Chapter 7
Configuring 802.1X Port-Based Authentication
This example shows how to enable periodic re-authentication and set the number of seconds between
re-authentication attempts to 4000:
Switch(config)# dot1x re-authentication
Switch(config)# dot1x timeout re-authperiod 4000

Manually Re-Authenticating a Client Connected to a Port

You can manually re-authenticate the client connected to a specific port at any time by entering the
dot1x re-authenticate interface interface-id privileged EXEC command. If you want to enable or
diable periodic re-authentication, see the
This example shows how to manually re-authenticate the client connected to Fast Ethernet port 0/1:
Switch# dot1x re-authenticate interface fastethernet0/1
Starting reauthentication on FastEthernet0/1

Changing the Quiet Period

When the switch cannot authenticate the client, the switch remains idle for a set period of time, and then
tries again. The idle time is determined by the quiet-period value. A failed authentication of the client
might occur because the client provided an invalid password. You can provide a faster response time to
the user by entering smaller number than the default.
Beginning in privileged EXEC mode, follow these steps to change the quiet period:
Command
Step 1
configure terminal
Step 2
dot1x timeout quiet-period seconds
Step 3
end
Step 4
show dot1x
Step 5
copy running-config startup-config
To return to the default quiet time, use the no dot1x timeout quiet-period global configuration
command.
This example shows how to set the quiet time on the switch to 30 seconds:
Switch(config)# dot1x timeout quiet-period 30
78-11380-03
"Enabling Periodic Re-Authentication" section on page
Purpose
Enter global configuration mode.
Set the number of seconds that the switch remains in the quiet state
following a failed authentication exchange with the client.
The range is 0 to 65535 seconds; the default is 60.