Status and Statistics
Diagnostics
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
Cisco SFP-10GLRM
Cisco SFP-10GLR
The following XG passive cables (Twinax/DAC) are supported:
Cisco SFP-H10GCU1m
Cisco SFP-H10GCU3m
Cisco SFP-H10GCU5m
To view the results of optical tests, click Status and Statistics > Diagnostics > Optical
Module Status.
This page displays the following fields:
Port—Port number on which the SFP is connected.
Description—Description of optical transceiver.
Serial Number—Serial number of optical transceiver.
PID—VLAN ID.
VID—ID of optical transceiver.
Temperature—Temperature (Celsius) at which the SFP is operating.
Voltage—SFPs operating voltage.
Current—SFPs current consumption.
Output Power—Transmitted optical power.
Input Power—Received optical power.
Transmitter Fault—Remote SFP reports signal loss. Values are True, False, and No
Signal (N/S).
Loss of Signal—Local SFP reports signal loss. Values are True and False.
Data Ready—SFP is operational. Values are True and False.
Tech-Support Information
This page provides a detailed log of the device status. This is valuable when the technical
support are trying to help a user with a problem, since it gives the output of many show
commands (including debug command) in a single command.