Troubleshooting
1
Diagnostic ACE Display Functions
1. Overlay decal (English shown)
2. "Inputs Displayed" LED (Red)
2
3.
"Outputs Displayed" LED (Green)
3
4. Toggle button
4
Figure 8b
Using "Inputs Displayed" (Red Text)
1
1. LED lit if oil level is too high
2
a.
2. LED lit if oil level is OK
3. LED lit if oil level is too low
3
4. LED lit if oil is too hot
4
5. LED lit if system air leak has been
detected
5
6. One or two LED's lit displaying
relative position of the Turfdefender's
6
b.
internal float.
7. "Inputs Displayed" LED "ON" (Red)
7
Normal Operation:
a. "Oil Level OK" LED lit
b. 1 or 2 LED's lit on left column
Figure 8c
Using "Outputs Displayed" (Green Text)
Normal Operation:
a. "Valve ON" LED lit steadily
b. "Self Diagnostic" LED lit steadily
c. "DATA LINE" LED lit steadily
d. "Alarm ON" LED lit temporarily
Problem Diagnosed:
The appropriate LED will blink to
identify the problem
Figure 8d
Page 5 – 8.4 Rev. B
Reelmaster 5100–D