Chapter 2 Installation

Installing the SM/LCM

Overview

You must perform the following steps to install the SM/LCM in a Model GS7000
Node, Hub Node, or Optical Hub.
1
Open the housing.
2
Install the SM/LCM in its correct position in the housing lid.
3
Press and hold the Auto Set-Up button until the Status and Fault LEDs stay on
(solid light) to start the discovery process.
4
Close the housing.
The following sections describe each of these steps in detail.

Opening the Housing

Open the housing as follows.
1
Remove the bolts securing the lid to the base.
2
Carefully open the lid to allow access to the inside of the housing.
3
Inspect gaskets on the cover flange and on the test port plugs.
4
Replace any gaskets showing signs of wear (cracked, twisted, pinched, or dry)
with new, silicon-lubricated gaskets.

Installing the Module

Complete the following steps to install the SM/LCM.
1
Inspect the pins on the electrical connector on the rear panel of the SM/LCM
module prior to inserting the module in the node.
Note: If the pins are not straight and level, the module should be returned to the
factory. Refer to Chapter 6, Customer Support Information, for information on
obtaining support and returning products.
12
CAUTION:
Make sure that all pins on the connector are straight and also level, i.e., they
are all at the same height. If not, damage may result to the connector pins
upon installation, installation may be impeded, or the module may not
function properly.