KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 1 Safety Precaution 1.1. For Service Technicians ICs and LSIs are vulnerable to static electricity. When repairing, the following precautions will help prevent recurring malfunctions. 1. Cover the plastic parts boxes with aluminum foil and ground them. 2. Ground the soldering irons.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 4.2. Circuit Operation (Base Unit) 4.2.1. Outline Base Unit consists of the following ICs as shown in Block Diagram (Base Unit) (P.6). • DECT BBIC (Base Band IC): IC7 - Handling all the audio, signal and data processing needed in a DECT base unit...
Page 8
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 4.2.2. Power Supply Circuit The power is supplied to the DECT BBIC, RF Module, EEPROM and Charge Contact from AC Adaptor (+6.5 V) as shown in Fig.101. The power supply is as follows; • DECT BBIC (IC7): CN2 (+6.5 V) → IC1 → Q9 → IC7 CN2 (+6.5 V) →...
Page 9
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 4.2.3. Telephone Line Interface <Function> • Bell signal detection • Clip signal detection • ON/OFF hook circuit Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection: In the standby mode, Q3 is open to cut the DC loop current and decrease the ring load.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 4.4. Circuit Operation (Handset) 4.4.1. Outline Handset consists of the following ICs as shown in Block Diagram (Handset) (P.10). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD) •...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 5 Location of Controls and 5.2. Display Components 5.1. Controls 5.1.1. Base Unit 6 Installation Instructions 6.1. Setting up the Base Unit 6.1.1. Connecting the AC adaptor and 5.1.2. Handset telephone line cord...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 6.3. Battery 6.1.2. If you subscribe to a DSL service 6.3.1. Battery installation/replacement 6.2. Setting up the Handset 6.2.1. Connecting the AC adaptor...
Page 17
Battery charge 6.3.3. Battery level 6.3.4. Panasonic battery performance Note for service: The battery strength may not be indicated correctly if the battery is disconnected and connected again, even after it is fully charged. In that case, by recharging the battery as mentioned above, you will get a correct indication of the battery strength.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 7.2. Registering a Handset 7.2.1. Deregistering a handset 7.3. Copying Handset Phonebook Items You can copy one or all of the phonebook items from one handset to another.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 8 Service Mode 8.1. Engineering Mode 8.1.1. Base Unit...
Page 27
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S Frequently Used Items (Base Unit) ex.) Items Address Default Data New Data Remarks Frequency 00 01 Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may 00 10~00 14 Given value cause serious damage to the computer system.
Page 29
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Battery Low 00 04 (*2) Frequency 00 01 00 10~00 14 Given value Note: (*1) When you enter the address or New Data, please refer to the table below.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 8.2. Copying Phonebook Items when Repairing You can copy the handset phonebook to another (compatible Panasonic) handset. This will help to save the original phonebook data which the customer has registered. Refer to the following procedures.
Page 31
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S Note: • If the max number of handsets are already registered to the base unit, a new handset cannot be registered. • To register the handset, refer to Registering a Handset (P.20). • ToTo cancel the handset, refer to Deregistering a handset (P.20).
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 8.3. How to Clear User Setting Units are reset to the Factory settings by this operation (Erase recorded Voice messages, stored Phone numbers, Caller list and etc.) Note: • The reset menus differ depending on the following operations. • This operation should not be performed for a usual repair.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9 Troubleshooting Guide 9.1. Troubleshooting Flowchart Cross Reference: Check Power (P.34) Bell Reception (P.43) Check Battery Charge (P.35) Check Link (P.36) Check Handset Transmission (P.43) Check Handset Reception (P.43) Signal Route (P.13) Check Caller ID (P.43) Check TAM Operation (P.44)
Page 34
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.1. Check Power 9.1.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (*1) Cross Reference: Note: Power Supply Circuit (P.8) (*1) Refer to Specifications (P.5) for part number and supply voltage of AC Adaptor. 9.1.1.2. Handset Cross Reference:...
Page 35
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.2. Check Battery Charge 9.1.2.1. Base Unit Cross Reference: Charge Circuit (P.11) 9.1.2.2. Handset Cross Reference: Check Power (P.34) Charge Circuit (P.11) 9.1.2.3. Charger Unit Cross Reference: Charge Circuit (P.11)
Page 36
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.3. Check Link 9.1.3.1. Base Unit Cross Reference: Check Point (Base Unit) (P.45) Power Supply Circuit (P.8) Check the RF part (P.38)
Page 37
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.3.2. Handset Cross Reference: Check Point (Handset) (P.45) Power Supply Circuit/Reset Circuit (P.11) Check the RF part (P.38)
Page 38
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.4. Check the RF part 9.1.4.1. Finding out the Defective part After All the Checkings or Repairing 1. Re-register the checked Handset to the checked Base Unit, and Regular HS to Regular BU. Note: If you need to register a handset, refer to Registering a Handset (P.20)
Page 39
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.4.2. RF Check Flowchart Each item (1 ~ 6) of RF Check Flowchart corresponds to Check Table for RF part (P.40). Please refer to the each item. Note: (*1) Base unit - refer to (D) of Check Point (Base Unit) (P.45) Handset - refer to (F) of Check Point (Handset) (P.45)
Page 40
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.4.3. Check Table for RF part Item BU (Base Unit) Check HS (HandSet) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). HS, BU Mode: [Normal mode] 2.
Page 41
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.4.4. TEST RANGE Check Circuit block which range is defective can be found by the following check. Item BU (Base Unit) Check HS (Handset) Check Range Confirmation TX TEST 1. Register Regular HS to BU (to be checked). 1. Register HS (to be checked) to Regular BU.
Page 42
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.4.5. RF-BBIC Interface Signal Wave Form SYEN SYCL SYDA...
Page 43
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.5. Check Handset Transmission 9.1.6. Check Handset Reception Cross Reference: Signal Route (P.13) Cross Reference: How to Check the Handset Speaker or Receiver (P.65). Signal Route (P.13) 9.1.7. Check Caller ID Cross Reference: Signal Route (P.13) 9.1.8. Bell Reception 9.1.8.1.
Page 44
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.1.9. Check TAM Operation A) How to change the Auto Disconnect activation (time) Some Telephone Company lines (fiber or cable) ON Hook and OFF Hook voltages are lower than conventional lines, which may cause a malfunction of Auto Disconnect detection. To solve this problem, try changing the Auto Disconnect activation through the procedures below.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.2. Troubleshooting by Symptom (Base Unit and Charger Unit) 9.2.1. Check Point (Base Unit) Please follow the items below after repairing. Note: After the measuring, suck up the solder of TP. *: PC Setting (P.56) is required beforehand. The connections of simulator equipments are as shown in Adjustment Standard (Base Unit) (P.58).
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.4. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
Page 47
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.4.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.5. How to Replace the LLP (Leadless Leadframe Package) IC 9.5.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 49
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 9.5.4. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. 2. Place the solder a little on the land where IC pins are to be attached, then place the IC.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11 Measurements and Adjustments 11.1. The Setting Method of JIG (Base Unit) 11.1.1. Preparation 11.1.1.1. Equipment Required • Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm). Hewlett Packard, 53131A is recommended.
Page 57
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.1.2.2. Batch file Settings Note: • “****” varies depending on the country. 11.1.2.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.2. Adjustment Standard (Base Unit) When connecting the simulator equipment for checking, please refer to below. 11.2.1. Component View R103 R152 C108 C105 C110 C106 C103 C107 C109 C104 C119 C120 IC10 C121 C128 C126 R109 R151 R110 C127...
Page 59
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.2.2. Flow Solder Side View Note: (A) - (D) is referred to Check Point (Base Unit) (P.45) (*1) is referred to No.3 of Check Table for RF part (P.40)
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.3. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 11.3.1. Flow Solder Side View DC POWER 6.5 V GND (TP4) /2 W Digital Volt Meter...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.4. The Setting Method of JIG (Handset) 11.4.1. Preparation 11.4.1.1. Equipment Required • Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm). Hewlett Packard, 53131A is recommended. • DC power: it must be able to output at least 1 A current under 2.4 V for Handset.
Page 62
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.4.2.2. Batch file Settings Note: • “*****” varies depending on the country. 11.4.2.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.5. Adjustment Standard (Handset) When connecting the simulator equipment for checking, please refer to below. 11.5.1. Component View Note: (A) - (F) is referred to Check Point (Handset) (P.45) (*1) is referred to No.3 of Check Table for RF part (P.40)
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.6. Things to Do after Replacing IC or X'tal Cautions: Some of the content on this page may not apply to models from some countries. The contents below are the minimum adjust- ments required for operation. 11.6.1. Base Unit Before making the following adjustment, ensure you have carried out PC Setting (P.56) in The Setting Method of JIG (Base...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 11.7. How to Check the Handset Speaker or Receiver 1. Prepare the digital voltmeter, and set the selector knob to ohm meter. 2. Put the probes at the speaker terminals as shown below. 11.8. Frequency Table (MHz) BASE UNIT...
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 12 Schematic Diagram 12.1. For Schematic Diagram 12.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology.
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.55). (*2) The rechargeable Ni-MH battery HHR-4DPA (Capacity: up to 550 mAh) is available through sales route of Panasonic. (*3) Attach the spacer (No. 122) to the exact location described above.
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 15.5. Replacement Part List Ref. Part No. Part Name & Description Remarks 1. RTL (Retention Time Limited) PQKE10474Y1 CASE, CHARGE TERMINAL PS-HB Note: PQBC10497Z1 BUTTON, MESSAGE AS-HB The marking (RTL) indicates that the Retention Time PQSX10343Z KEYBOARD SWITCH, RUBBER...
Page 95
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks ERJ3GEYJ104 100K ECUE1A104KBQ ERJ3GEYJ474 470K ECUV1H221JCV 220P ERJ2GEJ560X ECUV1H221JCV 220P ERJ3GEYJ820 ECUE1C223KBQ 0.022 ERJ3GEYJ821 ECUE1A104KBQ ERJ3GEYJ104 100K ECUV1C104KBV ERJ2GEJ102 ECUE1A104KBQ ERJ3GEYJ104 100K ECUE1A104KBQ...
Page 96
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S 15.5.1.3. Operational P.C.Board Parts Ref. Part No. Part Name & Description Remarks LED10 B3ACB0000134 (IC FILTERS) Ref. Part No. Part Name & Description Remarks J0JCC0000287 IC FILTER J0JCC0000275 IC FILTER PCB2 PQWP2TG1032H OPERATIONAL P.C.BOARD ASS'Y (RTL) J0JCC0000276 IC FILTER...
Page 97
ECUE1H100DCQ ECUE1H390JCQ Note: ECUE1H102KBQ 0.001 (*1) You can download and refer to the operating instruc- ECUE1H100DCQ tions (Instruction book) on TSN server. ECUE1H100DCQ ECUE1H100DCQ 15.5.4.1. KX-TG1032S ECUE1H100DCQ ECUE1H471KBQ 470P ECUE1H100DCQ Ref. Part No. Part Name & Description Remarks ECUV1A106ZF ECUE1H100DCQ...
Page 98
KX-TG1032S/KX-TG1033S/KX-TG1034S/KX-TGA101S Ref. Part No. Part Name & Description Remarks P105 PQPK15670Z GIFT BOX P106 PQXDDS400-8 MAGNET ELECTRIC TRANSDUCER, SECURITY TAG 15.5.4.3. KX-TG1034S Ref. Part No. Part Name & Description Remarks A201 PQLV207V AC ADAPTOR (for Base Unit) A202 PQLV209V AC ADAPTOR (for Charger Unit)