Closing the Housing

Close the housing as follows.
1
Ensure any worn gaskets are replaced, and the gaskets are clean and in the
correct position.
2
Carefully close the lid.
3
For strand-mounted housings, pull the lid away from the base and remove the
slack from the hinge before rotating the lid up toward the base.
4
Ensure no cables are pinched between lid and base.
5
Secure lid to base with bolts. Tighten from 5 to 12 ft-lbs (6.8 to 16.3 Nm) in the
sequence shown in the following illustration. Repeat the sequence twice, ending
with the final torque specification.

Node Power Limitations

Nodes and hub nodes must be configured in a manner that prevents potential
thermal overloads. Heat generated by the node can reduce the life of the equipment.
CAUTION:
The life of the equipment may be reduced if configured to draw more than the
recommended level of power from the power supplies.
OL-29937-01
CAUTION:
Use caution when closing the housing. Improper closing may result in the unit
not being sealed from the environment.
Installing the SM/LCM