Enter Programming There are 2 steps to unlock the Programming Mode Programming Mode: Display: Pro Display: do (dose) Press the cleaning and Press & Hold the GEAR button First item in the for 3 seconds continuous buttons programming list Press & hold the continuous button first, then the cleaning button Hold both for 3 seconds...
Page 7
Programming Programming gear to scroll through list...
Programming Options Scroll Through list Select Function Toggle Settings: OFF/ON Enter sub-Menu Change Value: + /-...
Page 9
Adjust Steam Pressure When “ON” Press Stars to enter Programming Scroll to Pressure and 1 . 1 Toggle between press Stars to enter OFF & ON if needed Normal setting is ON Adjust bar setting Press & Hold the GEAR button on with lower keys G1 for 3 seconds to Save and Exit...
Page 17
Change Group Gasket Remove Group Cover Remove Both Screws Lower Cover Unplug connector Careful! Don’t pull wires...
Page 18
Change Group Gasket Easy-Lock Spring Easy-Lock O-ring Group Gasket Holder Group O-ring Group Gasket (Group Compactor) Water Diffuser Group Screen...
Page 21
Change Group Gasket Remove Old Group Gasket & inner O-ring Clean group Soak Removed parts in Cleaner...
Page 22
Change Group Gasket Appy a thin coat of Silicone grease to Gasket & O-rings Do Not place Install Group O-ring on O-ring into gasket group first ! Holder!
Page 23
Change Group Gasket Assemble parts as shown Easy-Lock spring Do Not install group gasket at this time! Gently lift & Hold into place while installing screws Take care that the Group O-ring does not shift!
Page 24
Change Group Gasket Install New Group Install New Group Gently push Gasket in Gasket O-ring Gasket place Do Not push all the way in yet!
Page 25
Change Group Gasket Use a Porta-filter to seat the Group Gasket Install Locking Collar Place Porta-filter in Tighten screws to seat Insert screws only 1-2 Collar gasket evenly turns by hand...
Page 26
Change Group Gasket Do Not over tighten Diffuser Disk notch side screw down Fingertip tight only!
Page 40
Vacuum Break Valve Allows air into the boiler to prevent a vacuum from forming when the machine cools off --------Vacuum-------- Protects the seals and reduces the possibility of contaminants (milk etc.) entering boiler...
Start Heating ON Heating Element 3 Elements 1 & 2 Boiler should start Steam Pressure Check for power to all 3 getting warm elements with an ammeter starts to climb...
Page 48
Low Volume/Slow water flow from group Water Flow Test (Water Debit) 200ml Normal flow is 200ml in 20 seconds...
Page 49
Low Volume/Slow water flow from group #1 Service Normal flow is 10ml/second: Problem! 1. 9 bar brew pressure 2. 0.7m metering jet 3. Brew valve Probable Causes: 1. Clogged brew Valve Cleaning 2. Restricted 0.7m metering jet Water Scale 125ml 3.
Page 50
Low Volume/Slow water flow from group Ensure pump is running and set to 9 bars Brew Valve 0.7mm Metering Jet Flowmeter Coffee Residue Scale Water Debris/ Plumbers Tape...
Page 52
Fault Codes – Steam/Hot water Box Codes do not re-set until Hot Water Flowmeter switched OFF/ON Hot Water dosing set to ON in programming (even if problem is resolved) Set to OFF if no hot water flowmeter Normal Operation SteamAir Switched OFF Flowmeter Programming section: StA = OFF SteamAir button works by time...
Page 53
Fault Codes - Group Boxes Codes do not re-set until switched OFF/ON (even if problem is resolved) Flowmeter Filling Heating Flowmeter Dosamat Filling Flowmeter Dosamat Transducer Flowmeter SteamAir Transducer...
Page 54
Flowmeter Codes Group Harness for Groups G1, G2, or G3 Flowmeter Disconnected plug into CN8, CN9, or CN10 Flowmeter Short Circuit Usually Corrosion on plug or water leak Electric? or Water Flow? Stuck Impeller or corroded magnets No signal Replace impeller & clean flowmeter body Flowmeter works See Water Flow Test Section Dose timeout...
Page 55
Filling Codes Normal Filling Flashes once on startup to verify boiler is full Flashes after 3 minutes without filling (boiler cold) Boiler heating disabled Steady after 105 seconds without filling (boiler hot) Steam/Hot water box disabled to prevent draining boiler...
Page 56
Boiler Pressure Sensor Codes Steam Pressure Sensor Disconnected (Plug CN16) Steam Pressure Sensor Short Circuit Wiring Short Circuit CN16 Red, Brown, & Black wires from probe...
Page 57
Boiler Heating Code No Heating Sensor wires monitor the High Limit Switch Tripped High Limit Voltage across closed High Limit = 0 volts Voltage across tripped High Limit = 220 volts Sensor wires from High limit connect to CN2 High Limit re-set High Limit can only be re-set 3-4 times! Replace if frequently tripping under normal conditions...
Page 58
Boiler Heating Code No Heating Causes of Tripped High Limit: Tripped High Limit Overuse of Hot water Wand: Slow boiler re-filling: It is possible to take hot water out Clogged water filters of the boiler faster than it can refill Reduced water flow to the machine Be sure screw on filling valve is open 3 turns...
Other Codes Dosamat Sensor Disconnected Turn OFF Dosamat ( ) in programming if not installed Dosamat Sensor Short Circuit...
Page 60
Keypad Buttons Don’t Respond (Usually When Entering Programming) Clean keyboard glass Switch the machine Cover the keys fully Make sure the with window cleaner OFF and ON. This re- with your fingertips Protective film is calibrates the peeled from the capacitive buttons.
Page 61
Not Heating Screen Dashes Turn Power Switch LED lighted on SSRs cycling to heating position “2” to close heating 12-volt sent signal to Element circuit Solid Stare Relays in Switch position 1 & 2...
Page 62
Not Heating (All other functions work normally) Screen in ready mode Steady lines No 12-volt signal to Pressure control may be set to OFF Solid Stare Relays LED not lighted on SSRs Enable by switching to ON and adjusting pressure (See Manual)