Technical Specifications
5.4 Copper Ethernet Port Specifications
5.4

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RSG2288.
Note
Connector
Speed
Duplex
Cable Type
Wiring Standard
Maximum Distance
Isolation
a
Auto-Negotiating
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.5

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered
with the RUGGEDCOM RSG2288.
38
Standard
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3x
IEEE 802.1D
IEEE 802.1Q
IEEE 802.1p
IEEE 1588 v2
Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens sales associate when
determining maximum segment distances.
All optical power numbers are listed as dBm averages.
F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
RJ45
1000 Mbps
a
FDX/HDX
b
> CAT-5
c
TIA/EIA T568A/B
d
100 m (328 ft)
e
1.5 kV
Description
1000BaseSX/LX
1000BaseTx
Flow Control
MAC Bridges
VLAN (Virtual LAN) Tagging
Class of Service
Precision Time Protocol
RUGGEDCOM RSG2288