Upper tension control dial
Standard
• A thread tension amount between 0.05 and 0.1N (5 and 10g) should be measured at dial position 0.
Adjustment
1. Remove the tension dial sheet
and the stopring
.
2. Remove the tension dial
.
3. Turn the adjusting nut
left or right to make adjustment.
4. Remount the tension dial at zero position then the stopring and the tension dial sheet.
Note: Cotton thread #50 should be used when adjusting the tension.
Do not include take up spring torque.