Page 1
Introduction Safety notices System overview SIMATIC RTLS Planning an RTLS system Anchors Gateways System Manual Transponder Accessories System integration System diagnostics 04/2019 C79000-G8976-C577-01...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Introduction..............................9 Safety notices .............................11 System overview ............................13 System overview ........................13 Planning an RTLS system ..........................17 Basics of application planning....................17 Field data of anchors, gateways and transponders ...............17 Installation guidelines......................17 Chemical resistance of anchors, gateways and transponders..........17 Directives on electromagnetic compatibility ................17 Anchors ..............................19 SIMATIC RTLS4030A ......................19 5.1.1...
Page 4
Table of contents 5.2.3 Technical specifications ......................40 5.2.4 Approvals ..........................41 5.2.4.1 UL............................44 SIMATIC RTLS4420A ......................45 5.3.1 Device description........................45 5.3.1.1 Characteristics ........................45 5.3.1.2 Order data RTLS4420A ......................45 5.3.1.3 Pin assignment........................46 5.3.1.4 LED status indicator .......................47 5.3.1.5 Dimension drawing.........................48 5.3.1.6 Troubleshooting ........................49 5.3.2 Installation &...
Page 5
Table of contents SIMATIC RTLS4330G......................84 6.2.1 Device description........................84 6.2.1.1 Characteristics ........................84 6.2.1.2 Order data RTLS4330G ......................84 6.2.1.3 Pin assignment........................85 6.2.1.4 LED status indicator .......................87 6.2.1.5 Dimension drawing.........................88 6.2.1.6 Troubleshooting ........................88 6.2.2 Installation & Operation......................89 6.2.2.1 Notes on installation.......................89 6.2.2.2 Installation options .........................90 6.2.2.3 Ethernet..........................92 6.2.2.4...
Page 6
Table of contents 7.1.1.1 Characteristics ........................125 7.1.1.2 Order data RTLS4030T......................125 7.1.1.3 LED status indicator ......................126 7.1.1.4 Dimension drawing.......................126 7.1.2 Installation & Operation......................126 7.1.2.1 Notes on installation......................126 7.1.2.2 Cleaning and maintenance ....................127 7.1.3 Technical specifications .......................128 7.1.4 Approvals ..........................129 7.1.4.1 UL............................132 SIMATIC RTLS4060T ......................133 7.2.1 Device description........................133...
Page 7
Installation & Operation......................169 7.6.2.1 Cleaning and maintenance ....................169 7.6.3 Technical specifications .......................170 7.6.4 Approvals ..........................171 7.6.4.1 UL............................174 SIMATIC RTLS PCB OEM AX .....................175 7.7.1 Device description........................175 7.7.1.1 Order data RTLS PCB OEM AX ..................175 7.7.1.2 Pin assignment........................175 7.7.1.3 LED status indicator ......................176 7.7.1.4...
Page 8
Table of contents Accessories ..............................197 System integration............................199 System diagnostics...........................201 Index.................................203 System Manual, 04/2019, C79000-G8976-C577-01...
Additional information (https://support.industry.siemens.com/cs/us/en/ps/25277) Trademarks SIMATIC RTLS ® is a registered trademark of the Siemens AG. Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support offers support at the following Internet address: (https:// support.industry.siemens.com/cs/us/en/)
Page 10
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
● For communication via non-secure networks use additional devices with VPN functionality to encrypt and authenticate the communication. ● Terminate the management connections properly (SIMATIC RTLS Locating Manager and its clients). ● Keep the firmware up to date. Check regularly for security updates for the device. You can find information on this at the Industrial Security (https://www.industry.siemens.com/topics/...
Page 12
Safety notices ● Use passwords with a high password strength. ● Make sure that all passwords are protected and inaccessible to unauthorized persons. ● Do not use the same password for different users and systems. Physical access Note the following security recommendations for physical access to the devices: ●...
This makes SIMATIC RTLS a crucial component of the digital infrastructure in the plant of the future. SIMATIC RTLS is used to implement localization tasks that require a high level of accuracy in large indoor or outdoor spaces.
Page 14
The quality of the data collected in production control and logistics increases significantly through the use of SIMATIC RTLS. In addition to identification of objects and vehicles, position data is available in real time. The localization platform covers entire buildings, halls and factory sites almost completely and ensures a degree of transparency that could not be achieved with established technology so far.
Page 15
3.1 System overview Easy integration into your automation level SIMATIC RTLS can be easily integrated into the IT landscape by means of the SIMATIC Locating Manager software. This ensures you will have an integrated software architecture and significant savings during engineering, commissioning and maintenance. A wide range of software functions (e.g.
Page 16
System overview 3.1 System overview System Manual, 04/2019, C79000-G8976-C577-01...
Planning an RTLS system Basics of application planning Field data of anchors, gateways and transponders Installation guidelines Chemical resistance of anchors, gateways and transponders Directives on electromagnetic compatibility System Manual, 04/2019, C79000-G8976-C577-01...
Page 18
Planning an RTLS system 4.5 Directives on electromagnetic compatibility System Manual, 04/2019, C79000-G8976-C577-01...
Anchors SIMATIC RTLS4030A 5.1.1 Device description 5.1.1.1 Characteristics SIMATIC RTLS4030A Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital output General The device is the home location for localiza‐ tion in the RTLS localization system. It collects the localization data and sends it to the localization server.
Anchors 5.1 SIMATIC RTLS4030A Table 5-2 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway 6GT2790-0BE30 Connecting cable for connection to wide-range power supply unit for anchor / gateway...
Anchors 5.1 SIMATIC RTLS4030A Meaning Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA 5.1.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
Anchors 5.1 SIMATIC RTLS4030A Meaning RADIO LED Flashes yellow when the radio signal of the device to the RTLS localization system is active SERVER LED Lights up blue when the device is connected to the local network 5.1.1.5 Dimension drawing Figure 5-1 Dimension drawing SIMATIC RTLS4030A - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
Anchors 5.1 SIMATIC RTLS4030A When the supply voltage is connected to the power plug, all LEDs flash briefly for a moment. The POWER LED lights up as soon as voltage is present. Make sure that a cable fuse is installed in front of the device. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications".
Page 25
Anchors 5.1 SIMATIC RTLS4030A Figure 5-2 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
PX0412/03P 5.1.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 29
Anchors 5.1 SIMATIC RTLS4030A Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems...
Page 30
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4030A (MLFB 6GT2701-5DA03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 31
Anchors 5.1 SIMATIC RTLS4030A (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement. 5.1.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ.
Anchors 5.2 SIMATIC RTLS4330A SIMATIC RTLS4330A 5.2.1 Device description 5.2.1.1 Characteristics SIMATIC RTLS4330A Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital output General The device is the home location for localiza‐ tion in the RTLS localization system. It collects the localization data and sends it to the localization server.
Anchors 5.2 SIMATIC RTLS4330A Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA 5.2.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
Dimension drawing SIMATIC RTLS4330A - All dimensions specified in millimeters 5.2.1.6 Troubleshooting If a fault occurs, inspect the device for the following errors and take appropriate measures. If there are other undefined errors, please contact Siemens Support (https:// support.industry.siemens.com/cs/start?lc=en-US). Error detection...
Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
Anchors 5.2 SIMATIC RTLS4330A Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Page 38
Anchors 5.2 SIMATIC RTLS4330A Figure 5-4 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. System Manual, 04/2019, C79000-G8976-C577-01...
Anchors 5.2 SIMATIC RTLS4330A Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids. 5.2.3 Technical specifications Table 5-6 Technical specifications of the anchor RTLS4330A 6GT2701-5EA03 Product name SIMATIC RTLS4330A PULSE radio frequencies Wireless method IEEE 802.15.4-2001 UWB Transmission speed 6.8 Mbps Operating frequency rated value...
Supply voltage 5.2.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 42
Anchors 5.2 SIMATIC RTLS4330A Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems...
Page 43
Anchors 5.2 SIMATIC RTLS4330A FCC information Siemens SIMATIC RTLS4330A (MLFB 6GT2701-5EA03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 44
Anchors 5.2 SIMATIC RTLS4330A 5.2.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ. LOC. The products meet the requirements of the following standards: Document Title UL 60079-0 Hazardous areas CSA C22.2 NO. 60079-0 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas...
Anchors 5.3 SIMATIC RTLS4420A SIMATIC RTLS4420A 5.3.1 Device description 5.3.1.1 Characteristics SIMATIC RTLS4420A Characteristics ① Design Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage and digital out‐ puts General The device is the home location for localization in the RTLS localization system.
Anchors 5.3 SIMATIC RTLS4420A Table 5-8 Accessories order data (not included in scope of delivery) Article number Antenna with N-M connector 4.5 dBi 6GT2706-0BA00 IWLAN antenna ANT795-6MN 6GK5795-6MN10-0AA6 Mounting set for ANT795-6MN 6GK5795-6MN01-0AA6 including mounting aid, angle adapter, N-Connect, fixing screws, Compact instructions Flexible connecting cable (e.g.
Anchors 5.3 SIMATIC RTLS4420A Output voltage: 0 (switched off) or input voltage (switched on) Maximum output current: 100 mA P2 - Antenna - RP-SMA connection Description Antenna Shielding GND, shielding 5.3.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
Anchors 5.3 SIMATIC RTLS4420A RUN LED (D2) Meaning Is off when the device is inactive Flashes regularly in green when an error is indicated Is on when the device is in operation. 5.3.1.5 Dimension drawing Figure 5-5 Dimension drawing SIMATIC RTLS4420A - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
The green LED (RUN) flashes during Error in the device Reset by switching the device off and on operation. again; if the error occurs again, contact SIEMENS Service. 5.3.2 Installation & Operation 5.3.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
Anchors 5.3 SIMATIC RTLS4420A Supply voltage When the supply voltage is connected at the "Power" input, all LEDs flash briefly for a moment. The POWER LED lights up permanently in green as soon as voltage is present. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications".
To restore the factory settings 5.3.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 52
Anchors 5.3 SIMATIC RTLS4420A RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Page 53
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4420A (MLFB 6GT2701-2CA02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 54
Anchors 5.3 SIMATIC RTLS4420A (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
Anchors 5.4 SIMATIC RTLS4430A The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] SIMATIC RTLS4430A 5.4.1 Device description 5.4.1.1 Characteristics SIMATIC RTLS4430A Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital outputs General The device is the home location for localiza‐...
Anchors 5.4 SIMATIC RTLS4430A Table 5-11 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway 6GT2790-0BE30 Connecting cable for connection to wide-range power supply unit for anchor / gateway...
Anchors 5.4 SIMATIC RTLS4430A Meaning Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA 5.4.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
Anchors 5.4 SIMATIC RTLS4430A Meaning RADIO LED Flashes yellow when the radio signal of the device to the RTLS localization system is active SERVER LED Lights up blue when the device is connected to the local network 5.4.1.5 Dimension drawing Figure 5-6 Dimension drawing SIMATIC RTLS4430A - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
Anchors 5.4 SIMATIC RTLS4430A Supply voltage When the supply voltage is connected at the "Power" input, all LEDs light briefly for a moment. The POWER LED lights up permanently in green as soon as voltage is present. Make sure that a cable fuse is installed upstream of the device. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications".
Page 61
Anchors 5.4 SIMATIC RTLS4430A Figure 5-7 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
Titanium gray Power plug 3-pin plug-in connector with screw-type terminal Bulgin Buc‐ caneer® PX0412/03P 5.4.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. System Manual, 04/2019, C79000-G8976-C577-01...
Page 64
Anchors 5.4 SIMATIC RTLS4430A Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
Page 65
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4430A (MLFB 6GT2701-5CA02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 66
Anchors 5.4 SIMATIC RTLS4430A Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 67
Anchors 5.4 SIMATIC RTLS4430A UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X...
Page 68
Anchors 5.4 SIMATIC RTLS4430A System Manual, 04/2019, C79000-G8976-C577-01...
Gateways SIMATIC RTLS4030G 6.1.1 Device description 6.1.1.1 Characteristics SIMATIC RTLS4030G Characteristics ① Design Status indicators (LEDs) ② Connector for power supply over mains connection ③ Ethernet port; Alternative power supply using Power over Ethernet (PoE) General The device is the home location for localiza‐ tion in the RTLS localization system.
Gateways 6.1 SIMATIC RTLS4030G Table 6-2 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Bayonet connector (Amphenol RCP-00BMMS-TLM7001) made of plastic 6GT2790-0CB00 for RJ45 connector for cable mounting (IP65) at gateway Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway...
Page 71
Gateways 6.1 SIMATIC RTLS4030G Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA Figure 6-1 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 System Manual, 04/2019, C79000-G8976-C577-01...
Gateways 6.1 SIMATIC RTLS4030G 6.1.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs. The states can be off , on and flashing . Meaning POWER LED Lights up green when power is supplied to the device through the mains cable POWER LED Flashes red once per second when there is an undervoltage at the device RADIO LED...
Gateways 6.1 SIMATIC RTLS4030G 6.1.1.5 Dimension drawing Figure 6-2 Dimension drawing SIMATIC RTLS4030G - All dimensions specified in millimeters 6.1.1.6 Troubleshooting Error detection Cause of the error Troubleshooting Device does not respond, all LEDs are The device is not connected or the pow‐ Check the supply voltage of the device.
Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
Gateways 6.1 SIMATIC RTLS4030G Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Page 76
Gateways 6.1 SIMATIC RTLS4030G Figure 6-3 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
Gateways 6.1 SIMATIC RTLS4030G Installation with support - Corner installation Follow the steps below to mount the device to a corner: 1. Use the corner support as template and draw the bore holes on the corner. 2. Drill the holes with a suitable device. 3.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
Amphenol LTW RCP-00AMMA-TLM7001 6.1.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 80
Gateways 6.1 SIMATIC RTLS4030G RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Page 81
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4030G (MLFB 6GT2701-5DB03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 82
Gateways 6.1 SIMATIC RTLS4030G Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 83
Gateways 6.1 SIMATIC RTLS4030G UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X...
Gateways 6.2 SIMATIC RTLS4330G SIMATIC RTLS4330G 6.2.1 Device description 6.2.1.1 Characteristics SIMATIC RTLS4330G Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital output ③ Ethernet port; Alternative power supply using Power over Ethernet (PoE) General The device is the home location for localiza‐ tion in the RTLS localization system.
Gateways 6.2 SIMATIC RTLS4330G Article number Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway 6GT2790-0BE30 6.2.1.3 Pin assignment Ethernet socket RJ45 The device may only be connected to the Ethernet via the plug-in connectors shown below. When connecting the Ethernet cable, ensure that the twist-lock connectors are correctly secured.
Page 86
Gateways 6.2 SIMATIC RTLS4330G Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA Connection socket Amphenol LTW RCP-5SPFFH-TCU7001 Figure 6-4 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 System Manual, 04/2019, C79000-G8976-C577-01...
Page 87
Gateways 6.2 SIMATIC RTLS4330G 6.2.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs. The states can be off , on and flashing . Display Meaning POWER LED Lights up green when power is supplied to the device through the mains cable POWER LED Flashes red once per second when there is an undervoltage at the device RADIO LED...
Dimension drawing SIMATIC RTLS4330G - All dimensions specified in millimeters 6.2.1.6 Troubleshooting If a fault occurs, inspect the device for the following errors and take appropriate measures. If there are other undefined errors, please contact Siemens Support (https:// support.industry.siemens.com/cs/start?lc=en-US). Error detection...
Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
Page 90
Gateways 6.2 SIMATIC RTLS4330G Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Page 91
Gateways 6.2 SIMATIC RTLS4330G Figure 6-6 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
Amphenol LTW PCP-00AMMA-TLM7001 6.2.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 95
Gateways 6.2 SIMATIC RTLS4330G The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the following areas of application. Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ●...
Page 96
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4330G (MLFB 6GT2701-5EB03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 97
Gateways 6.2 SIMATIC RTLS4330G (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement. 6.2.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ.
Gateways 6.3 SIMATIC RTLS4420G SIMATIC RTLS4420G 6.3.1 Device description 6.3.1.1 Characteristics SIMATIC RTLS4420G Characteristics ① Design Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage and digital outputs General The device is the home location for localiza‐ tion in the RTLS localization system.
Gateways 6.3 SIMATIC RTLS4420G Table 6-8 Accessories order data (not included in scope of delivery) Article number Antenna with N-M connector 4.5 dBi 6GT2706-0BA00 IWLAN antenna ANT795-6MN 6GK5795-6MN10-0AA6 Mounting kit for ANT795-6MN 6GK5795-6MN01-0AA6 including mounting aid, angle adapter, N-Connect Fixing screws, Compact instructions Flexible connecting cable (e.g.
Page 100
Gateways 6.3 SIMATIC RTLS4420G Description Supply voltage Ethernet shield Digital output - Connector 6 A high-side switch switches the power supply to the digital output (pin 6). Output voltage: 0 (switched off) or input voltage (switched on) Maximum output current: 100 mA P2 - Antenna - RP-SMA plug-in connector Description Antenna...
Page 101
Gateways 6.3 SIMATIC RTLS4420G Description Differential Ethernet receive data - 4, 5, 7, 8 Not connected Shield Grounding Description No connection Yellow 10 MBit Green 100 MBit Description No activity Yellow Half duplex activity Green Full duplex activity 6.3.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs.
The green LED (RUN) flashes during Error in the device Reset by switching the device off and on operation. again; if the error occurs again, contact SIEMENS Service. 6.3.2 Installation & Operation 6.3.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
Gateways 6.3 SIMATIC RTLS4420G Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Ethernet RJ45 Ethernet (10/100 MBit) Antenna connector RP SMA screw connector 6.3.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) System Manual, 04/2019, C79000-G8976-C577-01...
Page 106
Gateways 6.3 SIMATIC RTLS4420G The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 ●...
Page 107
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4420G (MLFB 6GT2701-2CB02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 108
Gateways 6.3 SIMATIC RTLS4420G can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Gateways 6.4 SIMATIC RTLS4430G The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X -40 °C <...
Gateways 6.4 SIMATIC RTLS4430G 6.4.1.2 Order data RTLS4430G Table 6-10 Order data RTLS4430G Article number SIMATIC RTLS4430G 6GT2701-5CB02 SIMATIC RTLS4430G specially based for CD 6GT2701-5CB02-0AX0 Table 6-11 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Bayonet connector (Amphenol RCP-00BMMS-TLM7001) made of plastic...
Page 111
Gateways 6.4 SIMATIC RTLS4430G Plug-in connector for power, digital output 3-pin plug-in connector Buccaneer® PX0412/03P Connectors: SA3350/1 Sealing cover: PX0480 System Manual, 04/2019, C79000-G8976-C577-01...
Page 112
Gateways 6.4 SIMATIC RTLS4430G Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA Connector Amphenol LTW RCP-5SPFFH-TCU7001 Figure 6-8 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 6.4.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs.
Gateways 6.4 SIMATIC RTLS4430G Meaning LAN/SERVER LED Flashes blue once per second when the device is connected to the network but there is no connection to the RTLS localization server LAN/SERVER LED Is off when the device is not connected to the network 6.4.1.5 Dimension drawing Figure 6-9...
Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
Page 115
Gateways 6.4 SIMATIC RTLS4430G The device can be supplied with power via the Ethernet cable. In this case, the power plug should be tightly sealed to prevent moisture from penetrating. Do not supply the device with power via the power input and PoE at the same time. The device is a class 0 device according to PoE.
Page 116
Gateways 6.4 SIMATIC RTLS4430G Figure 6-10 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
Page 117
Gateways 6.4 SIMATIC RTLS4430G Installation with support - Corner installation Follow the steps below to mount the device to a corner: 1. Use the corner support as template and draw the bore holes on the corner. 2. Drill the holes with a suitable device. 3.
Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
Amphenol LTW RCP-00AMMA-TLM7001 6.4.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 120
Gateways 6.4 SIMATIC RTLS4430G Applied standard: ● EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to restriction of hazardous substances The products described in this document meet the requirements of the applied standards: Article 3 (1) a) Protection of health and safety ●...
Page 121
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4430G (MLFB 6GT2701-5CB02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 122
Gateways 6.4 SIMATIC RTLS4430G (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
Page 123
Gateways 6.4 SIMATIC RTLS4430G The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] System Manual, 04/2019, C79000-G8976-C577-01...
Page 124
Gateways 6.4 SIMATIC RTLS4430G System Manual, 04/2019, C79000-G8976-C577-01...
Transponder SIMATIC RTLS4030T 7.1.1 Device description 7.1.1.1 Characteristics SIMATIC RTLS4030T Characteristics Design General The transponder is the mobile device for lo‐ calization in the RTLS localization system. It sends position data to anchors and gateways which transmit the data to the localization server.
Transponder 7.1 SIMATIC RTLS4030T 7.1.1.3 LED status indicator The operating states of the transponder are indicated by the LEDs. The states can be off , and flashing . LED (green) Meaning Flashes green briefly when the device is ready for operation. Flashes green permanently when the device is moved.
The device may only be repaired by an authorized maintenance company or opened for other types of work. Improper opening or repairing of the device may result in risks for the user. Opening the device without permission renders the warranty of the Siemens AG null and void. System Manual, 04/2019, C79000-G8976-C577-01...
Transponder 7.1 SIMATIC RTLS4030T Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products. 7.1.3 Technical specifications Table 7-2 Technical specifications of the transponder RTLS4030T 6GT2700-3DA03 Product name SIMATIC RTLS4030T PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2011 UWB Transmission speed 6.8 Mbps...
Anthracite 7.1.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 130
Transponder 7.1 SIMATIC RTLS4030T Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems...
Page 131
Transponder 7.1 SIMATIC RTLS4030T FCC information Siemens SIMATIC RTLS4030T (MLFB 6GT2700-3DA03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 132
Transponder 7.1 SIMATIC RTLS4030T 7.1.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ. LOC. The products meet the requirements of the following standards: Document Title UL 60079-0 Hazardous areas CSA C22.2 NO. 60079-0 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas...
Transponder 7.2 SIMATIC RTLS4060T SIMATIC RTLS4060T 7.2.1 Device description 7.2.1.1 Characteristics SIMATIC RTLS4060T Characteristics Design General The transponder is the mobile device for lo‐ calization in the RTLS localization system. It sends position data to anchors and gateways which transmit the data to the localization server.
Page 134
Transponder 7.2 SIMATIC RTLS4060T Description Color of the cable core Digital input 2 Orange Digital input 1 Yellow CAN L Green CAN H Blue Not used Violet Digital output Both digital device outputs can switch resistive, capacitive and inductive loads. The current is automatically limited to these functions.
Transponder 7.2 SIMATIC RTLS4060T 7.2.1.4 Dimension drawing Figure 7-2 Dimension drawing SIMATIC RTLS4060T - All dimensions specified in millimeters 7.2.2 Installation & Operation 7.2.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
Transponder 7.2 SIMATIC RTLS4060T Connection of the cables Make sure that the wiring is correct before you start up the device. Supply voltage CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
Light grey (RAL 7035) Plug-in connector 8-pin plug-in connector – cable socket PX0410/08S/6065 7.2.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) System Manual, 04/2019, C79000-G8976-C577-01...
Page 138
Transponder 7.2 SIMATIC RTLS4060T The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 ●...
Page 139
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4060T (MLFB 6GT2700-6DE03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 140
Transponder 7.2 SIMATIC RTLS4060T can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Transponder 7.3 SIMATIC RTLS4083T The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X -15 °C <...
Transponder 7.3 SIMATIC RTLS4083T 7.3.1.2 Order data RTLS4083T Table 7-6 Order data RTLS4083T Article number SIMATIC RTLS4083T 6GT2700-5DC03 Table 7-7 Accessories order data (not included in scope of delivery) Article number Charging station for 10 transponders 6GT2790-0DD00 with power plug for region: D / F / NL / ESP / B / A / S / FIN Charging station for 10 transponders 6GT2790-0DD01 with power plug for region: USA...
Transponder 7.3 SIMATIC RTLS4083T 7.3.1.4 Dimension drawing Figure 7-3 Dimension drawing SIMATIC RTLS4083T - All dimensions specified in millimeters 7.3.2 Installation & Operation 7.3.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
Improper opening or repairing of the device may result in risks for the user. Opening the device without permission renders the warranty of the Siemens AG null and void. Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products.
Titanium gray 7.3.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 146
Transponder 7.3 SIMATIC RTLS4083T RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Page 147
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4083T (MLFB 6GT2700-5DC03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 148
Transponder 7.3 SIMATIC RTLS4083T IC information This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Transponder 7.4 SIMATIC RTLS4084T The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X -20 °C <...
Transponder 7.4 SIMATIC RTLS4084T 7.4.1.2 Order data RTLS4084T Table 7-9 Order data RTLS4084T Article number SIMATIC RTLS4084T 6GT2700-7DC03 including 4 x SAFT 3 V lithium batteries (already installed) 7.4.1.3 LED status indicator, display & function key The operating states of the transponder are indicated by the LED. The LED can be green and red and have the states off , on , flashes .
Transponder 7.4 SIMATIC RTLS4084T Figure 7-4 Dimension drawing SIMATIC RTLS4084T - All dimensions specified in millimeters 7.4.2 Installation & Operation 7.4.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation. The devices can only be used in conjunction with the RTLS localization system. Setup, installation and use of the tools and clients of the RTLS localization system are described in the corresponding manuals.
Improper opening or repairing of the device may result in risks for the user. Opening the device without permission renders the warranty of the Siemens AG null and void. Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products.
Fastening clip, double-sided adhesive tape Enclosure Plastic housing Color Titanium gray 7.4.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) System Manual, 04/2019, C79000-G8976-C577-01...
Page 154
Transponder 7.4 SIMATIC RTLS4084T The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 ●...
Page 155
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4084T (MLFB 6GT2700-7DC03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 156
Transponder 7.4 SIMATIC RTLS4084T Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Page 157
Transponder 7.4 SIMATIC RTLS4084T UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X...
Transponder 7.5 SIMATIC RTLS4460T SIMATIC RTLS4460T 7.5.1 Device description 7.5.1.1 Characteristics SIMATIC RTLS4460T Characteristics ① Design Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage and digital inputs General The transponder is the mobile device for lo‐ calization in the RTLS localization system.
Page 159
Transponder 7.5 SIMATIC RTLS4460T Article number Antenna cable, 3 m 6GT2791-6AH30 Flexible connecting cable (e.g. for connecting an antenna to an access point) 6XV1875-5CH10 6XV1875-5CH20 6XV1875-5CH50 7.5.1.3 Pin assignment P1 - Plug-in connector for power, digital output 16-pin plug-in connector WR-MPC4 0.33 mm open 1.31 mm Description...
Page 160
Transponder 7.5 SIMATIC RTLS4460T Digital output Both digital device outputs can switch resistive, capacitive and inductive loads. The current is automatically limited to these functions. The following must be observed for inductive loads (e.g. relays): Inductivities up to 32 H can be switched off without freewheeling diode D .
Page 161
Transponder 7.5 SIMATIC RTLS4460T 7.5.1.4 LED status indicator Possible LED states The operating states of the transponder are indicated by the LEDs. The states can be off , and flashing . RADIO LED (D1) Meaning Is off when the device is inactive Flashes once every 0.5 seconds when a test is conducted during device start.
Page 162
Transponder 7.5 SIMATIC RTLS4460T 7.5.1.5 Dimension drawing Figure 7-5 Dimension drawing SIMATIC RTLS4460T - All dimensions specified in millimeters 7.5.2 Installation & Operation 7.5.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
Page 163
Transponder 7.5 SIMATIC RTLS4460T Connection of the cables Make sure that the wiring is correct before you start up the device. Connection of the antenna Connect the antenna to the RP SMA connection (P2). The device must not be operated without an antenna.
Page 164
Mini blade-type fuse, 2 A 7.5.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
Page 165
Transponder 7.5 SIMATIC RTLS4460T RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Page 166
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4460T (MLFB 6GT2700-6CE02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 167
Transponder 7.5 SIMATIC RTLS4460T (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
Page 168
Transponder 7.6 SIMATIC RTLS PCB OEM AC The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] SIMATIC RTLS PCB OEM AC 7.6.1 Device description 7.6.1.1 Order data RTLS PCB OEM AC Table 7-14 Order data RTLS PCB OEM AC...
Page 169
7.6.1.4 Dimension drawing The UWB antenna is arranged diagonally standing up on the top side of the PCB. Figure 7-6 Dimension drawing SIMATIC RTLS PCB OEM AC - All dimensions specified in millimeters 7.6.2 Installation & Operation 7.6.2.1 Cleaning and maintenance The device may only be opened by suitably trained and qualified personnel.
Page 170
Transponder 7.6 SIMATIC RTLS PCB OEM AC Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void.
Page 171
Transponder 7.6 SIMATIC RTLS PCB OEM AC 6GT2700-8DF00-0AX1 PCB dimensions (L x W x H) 25 x 25 x 18 mm Antenna dimensions (L x W x H) 20.6 x 12.7 x 1.6 mm Weight Approx. 6 g Degree of protection IP00 7.6.4...
Page 172
Transponder 7.6 SIMATIC RTLS PCB OEM AC The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the following areas of application. Article 3 (1) b) EMC ● ETSI EN 301 489-1...
Page 173
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM AC (MLFB 6GT2700-8DF00-0AX1); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 174
Transponder 7.6 SIMATIC RTLS PCB OEM AC Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le...
Page 175
Transponder 7.7 SIMATIC RTLS PCB OEM AX The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] SIMATIC RTLS PCB OEM AX 7.7.1 Device description 7.7.1.1 Order data RTLS PCB OEM AX Table 7-16 Order data RTLS PCB OEM AX...
Page 176
Transponder 7.7 SIMATIC RTLS PCB OEM AX Description / Function Grounding Grounding P800 socket Internal interface for production and manufacturing test, do not use. P201 socket TMA connector Type: JST BM08B-SRSS-G-TBT Description / Function Not used Power In +5 V...
Page 177
7.7 SIMATIC RTLS PCB OEM AX 7.7.1.4 Dimension drawing The two antennas are arranged standing up on the top side of the PCB. Figure 7-7 Dimension drawing SIMATIC RTLS PCB OEM AX - All dimensions specified in millimeters 7.7.2 Installation & Operation 7.7.3 Technical specifications...
Page 178
Transponder 7.7 SIMATIC RTLS PCB OEM AX 6GT2700-8DF00-0AX0 Operating frequency rated value 3100 MHz … 4800 MHz 6000 MHz ... 7000 MHz Transmit power 0.037 mW (-41.3 dBm/MHz) Range Max. 30 m Accuracy of the localization 0.2 m Antennas UWB antenna integrated PHASE radio frequencies (data transfer and optional locali‐...
Page 179
Transponder 7.7 SIMATIC RTLS PCB OEM AX The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
Page 180
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM AX (MLFB 6GT2700-8DF00-0AX0); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 181
Transponder 7.7 SIMATIC RTLS PCB OEM AX Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Page 182
Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC.
Page 183
Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP Description / Function Tx - Output on transponder, 2.5 V Supply voltage, 3.3 V ±100 mV P1 connector The individual pins are connected to the solder contacts (P4). Type: JST SM04B-SRSS-TB Description / Function Rx - Input on the transponder, 2.5 V (3.3 V)
Page 184
Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP Figure 7-8 All dimensions specified in millimeters. Antenna Figure 7-9 All dimensions specified in millimeters. System Manual, 04/2019, C79000-G8976-C577-01...
Page 186
Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
Page 187
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM CHIRP (MLFB 6GT2700-8CF02); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 188
Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Page 189
Transponder 7.9 SIMATIC RTLS PCB OEM PULSE UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC.
Page 190
Transponder 7.9 SIMATIC RTLS PCB OEM PULSE Description / Function Tx - Output on the transponder, 3.3 V Supply voltage 3.3 V P1 connector The individual pins are connected to the solder contacts (P4). Type: JST SM04B-SRSS-TB Description / Function Rx - Input on the transponder, 3.3 V...
Page 191
Transponder 7.9 SIMATIC RTLS PCB OEM PULSE Figure 7-10 All dimensions specified in millimeters. Antenna Figure 7-11 All dimensions specified in millimeters. System Manual, 04/2019, C79000-G8976-C577-01...
Page 193
Transponder 7.9 SIMATIC RTLS PCB OEM PULSE Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
Page 194
The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM PULSE (MLFB 6GT2700-8AF03); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
Page 195
Transponder 7.9 SIMATIC RTLS PCB OEM PULSE (2) this device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Page 196
Transponder 7.9 SIMATIC RTLS PCB OEM PULSE You will find the current versions of the standards in the currently valid UL HAZ. LOC. certificates. UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval.
Page 197
Accessories System Manual, 04/2019, C79000-G8976-C577-01...
Page 198
Accessories System Manual, 04/2019, C79000-G8976-C577-01...
Page 199
System integration System Manual, 04/2019, C79000-G8976-C577-01...
Page 200
System integration System Manual, 04/2019, C79000-G8976-C577-01...
Page 201
System diagnostics System Manual, 04/2019, C79000-G8976-C577-01...
Page 202
System diagnostics System Manual, 04/2019, C79000-G8976-C577-01...
Page 203
Index Support, 9 Training, 9 System Manual, 04/2019, C79000-G8976-C577-01...
Page 204
Index System Manual, 04/2019, C79000-G8976-C577-01...