Cisco 1552S Installation Manual page 130

Hazardous locations
Table of Contents

Advertisement

Table E-3
Table E-3
Pin Number
1
2
3
6
4
5
7
8
Shield
Table E-4
Table E-4
Pin Number
1
2
3
6
4
5
7
8
Shield
The power injector output connector (To AP) only supplies 56 VDC power when the Ethernet cable is
Note
connected to the 1550 PoE In connector.
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
E-26
describes the pin signals for the power injector input connector (To Switch).
Power Injector Input Connector (To Switch) Pinouts
Signal Name
Ethernet signal pair (10/100/1000BASE-T)
Ethernet signal pair 10/100/1000BASE-T)
Ethernet signal pair (1000BASE-T)
Ethernet signal pair (1000BASE-T)
Chassis ground
describes the RJ-45 pin signals for the power injector output connector (To AP).
Power Injector Output Connector (To AP) Pinouts
Signal Name
Ethernet signal pair (10/100/1000BASE-T) and 56 VDC return
Ethernet signal pair (10/100/1000BASE-T) and 56 VDC (+)
Ethernet signal pair (1000BASE-T) and 56 VDC (+)
Ethernet signal pair (1000BASE-T) and 56 VDC return
Chassis ground