hit counter script
Sealey G1050I Instructions

Sealey G1050I Instructions

Generator inverter 1050w/2000w 230v

Advertisement

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment.
Familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.
Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for
which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.
WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for connection
at any one time, the total must not exceed rated wattage of generator (see specifications).
WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient
ventilation.
WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),
it is imperative that the earth connector on the machine is connected with a low impedance connector to the local earth via an
earth spike or local protective earth conductor. This connection should only be attempted by a qualified electrician, after first
having consulted your local dealer.
DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the
generator compartment of a caravan, may result in fire or an explosion. No user performed modifications, including venting of
the exhaust and/or cooling ventilation, will eliminate the danger.
DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken:
before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from
the commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or
fatality, owing to a back-feed of electrical energy.
DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare
wires, terminals etc. Never allow any unqualified person to operate or service the generator.
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the
vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of
fuels.
WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow cool down time.
Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.
Keep non-essential persons away from the working area.
WARNING! Never start or stop the generator while electrical loads are connected. Start the engine, let it stabilise, then connect
the electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching off.
WARNING! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in
electric shock.
DO NOT use the generator for any purpose other than that for which it is designed.
DO NOT operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.
DO NOT over-fill fuel tank. Always leave room for fuel to expand.
DO NOT operate in the rain.
 DANGER! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk
of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltage only when
running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads.
Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.
DO NOT operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.
DO NOT store the generator with fuel in tank where petrol vapours might reach an open flame or spark.
© Jack Sealey Limited
INSTRUCTIONS FOR:
GENERATOR INVERTER 1050W/2000W 230V
G1050I, G2000I
MODEL No's:
Original Language Version
G1050I, G2000I
Issue: 1 - 06/06/14

Advertisement

Table of Contents
loading

Summary of Contents for Sealey G1050I

  • Page 1  which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer. WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for connection ...
  • Page 2: Specification

    Dimensions (L x W x H): ....480 x 290 x 415mm........555 x 330 x 460mm fig.1 fig.2 - G1050I fig.3 - G2000I 4.
  • Page 3: Operation

    When an electric motor is started, both the overload indicator LED (red) and the output indicator LED (green) may light simultaneously. If the overload indicator LED (red) goes off after about four seconds, this is normal. If the overload indicator LED (red) stays on, consult your Sealey dealer. 6.4.
  • Page 4: Maintenance

    7.1.6. Reinstall the maintenance cover and tighten the cover screw securely. 7.1.7. Engine oil capacity: G1050I: Approx ∙18ltr, G2000I: Approx ∙35ltr. For normal temperatures, a 10W-30 oil is recommended. 7.1.8. Dispose of used oil responsibly, complying with local environmental regulations.
  • Page 5: Troubleshooting

    If being stored for a long period, drain the fuel tank. Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

This manual is also suitable for:

G2000i

Table of Contents