For modules with order number 7MH4930-0AA01 Contents Hardware Requirements ....................3 Siwarex MS connections ....................6 Establish the communication to the Siwarex MS module ..........8 Adjustment with an adjustment weight................9 Set the SIWATOOL parameters................9 Adjustment procedure ..................12 Adjustment without an adjustment weight (theoretical adjustment) ......14 Create a Siwatool backup file ..................18...
1. Hardware Requirements Following hardware parts and software are requested to integrate a scale into SIMATIC S7-200: SIWAREX MS module, 24V Power Module, S7-200 CPU, SIWATOOL MS configuration package, RS232 cable, computer with Windows XP or higher and a calibration weight bigger than 5% of the sum of the nominal value of all load cells.
Ensure that the scale is empty (not loaded) and execute the command Adjustment zero valid (3). The Siwarex MS module shows now the weight value “0”. 7 Calibration Procedure Ensure that the scale is empty (not loaded) and click Adjustment zero valid (3).
Page 13
Afterwards, place the adjustment weight on the scale and execute the command Adjustment weight 1 valid (4). With executing of this command, the adjustment line is detected of the scale. The Siwarex MS module shows now the adjustment weight. Adjustment Weight The adjustment is completed now.
6. Create a Siwatool backup file Eventually you may save all parameter settings of the Siwarex MS module into a file Receive all data from the Siwarex MS module the Siwatool software: During the transmission from the Siwarex MS module to the PC, the following message-...
Page 19
(for any method, product or equipment) or implication by or from Siemens AG. Partial or full replication or translation of this document without written permission from Siemens AG is illegal.