Site Requirement Guidelines
Each Cisco ASR 9001 Router is powered by only one type of input: AC or DC. A hybrid (AC+DC)
Caution
power configuration is not supported.
Proper grounding is necessary to avoid damage from lightning and power surges. See the
Caution
Supplemental Unit Bonding and Grounding Guidelines" section on page 1-19
requirements.
AC Powered Routers
AC power modules operate in the input range of 100 VAC to 240 VAC, 50 to 60 Hz and require a
minimum service of:
•
•
•
Each of the AC power inputs requires a separate dedicated branch circuit. For a list of the nominal and
acceptable value ranges for source AC power, see
Table 1-1
AC-input power supply modules.
Table 1-1
Locale
USA
Japan
Australia
Italy
Argentina
Switzerland
UK
China
South Africa/India
Europe
Israel
AC Power Cord Illustrations
This section contains the AC power cord illustrations, as described in
cord may be used with several power supplies.
Cisco ASR 9001 Router Hardware Installation Guide
1-12
15 A for operation in North America and Japan
10 A for international operation
13 A for operation in the UK
lists the AC-input power cord options, specifications, and Cisco product numbers for the
AC-Input Power Cord Options for ASR 9001 Router
Part Number
CAB-AC
CAB-L620P-C13-JPN
CAB-ACA
CAB-ACI
CAB-ACR
CAB-ACS
CAB-ACU
CAB-ACC
CAB-ACSA
CAB-9K10A-EU
SFS-250V-10A-IS
Table
A-5.
Table 1-1
also references power cord illustrations.
Length
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
8.2 feet (2.5 m)
Chapter 1
Preparing for Installation
"NEBS
for grounding
Power Cord
Reference
Rating
Illustration
15 A, 250 V
Figure 1-7
15 A, 250 V
Figure 1-8
10 A, 250 V
Figure 1-9
10 A, 250 V
Figure 1-10
10 A, 250 V
Figure 1-11
10 A, 250 V
Figure 1-12
13 A, 250 V
Figure 1-13
10 A, 250 V
Figure 1-14
10 A, 250 V
Figure 1-15
10 A, 250 V
Figure 1-16
10 A, 250 V
Figure 1-17
Table
1-1. Note that an AC power
OL-26701-01