7PG2113/4/5/6 Solkor Settings
7PG2113/4/5/6
Feeder Protection
Document Release History
This document is issue 2010/08. The list of revisions up to and including this issue is:
2010/08
First Issue
Software Revision History
The copyright and other intellectual property rights in this document, and in any model or article produced from it
(and including any registered or unregistered design rights) are the property of Siemens Protection Devices
Limited. No part of this document shall be reproduced or modified or stored in another form, in any data retrieval
system, without the permission of Siemens Protection Devices Limited, nor shall any model or article be
reproduced from this document unless Siemens Protection Devices Limited consent.
While the information and guidance given in this document is believed to be correct, no liability shall be accepted
for any loss or damage caused by any error or omission, whether such error or omission is the result of
negligence or any other cause. Any and all such liability is disclaimed.
©2010 Siemens Protection Devices Limited

Advertisement

Table of Contents
loading

Summary of Contents for Siemens 7PG2113

  • Page 1 Limited. No part of this document shall be reproduced or modified or stored in another form, in any data retrieval system, without the permission of Siemens Protection Devices Limited, nor shall any model or article be reproduced from this document unless Siemens Protection Devices Limited consent.
  • Page 2: Table Of Contents

    Figure 1.1 -1 Fascia Links............................3 Figure 1.2 -1 Menu..............................4 Figure 1.2-2 Fascia Contrast symbol ........................4 Figure 1.2-3 Fascia of a 7PG2113/4/5/6 relay ......................5 Figure 2.1-1 USB connection to PC ........................17 Figure 2.1-2 RS485 connection to PC ........................18 Figure 2.1-3 PC Comm Port Selection........................
  • Page 3: Section 1: Introduction

    Fault Data Mode - allows the user to see type and data of any fault that the relay has detected. Control Mode - allows the user to control external plant under the relays control for example the CB ©2010 Siemens Protection Devices Limited Chapter 2 Page 3 of 21...
  • Page 4: Figure 1.2 -1 Menu

    To change the contrast on the LCD insert a flat bladed screwdriver into the screwhead below the contrast symbol, turning the screwhead left (anti-clockwase) lightens the contrast of the LCD and turning it right (clockwise) darkens the display. Figure 1.2-3 Fascia Contrast symbol ©2010 Siemens Protection Devices Limited Chapter 2 Page 4 of 21...
  • Page 5: Figure 1.2-3 Fascia Of A 7Pg2113/4/5/6 Relay

    7PG2113/4/5/6 Solkor Settings Figure 1.2-4 Fascia of a 7PG2113/4/5/6 relay ©2010 Siemens Protection Devices Limited Chapter 2 Page 5 of 21...
  • Page 6: Operation Guide

    LEDs will momentarily light up to indicate their correct operation. It also moves the cursor right ► when navigating through menus and settings. ©2010 Siemens Protection Devices Limited Chapter 2 Page 6 of 21...
  • Page 7: Setting Mode

    7PG2113/4/5/6 Solkor Settings Figure 1.3-2 Menu Structure Setting Mode The Settings Mode is reached by pressing the READ DOWN ▼ button from the relay identifier screen. ©2010 Siemens Protection Devices Limited Chapter 2 Page 7 of 21...
  • Page 8 Once editing is complete pressing the ENTER button stores the new setting into the non-volatile memory. The actual setting ranges and default values for each relay model and version of the numeric module can be found in the appendix to this manual. ©2010 Siemens Protection Devices Limited Chapter 2 Page 8 of 21...
  • Page 9: Instruments Mode

    This meter displays the Nominal current 0.00XIn---- 0.00XIn---- 0.00XIn---- Pri Earth Current This meter displays the Primary earth current. The value displayed will automatically adjust 0.00A between A and kA. 0.00A ©2010 Siemens Protection Devices Limited Chapter 2 Page 9 of 21...
  • Page 10 0.00xVn 0.00xVn Prim Ph-N Voltage This meter displays the Primary RMS Phase to Neutral Voltage 0.00kV 0.00kV 0.00kV Sec Ph-N Voltage This meter displays the Secondary Phase to Neutral ©2010 Siemens Protection Devices Limited Chapter 2 Page 10 of 21...
  • Page 11 Displays Power Factor PF B 0.00 PF C 0.00 PF (3P) 0.00 ENERGY METERS This is the sub-group that includes all the meters that are associated with Energy TEST/RESET allows ©2010 Siemens Protection Devices Limited Chapter 2 Page 11 of 21...
  • Page 12 Maintenance TEST/RESET →to view allows access to this sub-group CB Total Trips This meter shows the number of CB trips experienced by the CB Count Target ©2010 Siemens Protection Devices Limited Chapter 2 Page 12 of 21...
  • Page 13 This is the sub-group that includes all the meters that DEMAND METERS are associated with Demand. TEST/RESET allows →to view access to this sub-group I Phase A Demand 0.00A ©2010 Siemens Protection Devices Limited Chapter 2 Page 13 of 21...
  • Page 14 V Phase C Demand 0.00V 0.00V Mean 0.00V V Phase AB Demand 0.00V 0.00V Mean 0.00V V Phase BC Demand 0.00V 0.00V Mean 0.00V V Phase CA Demand 0.00V 0.00V ©2010 Siemens Protection Devices Limited Chapter 2 Page 14 of 21...
  • Page 15 COMMNICATIONS METERS Displays when the communication port is active →to view Com1 Com2 COM1 TRAFFIC COM1 Tx1 COM1 Rx Error COM1 Rx ©2010 Siemens Protection Devices Limited Chapter 2 Page 15 of 21...
  • Page 16: Fault Data Mode

    TEST/RESET► button. Each record contains data on the operated elements, analogue values and LED flag states at the time of the fault. The data is viewed by scrolling down using the ▼ button. ©2010 Siemens Protection Devices Limited Chapter 2 Page 16 of 21...
  • Page 17: Section 2: Setting & Configuring The Relay Using Reydisp Evolution

    Interface cable and converters are required depending which port is being used. 2.1.1 Front USB connection To connect your pc locally via the front USB port. Figure 2.1-1 USB connection to PC ©2010 Siemens Protection Devices Limited Chapter 2 Page 17 of 21...
  • Page 18: Rear Rs485 Connection

    RS485 port 75 110 150 300 600 1200 COM1-RS485 Baud 2400 4800 9600 19200 19200 Rate 38400 NONE, ODD, EVEN EVEN COM1-RS485 Parity OFF, IEC60870-5-103, IEC60870-5- MODBUS-RTU, COM2-USB Protocol ASCII,DNP3 ©2010 Siemens Protection Devices Limited Chapter 2 Page 18 of 21...
  • Page 19: Connecting To The Relay For Setting Via Reydisp

    The Reyrolle Language File Editor tool and its user manual are installed as part of the Reydisp Evolution software package. They can be found in your pc as sub menus of the Reydisp Evolution installation. ©2010 Siemens Protection Devices Limited Chapter 2 Page 19 of 21...
  • Page 20: Figure 2.1-4 Pc Language File Editor

    Care should be taken to ensure a unique file name is given including a version control reference. The user will be prompted to restart the relay to activate the language file. Please refer to the Language Editor Manual for further guidance. ©2010 Siemens Protection Devices Limited Chapter 2 Page 20 of 21...
  • Page 21: Figure 2.1-5 Language File Editor Setting Texts

    7PG2113/4/5/6 Solkor Settings Figure 2.1-5 Language File Editor Setting Texts ©2010 Siemens Protection Devices Limited Chapter 2 Page 21 of 21...

This manual is also suitable for:

7pg21147pg21157pg2116

Table of Contents