hit counter script
Download Print this page
Cisco TelePresence Profile 55 Installation
Hide thumbs Also See for TelePresence Profile 55:

Advertisement

Quick Links

Installing Cisco TelePresence System Profile 42"/55"
PRofile 42"/55" ConTAins:
Monitor
Bottom module:
• Column
• Foot module (stand-alone, wheelbase
or wall mount)
Front grille (inside foot module box)
Speaker grille (inside monitor box)
Camera
Microphones, 2 or 3 pcs.
Touch 8" interface device
Remote control
Cables, screws and tools
Cleaning cloth
1
Unpacking the foot module (stand-alone, wall mount or wheelbase)
1.
Open the snap lockers.
2.
Lift out the foot module box.
3.
Open the box and unpack the
foot module.
Foot module box
The fooT ModUle Box ConTAins:
• Foot module (stand-alone, wall
• Four M8×30 screws
mount or wheelbase)
(wheelbase only)
• Front grille (not for wheelbase)
• Wall brackets and four M6×10
screws (wall mount only)
• Four M8×50 screws (not for
wheelbase)
3
A + B:
Mounting the stand-alone or the wall mount foot modules
to complete the bottom module
CAUTion:
Two persons working together are required to
mount the column to the foot module. Take care to hold
the modules firmly during installation.
1.
Unpack the column. Hold it firmly while moving the foot
module towards the bottom of the column, aligning the
holes for the screws.
2.
Fasten the four M8×50 screws with the
Allen key.
3.
Raise the bottom module.
78-20439-01 Profile 42-55 Installation Sheet | 2011 OCTOBER | © 2011 Cisco Systems, Inc. All rights reserved.
Rev. Date
Prep.
Checked Change
A
Stand-alone foot module (55 lb /25 kg)
heAVy
CAUTion
Lift out to open
the snap lockers.
B
Wall mount foot module
C
Wheelbase foot module
• Allen key
• Torx key (not for wheelbase)
• Level adjustment tool
(stand-alone only)
fAsTening The fRonT gRille
The front grille is attached using one M6×16 screw (upper
screw) and one M6×10 screw (lower screw) on each side,
as illustrated to the right. Use the Torx key.
The grille and Torx key are found in the foot module box. The
screws are pre-mounted in the grille and bottom module.
Follow these steps to fasten the grille:
1.
Remove the two upper screws from the grille.
2.
Loosen the two lower screws in the bottom module
without removing them.
3.
Place the front grille below the front door, as illustrated
to the right. Tilt the front grille to get the brackets
behind the front door and slide the grille on to the
lower screws.
4.
Open the front door to gain access to the screws.
a)
Insert the upper screws without tightening them.
b)
Close the front door to align the grille.
c)
Open the front door again, and tighten the lower
screws through the hole.
d)
Tighten the upper screws.
PReCAUTions
Please follow the steps in this installation guide when unpacking
and assembling Profile 42"/55". At least two (2) persons working
together are required when installing the system.
UnPACking The sysTeM AT The desTinATion
It is highly recommended to start the unpacking and assembling
of Profile 42"/55" at the place where the system is to be used.
noTe:
If it is not possible to bring the complete delivery to the
room where Profile 42"/55" is to be used, then unpack (step 1–2)
and bring the smaller units to the destination.
• The monitor box requires two (2) persons to lift
(42" 110 lb / 50 kg; 55" 121 lb / 55 kg)
• The column requires two (2) persons to lift (55 lb / 25 kg)
• The stand-alone foot module requires two (2) persons to lift
(55 lb / 25 kg)
2
Removing the outer cover and locating the boxes for the monitor, column, camera, touch screen and accessories
heAVy
Front
CAUTion
Monitor
(42" 110 lb / 50 kg,
55" 121 lb / 55 kg)
Column
(55 lb / 25 kg)
Front
heAVy
CAUTion
Front
Detailed illustration from inside, left
hand side. Right hand side is similar.
Upper screw
(M6×16)
Hole to access
the lower screw
Front grille
Lower screw
(M6×10)
Detailed illustration, left hand side.
Right hand side is similar.
Page 1
insTAllATion neAR A soCkeT-oUTleT
The equipment must be installed near a socket-outlet. The
socket-outlet shall be easily accessible after installation.
RooM gUidelines
noTe:
The floor must be in level.
The recommended distance between the Profile 42"/55" and
the meeting room table should be minimum 59 in. / 150 cm.
Read more about room guidelines in the Video conferencing room
primer.
UseR doCUMenTATion
The user documentation for this product, including compliance
and safety information, is available on the Cisco web site.
Go to: http://www.cisco.com/go/telepresence/docs.
Rev. Date
Prep.
Checked Change
The ACCessoRies Box ConTAins:
Telecom AS
Sheet 1 of 1
Processes
Tolerances
Specification:
Material
-
Type:
European
121608 rev.
-
Manufacturer:
-
projection
-
Type number:
-
Thickness:
-
Unit:
mm
Dimensions without paint or finish
Color:
-
Sheet size:
A3
All materials, finishes, and proccesses
Surface:
-
must comply with the RoHS directives
Glossiness:
-
Scale:
1:7
Flame class:
-
3D CAD model file 121608 rev. 01 is master
Part weight:
g
Flame class requirement: -
UL reference:
-
3
C:
Mounting the wheelbase foot module
CAUTion:
Two persons working together are
required to mount the column to the wheelbase. Take
care to hold the modules firmly during installation.
1.
Unpack the column. Hold it firmly while moving
the wheelbase towards the bottom of the column,
aligning the holes for the screws.
2.
Use the Allen key, which is
found in the foot module
box, to fasten the four
Front door
M8×30 screws.
3.
Raise the complete
bottom module.
Telecom AS
Sheet 2 of 2
Processes
Tolerances
Speci cation:
Material
Surface treatment
-
Type:
-
-
European
117324 rev.00A+
-
Manufacturer:
-
-
projection
-
Type number:
-
-
Thickness:
-
-
TANDBERG Aquarius 52"
mm
Dimensions without paint or nish
Unit:
Color:
-
-
Sheet size:
A3
All materials, nishes, and proccesses
Surface:
-
-
Glossiness:
-
-
Scale:
1:5
must comply with the RoHS directives
Flame class:
-
-
3D CAD model le 117324
rev. 00E+ is master
Part weight:
53908g
Flame class requirement: -
UL reference:
-
-
Rev. Date
Prep.
Checked Change
Telecom AS
117324 rev.00A+
TANDBERG Aquarius 52"
diMensions of PRofile 42"
The assembled unit has the following dimensions:
• Height: 59.9 in. / 152 cm
• Width: 38.6 in. / 98 cm
• Depth: Stand-alone: 26.8 in. / 68 cm
Wall mount: 8.9 in. / 23 cm (brackets included)
Wheelbase: 31.8 in. / 81 cm
• Weight: 232 lb / 105 kg
diMensions of PRofile 55"
The assembled unit has the following dimensions:
• Height: 64.6 in. / 164 cm
• Width: 49.6 in. / 126 cm
• Depth: The same as Profile 42"
• Weight: 245 lb / 111 kg
Touch controller
Camera
Accessories box
Surface treatment
-
-
-
• Microphones, 2 or 3 pcs.
-
• Cleaning cloth
-
-
-
-
• Remote control and 4 AAA
-
• Power cables
batteries
• Two M8×60 screws
Sheet 1 of 2
Processes
Tolerances
Specification:
Material
Surface treatment
-
Type:
-
-
European
-
Manufacturer:
-
-
projection
-
Type number:
-
-
Thickness:
-
-
Unit:
mm
Dimensions without paint or finish
Color:
-
-

Advertisement

loading

Summary of Contents for Cisco TelePresence Profile 55

  • Page 1 Flame class requirement: - UL reference: Right hand side is similar. Rev. Date Prep. Checked Change 78-20439-01 Profile 42-55 Installation Sheet | 2011 OCTOBER | © 2011 Cisco Systems, Inc. All rights reserved. Page 1 Telecom AS Sheet 1 of 2 Processes Tolerances...
  • Page 2 1:20 Flame class: 3D CAD model le 117324 rev. 00E+ is master Part weight: 85203g Flame class requirement: - UL reference: 78-20439-01 Profile 42-55 Installation Sheet | 2011 OCTOBER | © 2011 Cisco Systems, Inc. All rights reserved. Page 2...

This manual is also suitable for:

Telepresence profile 42