hit counter script
Siemens SIMATIC NET RUGGEDCOM M2200 Installation Manual
Siemens SIMATIC NET RUGGEDCOM M2200 Installation Manual

Siemens SIMATIC NET RUGGEDCOM M2200 Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM M2200:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM M2200
Edition
03/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM M2200

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM M2200 Edition 03/2020 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM M2200 Communication Ports Technical Specifications Installation Manual Certification 03/2020 C79000-G8976-1044-16...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Failsafe Relay Specifications ................25 Supported Networking Standards ................ 25 Copper Ethernet Port Specifications ..............26 Fiber Optic Ethernet Port Specifications ............... 27 Operating Environment ..................27 Mechanical Specifications ..................27 Dimension Drawings ................... 28 Certification ......................... 31 Approvals ......................
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of pur- chase, conditional upon the return to factory for maintenance during the warranty term.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7 Telephone Toll-free: 1 888 264 0006 Tel: +1 905 856 5288...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 10: Introduction

    Introduction The RUGGEDCOM M2200 is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically de- manding utility substation, railway and industrial environments. The RUGGEDCOM M2200’s superior rugged hardware design coupled with the embedded Rugged Op- erating System (ROS) provides improved system reliability and advanced cyber secu- rity and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control applications.
  • Page 11: Description

    Introduction 1.2 Description Universal Power Supply Options • Fully integrated, dual-redundant (optional) power supplies • Universal high-voltage range: 88-300 VDC or 85-264 VAC • Popular low voltage ranges: 24 VDC (10-36 VDC), 48 VDC (36-72 VDC) • Screw or pluggable terminal blocks for reliable, maintenance-free connections •...
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Mode Color/State Description Speed Green (Solid) 100 Mbps Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode for the port status indicator LEDs (i.e. Status, Duplex or Speed). Mode Button The Mode button sets the display mode for the port status indicator LEDs (i.e.
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 14: 1.5.3 Supported Fiber Optic Cables

    Introduction 1.5.3 Supported Fiber Optic Cables Follow these recommendations for copper data cabling in high electrical noise envi- ronments: • Data cable lengths should be as short as possible, preferably 3 m (10 ft) in length. Copper data cables should not be used for inter-building communica- tions.
  • Page 15 Introduction 1.5.3 Supported Fiber Optic Cables RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM M2200 is designed for maximum mounting and display flexibili- ty.
  • Page 18: Mounting The Device To A Rack

    Installing the Device 2.3.1 Mounting the Device to a Rack 2.3.1 Mounting the Device to a Rack The RUGGEDCOM M2200 can be secured to a standard 48 cm (19 in) rack using sep- arately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 19: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel Make sure the rack mount adapters are installed on the correct side of the chas- sis. • To make the modules and ports accessible, install the rack mount adapters at the rear of the chassis •...
  • Page 20: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel Adapter Figure 2.2 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 21: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM M2200 supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM M2200 can be equipped with either a screw-type or pluggable ter- minal block, which provides power to both power supplies .
  • Page 22: Connecting Ac Or Dc Power

    Installing the Device 2.5.1 Connecting AC or DC Power • It is recommended to provide a separate circuit breaker for each power supply module. • Equipment must be installed according to applicable local wiring codes and stan- dards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: NOTICE...
  • Page 23 Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Figure 2.4...
  • Page 24: 2.5.2 Wiring Examples

    Installing the Device 2.5.2 Wiring Examples Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground terminal on the device. Make sure the lug is tight- ened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Lug...
  • Page 25 Installing the Device 2.5.2 Wiring Examples Figure 2.6 Single AC Power Supply Figure 2.7 Single DC Power Supply RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 26 Installing the Device 2.5.2 Wiring Examples Figure 2.8 Dual AC Power Supply Figure 2.9 Dual DC Power Supply RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 27 Installing the Device 2.5.2 Wiring Examples Figure 2.10 Dual AC/DC Power Supply RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM M2200 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM M2200.
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM M2200 console and Web interfaces via the device's IP address.
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM M2200 can be equipped with various types of communication ports to enhance its abilities and performance. With five available slots, the RUGGED- COM M2200 supports a variety of one- or two-port fiber or copper Ethernet module of various speeds with up to nine Gigabit Ethernet (1 Gbps) ports.
  • Page 31: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports   LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Port LED Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM M2200 supports several 10/100Base-TX and 10/100/1000Base- TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with Micro-D male connectors.
  • Page 32: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Name Description 10/100Base-TX 1000Base-TX Reserved (Do Not Connect) BI_DC- Receive Data- or Bi- Directional Pair C- BI_DB- Transmit Data- or Bi- Directional Pair B- Reserved (Do Not Connect) BI_DD+ Receive Data- or Bi- Directional Pair D+ Reserved (Do Not Connect) BI_DD- Receive Data- or Bi-...
  • Page 33 Communication Ports 4.2 Fiber Optic Ethernet Ports RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 34: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM M2200 can be equipped with the following power supplies: NOTICE Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range. Power Sup- Input Range Internal Fuse...
  • Page 35: Copper Ethernet Port Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 36: Fiber Optic Ethernet Port Specifications

    All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. Operating Environment The RUGGEDCOM M2200 is rated to operate under the following environmental con- ditions.
  • Page 37: Dimension Drawings

    Technical Specifications 5.8 Dimension Drawings Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. Note Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stat- 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 38 Technical Specifications 5.8 Dimension Drawings 32.76 21.08 11.68 479.29 461.01 4.57 Figure 5.2 Rack Mount Dimensions RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 39 Technical Specifications 5.8 Dimension Drawings 467.4 275.6 482.6 Figure 5.3 Panel Mount Dimensions RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 40: Certification

    UL 60950-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 41: 6.1.3 Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 42: Iso

    Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 43 Certification 6.2 EMC and Environmental Type Tests EMC Type Tests per IEC 61850-3 Note • In the case of an all fiber port configuration, this product meets all Class 2 re- quirements. Otherwise, all Class 1 requirements are met for copper ports. •...
  • Page 44 5 kV   AC Power Ports   Siemens-specified severity levels EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM M2200 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
  • Page 45 Certification 6.2 EMC and Environmental Type Tests Description Test Levels HV Impulse Signal Ports 5 kV (Fail-Safe Relay Output) DC Power Ports 5 kV AC Power Ports 5 kV Dielectric Signal Ports 2 kV Strength DC Power Ports 2 kV AC Power Ports 2 kV Damped Os- Enclosure Ports...
  • Page 46 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels tional, Low Temperature Stor- age, Low Temperature Oper- ational, Temperature Shock Storage, Humidity, Accelera- tion, Salt Fog and Vibration MIL-STD-1275B Power Quality Per Standard RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 47 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM M2200 Installation Manual, 03/2020, C79000-G8976-1044-16...
  • Page 48 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...