hit counter script
Download Print this page
Honeywell Ex-Or MLS2021DF Installation And Commissioning Instructions
Honeywell Ex-Or MLS2021DF Installation And Commissioning Instructions

Honeywell Ex-Or MLS2021DF Installation And Commissioning Instructions

Digital gold pir detector with regulating photocell

Advertisement

Quick Links

MLS2021DF & MLS2021DSM for DSI ballasts
MLS2021DALIF & MLS2021DALISM for DALI ballasts
Digital Gold PIR Detector
with regulating photocell
MLS2021DF
MLS2021DALIF
MLS2021DSM
MLS2021DALISM
Installation and Commissioning
Instructions
Note: QuickSet Pro required for commissioning
1

Advertisement

loading

Summary of Contents for Honeywell Ex-Or MLS2021DF

  • Page 1 MLS2021DF & MLS2021DSM for DSI ballasts MLS2021DALIF & MLS2021DALISM for DALI ballasts Digital Gold PIR Detector with regulating photocell MLS2021DF MLS2021DALIF MLS2021DSM MLS2021DALISM Installation and Commissioning Instructions Note: QuickSet Pro required for commissioning...
  • Page 2 Digital Gold PIR Detector with Regulating Photocell Please note that UltraLite versions of these detectors (suffix CWL7) do not offer MLS functionality and cannot be connected using MLS cable. Only suitably qualified personnel should install this equipment. This is a high-performance, communicating presence detector which can be used as part of a full Ex-Or MLS Digital Managed Lighting System or as a stand-alone unit.
  • Page 3 MLS2021D These Connections are Using OneSwitch, MLS*, Switched and Polarity-Free Digital Outputs * UltraLite-version detectors (suffix CWL7) Digital do not offer MLS functionality and cannot Output be connected using MLS cable. LOAD VOLT- (MAX 6 AMPS) FREE OUTPUT MLS Bus Connection (Some MLS devices require that polarity be maintained) LIVE...
  • Page 4 Commissioning The units are supplied with the factory default settings shown below which make further commissioning unnecessary in many applications. To make use of the programmable settings, an infrared commissioning tool is required (QuickSet Pro). A ten-second time delay is selectable from programmer to aid commissioning. Sensitivity to Movement While the factory settings will be correct for many applications, the sensitivity can be adjusted if required.
  • Page 5 Photocell Control i) Regulating Photocell Regulating photocell control tries to maintain a constant level of total illumination in the space controlled by dimming and brightening the controlled luminaires to compensate for changes in illumination from other sources. With the photocell configured as DISABLED the Regulating Control module is influenced only by the BRIGHT-OUT setting.
  • Page 6 Programming the Photocell Set-points (Continued) Tip: Turn the lights off with the QuickSet Pro (UTILITIES / LIGHTSPOT/MLS/LCM / IR REMOTE / HC5) to measure the perceived light level with no contribution from the controlled lighting. Alternatively the SET-POINTS can be configured semi-automatically; i) The Primary Interest is the Regulating Control Output.
  • Page 7 OneSwitch OneSwitch Dimming affords local control to the end-user whereby a simple, momentary, push-to-make wall switch can be used to raise or lower the lighting level or toggle the output of the unit ON or OFF. A short press (less than 1 second) toggles all outputs from both OFF to both ON or from either ON to both OFF.
  • Page 8 MATERIAL: Flame retardant PC/ABS WEIGHT: 210g (flush version), 187g (surface version) IP RATING: 3X OPERATING TEMPERATURE: 0 C to 40 C Honeywell Ex-Or St. Marks Court, North Street, At the end of their useful life the packaging and product Horsham, West Sussex, RH12 1BW, UK should be disposed of via a suitable recycling centre.

This manual is also suitable for:

Ex-or mls2021dsmEx-or mls2021dalifEx-or mls2021dalism