hit counter script

Advertisement

Portable Air Conditioner
User Manual
Read and save these instructions before use
Model: HN Series
www.honeywellportableac.com
E-mail: info@honeywellportableac.com

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HN Series

  • Page 1 Portable Air Conditioner User Manual Read and save these instructions before use Model: HN Series www.honeywellportableac.com E-mail: info@honeywellportableac.com...
  • Page 2 SAFETY READ AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL.
  • Page 3 SAFETY (CONTINUED) • This appliance has been manufactured for use in domestic environments and should not be used for other purposes. • Only use the installation kit provided to install this unit. DO NOT attempt to extend the exhaust hose or install this unit using other methods other than that shown in this manual.
  • Page 4 THANK YOU Congratulations on your purchase of this Honeywell Portable Air Conditioner. Regarding the information pertaining to the installation, handling, servicing, cleaning and disposal of the appliance, please refer to the below paragraph of the manual. USER TIPS Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit.
  • Page 5: Parts Description

    PARTS DESCRIPTION 1) Control Panel 9) Lower Dust Filter 2) Casters 10) Lower Grill 3) Remote Control 11) Drain Tube (For Continuous Drain) 4) Exhaust Hose Connector 12) Lower Rubber Drain Plug (Air Conditioning Mode) 5) Cord Winder 13) Power Supply Cord 6) Upper Grill 7) Upper Dust Filter 8) Upper Rubber Drain Plug...
  • Page 6: Installation

    INSTALLATION It is important that the installation instructions below are followed for successful installation of this Portable Air Conditioner. Please call Customer Support if you have any difficulties or queries regarding these installation procedures. Installation Kit: 1. Window Bracket Kit (1 Set) 4.
  • Page 7 INSTALLATION (CONTINUED) Note: After setting the window bracket to the size of your window, please remove it from the window and follow the instructions below. 3. Connect the exhaust hose to the hose connector on back of the unit. Slide-in the hose connector downwards until it is locked in place.
  • Page 8 INSTALLATION (CONTINUED) IMPORTANT: Do not replace or lengthen the exhaust hose as this could cause the unit to malfunction. 50 cm / 20" Not Recommended Recommended WARNING: Any warranties included with this product will be voided if an extra extension hose is added to the originally provided installation kit or if the installation is performed differently than the manufacturer's instructions, without proper consultation.
  • Page 9: Use And Operation

    USE & OPERATION CONTROL PANEL (3) (1) (6) (5) (3) (1) (6) (5) HIGH COOL POWER HIGH COOL POWER TIMER TIMER TIMER TIMER SLEEP SLEEP WATER WATER SLEEP SLEEP HEAT FULL FULL Model with Heat Mode Model without Heat Mode 1) Timer Control / Sleep Control 4) Mode Control 2) Fan Speed Control...
  • Page 10 USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) WATER FULL LIGHT Condensation may accumulate in the unit. If the bottom internal tank is full, the WATER FULL light will illuminate and an alarm will beep for 30 seconds. The unit will not operate until the water has been drained from the bottom drain plug (refer to Water Condensation Drainage).
  • Page 11 USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) MODE CONTROL Settings: COOL, DRY, FAN and HEAT*. The corresponding indicator light will illuminate to indicate the current mode setting. • Air Conditioning Mode (COOL) Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 16°C - 32°C (60°F - 90°F).
  • Page 12 USE & OPERATION (CONTINUED) REMOTE CONTROL The functions work the same as the Portable Air Conditioner's Control Panel. All key functions can be accessed from the remote control. Power Control ON / OFF Temperature / Timer Set • Used for adjusting the timer and temperature.
  • Page 13: Cleaning And Maintenance

    CLEANING & MAINTENANCE Appliance Maintenance: Turn off the appliance before disconnecting the power supply. Only clean the appliance with a soft dry cloth. Dust Filter Maintenance: The dust filter is to be cleaned every two weeks to maintain air cooling efficiency. Please follow the below instructions for cleaning the dust filters: Switch off and unplug the air conditioner from the electrical outlet.
  • Page 14: Water Condensation Drainage

    WATER CONDENSATION DRAINAGE When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the WATER FULL indicator illuminates with a red light). This indicates that the water condensation needs to be drained using the following procedures: Manual Draining in Cooling, Heating* &...
  • Page 15: Troubleshooting Guide

    TROUBLESHOOTING GUIDE The following troubleshooting guide addresses the most common problems. If problems persist, call customer support. Unplug and disconnect the appliance from the power source before attempting to troubleshoot. PROBLEM POSSIBLE CAUSE SOLUTION No electricity. Check for power. Batteries in the remote control need to be Change remote control batteries.
  • Page 16 TROUBLESHOOTING GUIDE (CONTINUED) PROBLEM POSSIBLE CAUSE SOLUTION A door or window is open. Make sure the window or door is closed. The dust filter is dirty. Clean the dust filter. The exhaust hose is Reinstall exhaust hose properly detached. (refer to Installation section). Runs but not Temperature setting is Reduce temperature setting on control panel.
  • Page 17: Error Code Guide

    ERROR CODE GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Heating function not Check that the Heating function has been activated. Heater* is not activated yet. will be illuminated when the switching ON Temperature setting Heater is switched ON. Increase temperature setting. is too low. *Applicable for models with Heating feature only.
  • Page 18 ERROR CODE GUIDE ERROR CODE ERROR POSSIBLE CAUSE "E1" Indoor temperature sensor failure (open circuit or short circuit). "E3" Evaporator temperature sensor failure (open circuit or short circuit). "P1" Water full alarm.
  • Page 19 JMATEK Limited Made in China © 2019 JMATEK Limited. All rights reserved. Manulife Financial Centre, The Honeywell Trademark is used under license Kwun Tong, Hong Kong from Honeywell International Inc. Phone: 852-2559-5522 Honeywell International Inc. makes no representations or warranties with respect to this product.

Table of Contents