Power Supply Overview
The handle of the AC unit is at the bottom of the unit.
Figure 4-12: AC Power Module
The handle of the DC unit is at the top of the unit.
Figure 4-13: DC Power Module
LEDs
The following LEDs are used to monitor the functioning of the power supply units:
•
•
On both the AC-input and DC-input power supplies, the IN LED iis used to monitor the voltages
received by the platform from the power source. If the input voltages are within normal operating
ranges, the green IN LED is illuminated. If the input voltages are above or below normal ranges,
the IN LED is not illuminated.
On both the AC-input and DC-input power supplies, the OK LED is used to monitor the power
supply DC output voltages used to power the platform. The normal operating ranges for the 12
VDC output voltage is between 11.9V and 12.1V. If the output voltages are within normal
operating ranges, the green OK LED is illuminated. If the 12 VDC output voltages are above
(more than 12.1V) or below (less than 11.9V) normal ranges, the OK LED is not illuminated.
The Power A and Power B LEDs on the front panel indicate whether the corresponding power
supply unit is functioning normally.
Cisco SCE 2000 4/8xFE Installation and Configuration Guide
4-12
On the power supply unit (both AC-input and DC-input):
IN LED (green)
•
OK LED (green)
•
On the Front Panel (on page 2-1):
Power LED — There are two Power LEDs on the front panel (Power A and Power B), one
•
LED corresponding to each power supply unit
Chapter 4
Installation and Maintenance
OL-7826-05