LCD-Keypad for
SPC4000/5000/6000
User Manual
Building Technologies
Fire Safety & Security Products

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SPCK420

  • Page 1 SPCK420/421 LCD-Keypad for SPC4000/5000/6000 User Manual Building Technologies Fire Safety & Security Products...
  • Page 2 Data and design subject to change without notice. / Supply subject to availability. © 2008 Copyright by Siemens Building Technologies We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
  • Page 3: Table Of Contents

    Meaning of the written warning notices ............5 Meanings of the hazard symbols ..............5 Directives and Standards...............6 EU Directives ....................6 Introducing the SPCK420/421 (SPC Keypads)........7 Using the Keypad Interface..............9 Setting, Unsetting, and Restoring the System........11 Setting the System: FULLSET ..............11 Setting the System: PARTSET A............12 Setting the System: PARTSET B............12...
  • Page 4 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 5: Security

    Possible danger of death or severe bodily harm. CAUTION Danger of minor bodily injury or property damage IMPORTANT Danger of malfunctions Meanings of the hazard symbols WARNING Warning of a hazard area WARNING Warning of dangerous electrical voltage Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 6: Directives And Standards

    This product complies with the requirements of the European Directives 2004/108/EC“Directive of Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. The EU declaration of conformity is available to the responsible agencies at: Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe European Directive 2004/108/EC „Electromagnetic Compatibility”...
  • Page 7: Introducing The Spck420/421 (Spc Keypads)

    Introducing the SPCK420/421 (SPC Keypads) Introducing the SPCK420/421 (SPC Keypads) The SPC LCD Keypad is a wall-mounted programming interface unit that allows users to enter User Programming menus (password protected), and to perform operational procedures (set/unset) on the system. The Keypad unit includes an integral front tamper switch and has a 2 line x 16 character display.
  • Page 8 Introducing the SPCK420/421 (SPC Keypads) Programming Keys: 1 x multi-functional navigation key 2 x context sensitive programming keys (left and right) Portable ACE Receiver Area LED (Status Indicator see Tab. 2) Keypad: 12 x alphanumeric keys for numeric and text data entry...
  • Page 9: Using The Keypad Interface

    SELECT to select the option displayed on the top line – ENTER to enter the data displayed on the top line – SAVE to save a setting – Multi-Function Navigation Key (Navi-Key) Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 10 In alphanumeric mode, pressing this key over an upper case character changes the character to lower case. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 11: Setting, Unsetting, And Restoring The System

    When the system SYSTEM FULLSET has been fully set, the LCD displays FULLSET on the bottom line for approximately 10 seconds. If the alarm fails to set, see Section 5.4 Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 12: Setting The System: Partset A

    FULLSET or PARTSET A/B option is selected. The Keypad displays the zone number and description. To set the system, locate the zone and close or fix the fault. Repeat the FULLSET or PARTSET A/B operation. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 13: Force Setting The System

    ALARM ZONE 2 The source of the alarm condition is displayed FIRST ZONE on the Keypad and the Alert LED flashes. The Keypad continues to display the alert until the alert is restored. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 14: Restoring An Alarm Activation (Alert)

    An Alert condition only displays on the Keypad when the system is UNSET. If the system is SET when an alert condition occurs, the Keypad gives no indication of that alert condition until such time as the system is UNSET. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 15: Coded Restore

    The coded restore feature can only be operated from the Keypad. This feature is not accessible from the SPC5000/6000 web server browser. Using 868MHz Wireless Fob* *NOTE: Wireless features and devices will be available with a later market package. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 16: Using A Portable Ace

    Tab. 3 X10 Codes and Descriptions NOTE X10 uses uni-directional communication and should not be used for critical devices because system interference can prevent the device from responding to the command. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 17: User Menu Options

    BACK SELECT NOTE Only the Alarm, Exit/Entry, Fire Exit and Line Zone types can be inhibited on the SPC system. All other zone types are not displayed in the inhibit menus. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 18: Isolating A Zone Or Fault

    To enter a new time, press the required numeric keys. To move the cursor to the left and right, press the left and right arrow keys. Press ENTER (right soft key) to save the new time. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 19: Perform Tests

    To enable or disable the chime function: EXIT SELECT Scroll to the CHIME option and press SELECT (right soft key)..ENABLED... Toggle between enable or disable for the BACK SELECT chime function. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 20: Creating System Users

    During the process if the display times out, the old code remains valid. NOTE Where User Duress feature is enabled, consecutive user codes (i.e. 2906, 2907) are not permitted, as entering this code from the Keypad would activate a user duress event. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 21: Sms

    DISABLED and press SELECT (right soft key). NOTE SPC4000 provides only Engineer Access. Menu options on the SPC4000 display allowing and disallowing Engineer Access only. Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 22: Appendix

    RESTORE option in user programming is selected for that zone. To RESTORE an alert, see Section 5.7. Tab. 4 Standard User Settings Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 23: Appendix B: User Configuration And Test Options

    To enable or disable the chime attribute, see Section 6.6. SETUP Manager This feature allows users to set up the SMS messaging service if a modem is installed on the system. Tab. 5 User Configuration and Test Options Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 24: Appendix C: Zone Chart

    Appendix Appendix C: Zone Chart Zone # Description Siemens Building Technologies Fire Safety & Security Products 09.2008...
  • Page 26 Issued by Siemens Building Technologies © 2008 Copyright by Fire & Security Products GmbH & Co. oHG Siemens Building Technologies D-76181 Karlsruhe Data and design subject to change without notice. Supply subject to availability. www.buildingtechnologies.siemens.com/ Document no. A6V10209178 Edition 23.09.2008...