INSTALLATION INSTRUCTIONS
CHECKING ELECTRICAL
CONNECTIONS
Confirm the appliance is correctly connected by
switching on and observing the various oven
functions indicators.
The electronic timer will flash on and off.
CONNECTING TO A HOB OR
COOKER POINT
Either follow in general terms the instructions for
connecting to the terminal block or refer to the
hob suppliers installation instructions.
Feed the cable through the cabinet and
arrange to route the cable away from
the appliance.
NOTE: HOUSE CIRCUIT
Earth leakage / continuity tests must be carried
out before the appliance is connected to the
mains supply and re-checked after fitting.