No.
Parameter
24
G3 RX EQL
25
G3 TX EQL
26
CED & 300
27
COMM.STRT
28
EP TONE
29
TCF
30
NON-STANDARD
31
CSI TX
32
TSI / CIG TX
34
S-PROTOCOL
36
CODING
37
ECM
39
ERR LINE CNT
Selection
Default
Value
0 dB
8 dB
(Note 1)
4 dB
8 dB
12 dB
0 dB
0 dB
(Note 1)
4 dB
8 dB
12 dB
75 ms
75 ms
500 ms
1000 ms
1st DIS
1st DIS
2nd DIS
OFF
OFF
NSTD-C
NSTD-B&C
ALL-C
ALL-B&C
100ms+1s
200ms+1.2
s
100ms+1.2s
200ms+1s
200ms+1.2s
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
(B)
(B)
MH
MH/MR
MH/MR
OFF
ON
ON
32 lines
64 lines
64 lines
96 lines
128 lines
160 lines
192 lines
244 lines
255 lines
105
Description
Cable equalizer in G3 reception mode
Cable equalizer in G3 transmission mode
Pause time between CED and NSF/CSI/
DIS signal
Communication start up condition
1st DIS Starting up with the first reception of
the NSF and DIS.
2nd DIS Starting up with the second recep-
tion of the NSF and DIS.
Echo protect tone on V.29 mode
The TCF signal dscard and checking time
NSF and NSS signal transmission
Off : G3 standard mode
On : G3 non-standard mode
CSI signal transmission
Off : Not transmitted
On : Transmitted
TSI and CIG signal transmission
Off :Not transmitted
On : Transmitted
Short Protocol B
Off : Not used
(B) : Used
Select coding method.
Error Line Counter
When the machine detects the error lines
equal to or more than the line number set
the machine will disconnect the line.
UF-E1