Honeywell Activ8 PIR Installation Instructions
Honeywell Activ8 PIR Installation Instructions

Honeywell Activ8 PIR Installation Instructions

Pir motion detector with pet immunity up to 25kg

Advertisement

Quick Links

8IR103
PIR MOTION DETECTOR
With PET IMMUNITY up to 25Kg
INSTALLATION INSTRUCTIONS
English
P/N 7101507 REV. B A.Y.
Activ8 PIR FEATURES
FEATURES
Quad Linear Imaging Technology for
sharp analysis of body dimensions and
differentiation from background and
animals.
New ASIC based electronics.
Immunity to animals up to 25kg (55 lbs).
18m Detection Range with Wide Angle
Lens.
Temperature compensation.
Compact Design for Residential
Installation.
Variable pulse width adjustment.
Sensitivity adjustment.
Environmental immunity.
Height installation calibration
free (1.8m – 2.4m).
LED Remote function.
REMOVAL OF FRONT COVER
Unscrew the holding
screw and open base
TERMINAL BLOCK CONNECTIONS
Terminals 1 & 6 - Marked EOL
option.
Terminals 2 & 3 - Marked TAMPER
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will
be sent to the control unit.
The Activ8 PIR detector uses a special
designed optical Lens with unique Quad
(Four element) PIR Sensor and new ASIC
based electronics optimized to eliminate false
alarms, caused by small animals and Pets.
The Activ8 PIR provides unprecedented
levels of immunity against visible light.
The Detector offers an exceptional level of
detection capability and stability for every
security installation.
The Activ8 PIR is supplied with Wide Angle
DETECTION PATTERN
1. To remove the front cover, unscrew the holding
screw and gently raise the front cover.
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
3. Break out the desired holes for proper
installation.
4. The circular and rectangular indentations at the
bottom base are the knockout holes for wire
entry. You may also use mounting holes that
are not in use for running the wiring into the
detector.(For option with bracket - lead wire
through the bracket)
5. Mount the detector base to the wall, corner or
ceiling. (For option with bracket install bracket).
6. Reinstall the PC board by fully tightening the
holding screw. Connect wire to terminal block.
7. Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
DETECTOR INSTALLATION
Terminals 4 & 5 - Marked
These are the output relay contacts of the
detector. Connect to a normally closed zone in
the control panel.
Terminal 7 - Marked + (+12V)
End of line
Connect to a positive Voltage output of 8.2 -
16Vdc source (usually from the alarm control
unit)
Terminal 8 - Marked - (GND)
Connect to the negative Voltage output or ground
of the control panel.
PRODUCT DESCRIPTION
lens.
SELECT MOUNTING LOCATION
Choose a location most likely to intercept an
intruder. See detection pattern. The Quad high
quality sensor detects motion crossing the beam;
it is less sensitive detecting motion towards the
detector.
The Activ8 PIR performs best when provided
with a constant and stable environment.
AVOID THE FOLLOWING LOCATIONS
MOUNTING THE DETECTOR
KNOCKOUT HOLES
C
C
PCB LAYOUT
RELAY
The Activ8 PIR provides Pet immunity up
to 25Kg (55 lbs). For better immunity
avoid installation in areas where pets can
reach upwards.
TYPICAL INSTALLATION
Facing direct sunlight.
Facing areas subject to rapid
temperature changes.
Areas with air ducts or substantial air
flows.
A. Wire access
A
holes
A
D
B. Use for flat
A
wall
mounting
B
C
B
C. Corner
mounting -
use all 4
holes. Sharp
left or right
C
angle
mounting -
use 2 holes
B
B
(top and
bottom)
D. For bracket
mounting