Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly main-
tained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS &
CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE
FOR FUTURE USE.
1.
SAFETY
1.1.
GENERAL
Ensure the lamp is fully charged before initial use.
DO NOT turn the lamp on when it is being charged.
DO NOT shine directly into your, other person's or
animal's eyes.
DO NOT allow children to use the lamp.
DO NOT handle or move the lamp whilst it is being
charged.
DO NOT use the lamp if you suspect that the battery or
the lamp casing is damaged.
DO NOT leave battery in a discharged state, recharge
battery immediately. Before storage, fully recharge the
battery, subsequently recharge the battery at least once
every three months of non-use.
1.2.
ELECTRICAL SAFETY FOR USE OF CHARGER.
USE ONLY THE SUPPLIED CHARGER.
WARNING! It is the user's responsibility to read,
understand and comply with the following electrical
instructions:
You must ensure the risk of electric shock is minimised
by the installation of appropriate safety devices.
An RCCB (Residual Current Circuit Breaker) should be
incorporated in the main distribution board. We also
recommend that an RCD (Residual Current Device) is
used with all electrical products, particularly portable
equipment which is plugged into an electrical supply not
protected by an RCCB.
You must also read and understand the following instructions
concerning electrical safety.
1.2.1. The Electricity At Work Act 1989
requires all portable electrical appliances, if used on
business premises, to be tested by a qualified electrician,
using a Portable Appliance Tester (PAT), at least once a
year.
1.2.2. The Health & Safety at Work Act 1974 makes owners
of electrical appliances responsible for the safe condition
of the appliance and the safety of the appliance operator.
If in any doubt about electrical safety, contact a
qualified electrician.
1.2.3. You must ensure that you:
Inspect the charger plug, cable and connector for wear
and damage to ensure items are safe before connecting
to the mains power supply.
If worn or damaged DO NOT use.
Important: Check that the voltage marked on the charger
is the same as the power supply to be used.
DO NOT pull the charger plug from the mains socket by
the lead.
WARNING! DO NOT use any other type of charger with
this product, other than the supplied mains charger.
Failure to observe this warning could result in
injury and or fire and will invalidate the warranty.
DO NOT try to take the charger apart.
DO NOT get the charger wet, or use in wet, damp
conditions (for indoor use only).
1.2.4. Ensure that the insulation on all cables and on the
appliance is safe before connecting it to the power
supply. See 1.2.1. and 1.2.2. and use a Portable
Appliance Tester.
INSTRUCTION MANUAL FOR:
CORDLESS 30 + 5LED RECHARGEABLE
INSPECTION LAMP
MODEL No.
1.2.5. Ensure that cables are always protected against short
circuit and overload.
1.2.6. DO NOT use worn or damaged cables, plugs or
connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician.
When a BS 1363/A UK 3 pin plug is damaged, cut the
cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK
only).
a) Connect the GREEN/YELLOW earth wire to the
earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral
terminal 'N'.
d) After wiring, check that there are no bare wires, that
all wires have been correctly connected, that the
cable outer insulation extends beyond the cable
restraint and that the restraint is tight.
Double insulated products, which are always marked
with this symbol
neutral (blue) wires only. To rewire, connect the wires as
indicated below.
DO NOT connect either wire to the earth terminal.
Blue
Neutral
Wire
1.3
Battery Safety
WARNING! To reduce the risk of burns or fire:
DO NOT Attempt to open, disassemble, modify or
service the battery pack.
DO NOT Crush, puncture, short external contacts or
dispose of in fire or water.
DO NOT Expose to temperatures above 60°C (140°F).
Replace only with the battery pack designated for this
product.
Recycle or dispose of used battery as stipulated by local
regulation.
If the electrolyte in the cells gets on your skin, thoroughly
wash with soap and water. If it gets in your eyes, rinse
thoroughly with cool water and seek immediate medical
attention
Original Language Version
LED3009
, are fitted with live (brown) and
Yellow & Green
Earth Wire
Brown
Live
Wire
Cable
Restraint
FUSE RATING
3 AMP
LED3009
Issue: 2 - 15/03/10

Advertisement

loading

Summary of Contents for Sealey LED3009

  • Page 1 LED3009 MODEL No. Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly main- tained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS &...
  • Page 2 To obtain parts please email sales@sealey. co.uk or phone 01284 757500. Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme.