Page 2
Motorola BCS. Motorola BCS assumes no responsibility for any errors that may appear in this document nor does it make express or implied warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
Page 3
Equipment returned for repairs shall be packed securely by You and shall be shipped prepaid, together with a statement setting forth the claimed defect, to Motorola BCS’ designated repair facility. Motorola BCS shall prepay and bear the cost of freight for shipments to You of repaired or replaced Encoders.
Factory preset and user modifiable configurations • Flexible input and output options • This product manual provides critical information to set up and configure the SE-1010 / SE- 2000 Encoder. Please read this manual before starting installation. Document Number: 504834-001...
Single Channel Encoder VIDEO ONLINE AUDIO 1 ENTER FAULT AUDIO 2 SE - 2000 Single Channel Encoder VIDEO ONLINE AUDIO 1 ENTER FAULT AUDIO 2 SE-2000 Single Channel Encoder Ethernet Element Manager SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
“Connectors and Required Cables” on page 31. Inventory Verify that the shipping carton contains the following items: An SE-1010 or SE-2000 encoder with attached mounting brackets • SE-1010 / SE-2000 Encoder Product Manual (this manual) •...
DHEI Out Note: For applications that use the Analog Video In Note: Clip the supplied cord connector, attach a 75–ohm termination to the Analog retainer on the two standoffs. Video Loop Thru connector. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Basic Operation Navigation When the encoder powers up, the Liquid Crystal Display (LCD) displays the software version: • S E - 2 0 0 0 V e r 1 . 0 0 / 1 . a M o t o r o l a B C S Use the front panel’s four arrow and ENTER buttons to navigate the LCD’s two 40-character lines.
> indicates that you can press the right ( > ) arrow button. | (vertical line) indicates that you can press the up ( /\ ) or down ( \/ ) arrow button. E indicates that you can press the ENTER button. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Menu Description The LCD screen’s top line is named the Menu Line and it displays all the menu options. The bottom line is named the Edit Line and it displays the navigational legend and all encoder options. Each of the nine menus has a Menu Line and Edit Line. The Preset menu has the following eight options: Preset Name...
SE Encoder Factory Presets Table 1 shows the encoder’s 30 factory-defined presets. To restore the presets to their default settings, see “Reset Menu” on page 26. Table 1 Default Settings For Factory-defined Presets Presets Menu : Option 8 − 30 Video : In NTSC NTSC...
Menus This chapter contains diagrams of SE encoder menus and describes the options available to view and/or change. The following navigational diagram shows the menu hiearchy and a page number where each menu is described in detail. Preset Name Video Audio1 Audio2 VBI See page 12 Transport Output...
Use the left arrow button to move the cursor backward. Note: Names can be up to 28 characters. To insert a space, choose the underscore character ( _ ). 4. After changing the name, press the ENTER button. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Ratio aspect ratio) or 16:9 (widescreen aspect ratio). Format SE-1010 Only The LED displays 4:2:0 (for standard distribution feeds). This value is read-only and cannot be changed. SE-2000 Only Select the desired MPEG profile video: 4:2:0 (for standard distribution feeds) or 4:2:2 (for high-quality contribution feeds).
(elementary stream bitrate). The options are 96, 112, 128, 160, 192, 224, 256, 320, 384, 448, 512, 576, and 640. For more details, see “Audio Processing” at the bottom of page 34. (Audio1/Audio2 options are continued on the next page.) SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Page 21
Option Definition Description Language Language Use this option to select a 3-character audio language. For example, select eng (English) for Audio1 and spa (Spanish) for Audio2. Use the up and down arrow buttons to access: eng, spa, fre, ita, ger, and chn. Then, to access any of the other languages listed below, use the up and down arrow buttons to change all three characters.
22) of field one (1) are enabled for Type:WST 1/22 WST. Type:WST 2/07 World Standard Use this option to specify which lines (07 through Teletext through 22) of field two (2) are enabled for Type:WST 2/22 WST. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
PID Options To view or change the Packet Identification (PID) parameter in the Preset menu, press the right arrow ( > ) button until the pointer is in front of the PID option. Table 6 describes each PID option. • P r e s e t A u d i o 1 A u d i o 2...
Use this option to set the Transport Stream ID number within the Stream system information. Use the up and down arrow buttons to set Identifier each of the five digits. Enter a value from 00001 to 65535. The default is 00001. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
ServiceName Menu Making changes to this menu is only necessary if Network Type (described on page 20) is set to DVB-S, DVB-C, or DVB-T. These settings apply to the SE encoder, rather than to an individual preset. Use the Service Information menu to view or change options. Table 8 describes each option.
Polarization polarization: Linear Horiz, Linear Vert, Circular Left, or CircularRight. The default is Linear Horiz. ModQPSK Modulation During typical standalone mode, Modulation Type is read- Type only and is set to QPSK. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Table 10 DVB-C (Cable) Options Option Definition Description Freq Cable Use the up and down arrow buttons to set the cable Frequency frequency (0000.0000 to 9999.9999 MHz). The default is 0312.0000 MHz. Rate Transport Use the up and down arrow buttons to set the desired Symbol Rate transport symbol rate (000.0000 to 999.9999 Msps).
4. Use the up or down arrow button to choose either Local or Remote and press ENTER. When the operator uses the arrow buttons to exit the Control menu, the encoder will return to the locked state. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
IP Addrs The IP Addrs option has three editable values: IP Address, SubnetMask, and Gateway IP. To view a specific value, go to the Control menu, use the arrow buttons to place the cursor (>) in front of IP Addrs, and press ENTER. Now use the right and left arrow buttons to display the value.
Select ON to replace the external audio signal on Audio2 with a 1 kHz test tone that is generated by the encoder. Select OFF to stop the test tone and replace it with the external audio signal. The default is OFF. SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Status Log Menu Use the encoder’s Status Log menu to view messages. For more details, see “Log Messages” on page 27. To view the log message 1. Navigate to the SE-Status Log menu as shown below. • > S E – 2 0 0 0 S T A T U S L O G C L E A R...
To exit this LCD screen without resetting the encoder, press the left arrow button and then the down arrow button. Software Version This menu displays the product name (SE-1010 or SE-2000) and the software version number. • S E - 2 0 0 0 V e r 1 .
Log Messages Log messages are categorized by two levels of severity: Warnings are non critical faults. • Faults (shown in bold in Table A-1 on page 28) activate the Form_C circuit on the back • panel and light up the Fault LED on the front panel. Table A-1 on page 28 shows the four categories of log messages: Packet Processor •...
(Power-on self test) Form_C AP_2 Communication Error No AP_2 Faults/Warnings (This means no Audio2 faults or warnings exist.) Miscellaneous Video Input Sync-Loss Video Input Sync (This means video input sync has been reacquired.) SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Table B-1 Connector Pinouts Connector Signal Common N. C. (Normally Closed) N. O. (Normally Opened) Form_C (Unused) (Unused) (Unused) (Only For Motorola BCS Support Personnel) (Unused) (Unused) (Unused) SHLDGND (Unused) (Unused) 11 12 13 14 15 (Unused) SIGND DHEI SENSEL...
471988-001 Form_C Connector (Provided with the encoder) Alarm 469047-001 Analog Audio Connector [Phoenix Type] (Provided with the encoder) Audio Table C-2 lists required cables for the SE-1010 and SE-2000. Table C-2 Required Cables Type Length Description 0 to 100 m...
Specifications The following tables provide all SE-1010 and SE-2000 specifications. Transport Output Connectors DVB-ASI BNC, Female (x2, Main and Monitor) BNC, Female (x1) DHEI (29.26 MHz) HD-15, Female (x1) Input Video Connectors Serial Digital 4:2:2 Per BNC (75-ohm), Female (x2, Input and Loop)
Page 40
32 to 96 K samples per second Sample Rates (Rate converted to 48 K samples per second) Compression Rates 96, 112, 128, 160, 192, 224, 256, 320, and 384 kbps 448, 512, 576, and 640 kbps (AC3 only) SE-1010 / SE-2000 Encoder Product Manual, Version 1.0...
Page 41
Program Processing Value PES/Transport Alignment Video PID 32 to 8187, Default 32 (Decimal) Audio PID (Channel 1) 32 to 8190, Default 33 (Decimal) Audio PID (Channel 2) 32 to 8190, Default 34 (Decimal) PMT PID 32 to 8190, Default 35 (Decimal) WST PID 32 to 8190, Default 36 (Decimal) Allow PID Contention...