Work on the 110 V - 240 V supply system must be performed only by qualified personnel. Intended use This device integrates analog camera into the ABB Welcome door entry system. Up to four analog cameras can be connected to one camera interface. Each external camera is powered independently Environment...
® ABB Welcome Operation Control elements Fig. 1: Overview of control buttons Functions Bus in Bus out CVBS out Switch on camera power supply For details, please see Chapter 4.4 With and without permanent power supply. Working mode There are four modes for the camera interface. For details, please see Chapter 4.3 Operation mode.
® ABB Welcome Operating modes 4.2.1 Mode=1, works as an independent outdoor station Fig. 2: Mode=1, works as an independent outdoor station Rotary Value Note Mode Camera interface works as an independent camera interface. Addr null —— ID starts from 1 to 9 sequentially, and should not be the same address as the camera interface or any other camera interface.
® ABB Welcome 4.2.2 Mode=2, works associated with outdoor station Fig. 3: Mode=2, works associated with outdoor station Rotary Value Note Mode Camera interface work associated with outdoor station. Addr Address of the associated outdoor station, from 1-9. ID can be set from 1-9, and should be unique.
® ABB Welcome 4.2.3 Mode=3, works associated with guard unit Fig. 4: Mode=3, works associated with guard unit Rotary Value Note Mode Camera interface work associated with guard unit. Addr Address of guard unit, from 1-9. ID can be set from 1-9, and should be unique.
® ABB Welcome 4.2.4 Mode=4, programming mode Fig. 5: mode=4, programming mode Rotary Value Note Mode Camera interface works in programming mode. Camera interface mode, camera interface address and associated device Addr null address can all be programmed with software.
® ABB Welcome Programming mode start 1. Long press “Prog” button for 3 seconds to enter programming mode 2. Choose cameras to set by dip switch V1/V2/V3/V4 3. Assign the address of the camera interface by 4. Set the working mode by Mode=1, Camera interface works as an independent outdoor station.
® ABB Welcome Video signal from third party DVR Fig. 6: Video signal from third-party DVR Note: 1) DVR output can be one of the inputs for camera interface in modes 1, 2, 3 and 4. 2) Each camera interface supports four DVR signals.
® ABB Welcome Video signal to be stored to third-party DVR Fig. 7: Video signal to be stored to third-party DVR Note: 1) Camera interface sends video to video indoor station and also to DVR/TV through the CVBS output port.
® ABB Welcome Technical data Overview table Designation Value Single-wire clamps 2 x 22 AWG - 2 x 18 AWG Fine-wire clamps 2 x 22 AWG - 2 x 18 AWG Bus voltage 20 V - 30 V DC Protection...
® ABB Welcome Mounting and installation Warning Electric voltage! Direct or indirect contact with live components can cause dangerous currents to flow through the body, which may result in electric shock, burns or even death. Always disconnect the main power supply prior to installation and/or disassembly.
® ABB Welcome General installation instructions Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device). Do not install the system controller directly next to the bell transformer or other power supplies (to avoid interference).