Connecting Power
Secure port adapter interface cables and I/O cables by placing them through the cable-management
bracket.
Proceed to the
Connecting Power
This section provides the procedures for connecting AC-input and DC-input power to your Cisco 7201
router.
•
•
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
Never install an AC power module and a DC power module in the same chassis. Statement 1050
Warning
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
Warning
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than: 120 VAC, 20A U.S. (240 VAC, 10A international).
Statement 1005
Connecting AC-Input Power
This section provides instructions for connecting AC-input power.
The Cisco 7201 router has two of the same type of power supplies in power supply slot 1 and power
supply slot 2. The power supply slot numbers are on the chassis to the left of the left power supply, and
to the right of the right power supply. See
Cisco 7201 Installation and Configuration Guide
2-24
"Connecting Power" section on page 2-24
Connecting AC-Input Power, page 2-24
Connecting DC-Input Power, page 2-26
Chapter 2
to complete the installation.
Figure 2-20
Installing the Cisco 7201 Router
OL-11364-04