hit counter script

Error Messages With The "Filehandler" Program - Siemens MOBY series User Manual

Stg hand-held terminal
Table of Contents

Advertisement

Available languages

Available languages

Error Messages
8.2
Error Messages with the "FILEHANDLER"
Program
The following table lists the messages which can occur with the filehandler. A
filehandler error message looks like this.
Type of error
(see chap. 8.1)
Exact filehandler error
Filehandler
Description of Error, Its Cause and Correction
Error
A006
Unknown command. Command identifier KK is illegal.
A011
With 1st command block: DBN not 1
With next block: KK or DBN incorrect
A015
Checkbyte error while receiving from S5
A016
Command from other sender is being processed.
A020
Wrong number of characters in the telegram
B001
Error in the connection to the SLG
Read head defective
C002
Error on RAM of the MDS. Replace MDS and perform
FORMAT.
C006
Presence error. MDS in boundary area.
C007
Parameterization error during FORMAT. Command
cannot be interpreted.
C008
Too many sync attempts. Field interference on read
head.
C009
Too many sending errors
C010
CRC sending error
C011
FORMAT. CRC error while receiving.
C012
FORMAT. MDS cannot be initialized.
C013
FORMAT, timeout. MDS in boundary area.
C014
FORMAT, not initialized. Check Extras/Parameter.
C015
CMD address error. Check Extras/Parameter.
C016
ECC error. Format MDS again. Disable ECC mode.
C017
General driver error
E-66
The filehandler error is shown in the same way
as the filehandler on the SIMATIC. The error
message has one alpha character followed by a
3-position number. Most of the error codes are
identical with the error numbers of all MOBY file-
handler interfaces.
(5)J31069-D0126-U001-A5.1-7418
R 01.04
Type of
Error
Protocol
Protocol
errors
SLG errors
MDS errors
STG Hand-Held Terminal

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Moby eMoby dMoby uMoby fMoby i

Table of Contents