TC-32LX50 / TC-26LX50
7.2.
MTS Adjustment
7.2.1.
Input level adjustment
Instrument Name
Filter Jig
RMS voltage meter
RF signal generator
1. Apply following RF at Antenna input.
Video: Flat field, 30% modulation
Audio: 300Hz, 100% modulation, monaural
(70dB ±5dB, 75W OPEN, P/S 10dB)
Note: Make sure 75us Pre -Emphasis is off.
2. Select MTSIN of MTS adjust in factory adjust mode
3. Adjust "MTSIN" data (input level) until RMS voltage meter indicates 106±6mVrms.
Connect to
Monitor out L
Filter Jig
RF ANT. Input
Procedure
18
Remarks
Remarks
*Need to min 30 minutes aging.