Electrical Connections
Mid Range LightSpot should be connected in accordance with the diagram below.
Mid Range LightSpot is designed to control a switched load of up to 10 Amps.
When switching via the relay output, multiple MR1500Ps' relay outputs may be connected in parallel provided
the controlled load does not exceed 10 Amps.
Volt-Free Operation
Live In
Live In
Neutral
Earth
VOLT-
FREE
OUTPUT
No Connection
No Connection
Live-Out Operation
Live In
Live In
Neutral
Earth
VOLT-
FREE
OUTPUT
No Connection
No Connection
Note: A means of disconnection must be incorporated into the fixed wiring in accordance with the current
wiring regulations.
or
SWITCHED LOAD
10 Amps Maximum
3
Always check product label before wiring
Live
Mains
Neutral
Supply
Earth
Volt-Free Contacts
Live
Mains
Neutral
Supply
Earth