemens.com/asis). SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 89
If you have purchased a new BIOS update for your device, follow these steps to install the update: 1. Connect the device to the power supply. 2. Take the BIOS update you downloaded from the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/75852684) page and place it on the USB stick.
Check the CMOS clock. Keyboard error • Field PG: Internal keyboard defective and no external keyboard connected • Other devices: Keyboard defective or not connected SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
USB device does not respond The USB ports are not correctly • Turn on USB Legacy Support for mouse and supported. keyboard. • For other devices, you need the USB device drivers for the required operating system. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
If the error no longer occurs, the third-party module • Different pin assignment being used was the cause of the fault. Replace the third-party module with a Siemens module or contact the module supplier. If the device still crashes, contact your technical support team. •...
Page 94
Technical support A.3 Notes on the use of third-party modules SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical Eject CD/DVD isolation On/off switch, without electrical isolation SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters Disposal information, observe the Laboratories local regulations. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
DVI-D interface Line In LAN interface, not approved for Line Out connecting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Direct Memory Access Disk Operating System DisplayPort Deutsche Gesellschaft zur Zertifizierung von Qualitätsmanagement mBH Data Set Ready Ready for operation Data Terminal Ready Data terminal is ready Digital Versatile Disk Components sensitive to electrostatic charge SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 100
Association NTFS New Technology File System NVRAM Non Volatile Random Access Non-volatile data memory. Data memory is Memory retained without external power supply. Optical Disk Drive Personal computer Peripheral Component High-speed expansion bus Interconnect SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 101
Intel technology which provides a virtual, closed environment. VT-d Virtualization Technology for Enables the direct assignment of a device (e.g. Directed I/O network adapter) to a virtual device. Watchdog Program monitoring with error detection and alarming. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 102
List of abbreviations C.1 Abbreviations SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Communauté Européene: The CE symbol confirms the conformity of the product with all applicable EC directives such as the EMC Directive. Chipset Located on the motherboard, connects the processor with the PCI or PCIe bus and the external interfaces. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 104
TVs to computers, DVD players and similar devices. Drivers Program parts of the operating system. They adapt user program data to the specific formats required by I/O devices such as hard disk, printers, and monitors. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 105
10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 106
Intel Active Management Technology This technology permits diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 107
Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens AG issues a license key for each software that is protected by a license. License key USB flash drive The license key USB flash drive contains the authorizations or license keys required to enable protected SIMATIC software.
Page 108
Industrial Ethernet meets the requirements of industrial automation technology. Programmable controller The programmable controllers of the SIMATIC S7 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 109
This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...
Page 110
Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC377G Operating Instructions, 07/2022, A5E51366314-AB...