1.9 United States Regulations Compliance

US Regulation
OSHA 29 CFR 1910.212
OSHA 29 CFR 1910.217
Safety light curtains may be used as primary protection for machines where the movement of the functional parts can be
interrupted at any moment in a dangerous phase.
Safety light curtains may be used as primary protection for machines on which the control circuit has been designed in
such a manner that a fault in one component does not result in any risk.
Cancellation of the safety light curtain stop signal must not cause the restart of the moving parts. The function to restart
can only be initiated by means of a control designed for this purpose.

1.10 United States Standards Compliance

Installation and use of the FF-SYA light curtain must comply with the following applicable American standards (non-exhaustive
list):
Standards
ANSI B11.1
ANSI B11.2
ANSI B11.19
ANSI/RIA R15.06 - 1999

1.11 Additional Protection

In some applications, it may be necessary to provide additional protection to maintain the protection level provided by the
safety light curtain. Hard guards or additional presence sensing devices such as safety mats or laser scanner, may be used to
ensure the operator is either forced to move through the sensing field to enter the danger zone, or forced to stand on the
sensing area inside the danger zone.
Hard guards should be installed permanently with the aid of a tool or welded (if possible). If hard guards need to be
automatically positioned, their positioning must be checked. It must not be possible for operators to neutralise the detectors
associated with these hard guards. Hard guards shall comply with the following applicable European Standards:
Standards
Title
EN 953
Safety of Machinery - General requirements for the design and construction of guards
EN 294
Safety of Machinery - Safety distances to prevent danger zones from being reached by the upper limbs
EN 811
Safety of Machinery - Safety distances to prevent danger zones from being reached by the lower limbs
EN 1088
Safety of Machinery - Interlocking devices with and without guard locking
EN 954-1
Safety of Machinery - Safety related parts of control system
Honeywell FF-SR Series safety control modules may be used as an interface between protective safety equipment and
machine control circuitry. The following safety control modules are particularly recommended:
FF-SRS: safety control module designed for emergency stop
FF-SRD Series: safety control module designed for door monitoring
FF-SR2: safety relay control module designed for two-hand controls
FF-SR0 Series: safety control module designed for standstill detection on inductive motors
FF-SRT Series: time delay module
FF-SRE Series: extension relay module
They offer redundancy, monitoring, and control reliability features that ensure the highest level of industrial safety.
Honeywell safety switches and sensors that may be used to check the position of guards include:
GSS safety limit switches
GK and GKM key operated safety switches
GKR/L solenoid key operated safety interlock switches
24/924CE miniature safety limit switch
Honeywell safety optoelectronic products that may be used with the FF-SYA Series safety light curtain include:
FF-SM safety mat
FF-SE laser scanner
FF-SPS4 single beam safety device
FF-SCAN modular safety light curtain
107031-33-EN FR26 GLO 1101 Printed in France
Title
General Requirements for (guarding of) All Machines
(Guarding of) Mechanical Power Presses
Title
Mechanical Power Presses
Hydraulic Power Presses
Safeguarding when Referenced by the Other B11 Machine Tool Safety Standards
Safety Requirements for Industrial Robots and Robot Systems
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ff-sya30 seriesFf-sya60 seriesFf-sya234

Table of Contents