hit counter script
Motorola LD-W-1 Manual
Motorola LD-W-1 Manual

Motorola LD-W-1 Manual

Locomotive decoder for ac and dc engines

Advertisement

Quick Links

Lokdecoder für Wechselstrommotoren
Locomotive Decoder for AC engines
Décodeur pour locomotive avec moteur alternatif
Locdecoder voor wisselstroommotoren
Art.-Nr. 22-01-015 C 21 27 00
Lokdecoder für Gleichstrommotoren
Locomotive Decoder for DC engines
Décodeur pour locomotive avec moteur continu
Locdecoder voor gelijkstroommotoren
Art.-Nr. 22-01-016 C 21 27 96
LD-W-1
Motorola-Format
Motorola-Format
Format-Motorola
Motorola-format
LD-G-1
Motorola-Format
Motorola-Format
Format-Motorola
Motorola-format
n
n
n
n
n
n
n
n
n
n
Anleitung
n
Manual
n
Mode d´emploi
n
Handleiding
n
n
n

Advertisement

Table of Contents
loading

Summary of Contents for Motorola LD-W-1

  • Page 1 LD-W-1 Lokdecoder für Wechselstrommotoren Motorola-Format Locomotive Decoder for AC engines Motorola-Format Décodeur pour locomotive avec moteur alternatif Format-Motorola Locdecoder voor wisselstroommotoren Motorola-format Art.-Nr. 22-01-015 C 21 27 00 LD-G-1 Anleitung Lokdecoder für Gleichstrommotoren Manual Motorola-Format Locomotive Decoder for DC engines Mode d´emploi...
  • Page 2 © 07/2002 Tams Elektronik GmbH Alle Rechte, insbesondere das Recht der Vervielfältigung und Verbreitung sowie der Übersetzung vorbehalten. Vervielfältigungen Reproduktionen jeglicher Form bedürfen schriftlichen Genehmigung Deutsch durch die Tams Elektronik GmbH. Technische Änderungen vorbehalten. English Français © 07/2002 Tams Elektronik GmbH rights reserved.
  • Page 3: Table Of Contents

    LD-G-1 / LD-W-1 Table of contents How to use this manual Intended use Safety instructions EMC declaration Information: Motorola I and Motorola II format Operation overview Technical specifications Checking the package contents Required tools and consumables Safe and correct soldering...
  • Page 4: How To Use This Manual

    It is designed for the mounting in a model railway locomotive with d.c. motor (LD-G-1) resp. a.c. motor (LD-W-1). It evaluates the Motorola format data sent by the digital central unit to its address. The decoder controls the vehicle performance (velocity, direction of travel, acceleration), switches the lighting and four further optional functions.
  • Page 5: Safety Instructions

    English LD-G-1 / LD-W-1 Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries. Watch out for sharp edges when you pick up the PCB. Visibly damaged parts can cause unpredictable danger. Do not use damaged parts: recycle and replace them with new ones.
  • Page 6 LD-G-1 / LD-W-1 English Fire risk Touching flammable material with a hot soldering iron can cause life- threatening fire, burns and toxic smoke. Connect your soldering iron or soldering station only when actually needed. Use the correct soldering iron or station and never leave a hot soldering iron or station unattended.
  • Page 7: Emc Declaration

    Motorola II format. This limits its use in Motorola I format. Since data of the auxiliary functions F1 to F4 sent in Motorola I Format cannot be evaluated by the locomotive decoder, it is not possible to switch these functions on or off when using Motorola I format.
  • Page 8: Operation Overview

    English Operation overview The decoder is designed for operation in Motorola I or II format and can be adjusted to one of 255 adresses. It evaluates the digital data sent by the central unit to its address and transmitts it to the locomotive.
  • Page 9: Technical Specifications

    By attaching a solder bridge the shunting gear can be deactivated permantly. Restrictions in Motorola I format The auxiliary functions F1 to F4 are not available in Motorola I format. It is possible to control one accessory via the function "function" according to the direction of travel.
  • Page 10: Required Tools And Consumables

    LD-G-1 / LD-W-1 English Required tools and consumables Make sure you have the following tools, equipment and materials ready for use: § a heat-resistant mat and a soldering iron stand with tip-cleaning sponge § a small side cutter and wire stripper §...
  • Page 11: English Ld-G-1 / Ld-W

    English LD-G-1 / LD-W-1 Performing a visual check Damaged materials can cause injury. Parts damaged during transit can also be dangerous.Check the module for damage, missing parts or poor soldering. If you find damage, return the module for exchange. Mounting the locomotive decoder Open the locomotive housing.
  • Page 12 LD-G-1 / LD-W-1 English fig. 3a) or you must connect the second side of the lamps according to fig. 3b to the return conductor (point X3 on the front of the decoder). Connect other accessories (e.g. smoke generator, cab lighting), which are switched by the functions F1 to F4, to the points X7 to X10 (front of the decoder).
  • Page 13: Setting The Locomotive Decoder

    English LD-G-1 / LD-W-1 You can connect several LEDs in parallel to each output. In this case every LED must have a series resistor of its own. If you connect several LEDs to one output in series, only one series resistor is needed. The number of LEDs connected in series to one output depends on the digital voltage.
  • Page 14 LD-G-1 / LD-W-1 English § Standard or second velocity characteristics § Shunting gear active or inactive § Fast, medium or slow acceleration and brake delay The setting of the delay can be combined with any setting of the velocity characteristic and the shunting gear. The setting is made by attaching solder bridges to X17 (on the front of the decoder, underneath the IC U1) and to X20 (on the front of the decoder, to the left of IC U1).
  • Page 15: Operation

    English LD-G-1 / LD-W-1 The solder pad "4" is identical with connecting point X18. If for one address two connections to solder pad 4 are given, two connections to point X18 must be made. Caution: Use a soldering iron with a small tapered point and max. 30 Watt to make the solder bridges.
  • Page 16: Faq

    LD-G-1 / LD-W-1 English § Parts are getting too hot and/or start to smoke. Disconnect the system from the mains immediately! Possible cause: one or more connections are soldered incorrectly. à Check the connections. Possible cause: The connection of the motor is connected to locomotive ground.
  • Page 17: Certification

    English LD-G-1 / LD-W-1 relevant papers. Domestic appliances assembled from a kit are deemed industrial products and must comply with health and safety regulations. Certification This product conforms with the EC- directive 89/336/EWG on electromagnetic radiation and is therefore CE certified. Conditional warranty This product is guaranteed for two years.
  • Page 18 LD-G-1 / LD-W-1 Einstellung der Adresse / Adjusting the address Réglage de l’adresse / Instellen van het adres Beispiel: Einstellung der Adresse "107" Example: Adjusting the address "107" Exemple: Réglage de l´adresse "107" Voorbeeld: Instellen van adres "107" Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address...
  • Page 19 LD-G-1 / LD-W-1 Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address Plots d´une rangé Address Plots d´une rangé Adresse Soldeerpunten Adresse Soldeerpunten Adres Adres X14 X16 X15 X13 X14 X16 X15 X13 -- 2-3 Seite - Page - Page - Pagina 69...
  • Page 20 LD-G-1 / LD-W-1 Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address Plots d´une rangé Address Plots d´une rangé Adresse Soldeerpunten Adresse Soldeerpunten Adres Adres X14 X16 X15 X13 X14 X16 X15 X13 1-2 1-2 Seite - Page - Page - Pagina 70...
  • Page 21 LD-G-1 / LD-W-1 Adresse Lötfeld - Soldering field Adresse Lötfeld - Soldering field Address Plots d´une rangé Address Plots d´une rangé Adresse Soldeerpunten Adresse Soldeerpunten Adres Adres X14 X16 X15 X13 X14 X16 X15 X13 Seite - Page - Page - Pagina 71...
  • Page 22 LD-G-1 LD-G-1 LD-G-1 Schaltplan Circuit diagram Schéma de principe Schakelschema Fig. 1 n n n Ausgänge Outputs Sorties Uitgangen Seite - Page - Page - Pagina I Seite - Page - Page - Pagina I...
  • Page 23 LD-W-1 LD-W-1 LD-W-1 Schaltplan Circuit diagram Schéma de principe Schakelschema Fig. 2 n n n Ausgänge Outputs Sorties Uitgangen Seite - Page - Page - Pagina II Seite - Page - Page - Pagina II...
  • Page 24 LD-G-1 / LD-W-1 LD-G-1 / LD-W-1 Anschlußplan 1 Connections 1 Plan de raccordement 1 Aansluit plan 1 Fig. 3a / 3b n n n Seite - Page - Page - Pagina III Seite - Page - Page - Pagina III...
  • Page 25 LD-G-1 / LD-W-1 LD-G-1 / LD-W-1 Anschlußplan 2 Connections 2 Plan de raccordement 2 Aansluit plan 2 Fig. 4 / 5 n n n Seite - Page - Page - Pagina IV Seite - Page - Page - Pagina IV...
  • Page 26 Aktuelle Informationen und Tipps: Information and tips: Informations et conseils: Actuele informatie en tips: http://www.tams-online.de Garantie und Service: Warranty and service: Garantie et service: Garantie en service: Tams Elektronik GmbH Sievertstraße 22 D-30625 Hannover fon: 0049 (0)511 / 55 60 60 fax: 0049 (0)511 / 55 61 61 e-mail: modellbahn@tams-online.de...

This manual is also suitable for:

Ld-g-1

Table of Contents