Cards Features and Functions
This chapter describes Cisco ONS 15600 card features and functions.
Chapter topics include:
2.1 Card Overview
When working with cards, wear the supplied ESD wristband to avoid ESD damage to the card. Plug the
Caution
wristband cable into the ESD jack located on the lower-left outside edge of the shelf assembly.
2.1.1 Card Summary
Table 2-1
Card
TSC Card
SSXC Card
2.1 Card Overview, page 2-1
2.2 TSC Card, page 2-3
2.3 SSXC Card, page 2-6
2.4 OC48/STM16 LR/LH 16 Port 1550 Card, page 2-8
2.5 OC48/STM16 SR/SH 16 Port 1310 Card, page 2-11
2.6 OC192/STM64 LR/LH 4 Port 1550 Card, page 2-14
2.7 OC192/STM64 SR/SH 4 Port 1310 Card, page 2-17
2.8 ASAP Card, page 2-20
2.9 Filler Card, page 2-24
2.10 SFP Modules, page 2-25
ONS 15600 Cards and Descriptions
Description
The timing and shelf controller (TSC) card performs
all system-timing functions for each ONS 15600.
The single shelf cross-connect card (SSXC) is the
central element for ONS 15600 switching.
C H A P T E R
For Additional Information...
See the
"2.2 TSC Card"
section on page
See the
"2.3 SSXC Card"
section on page 2-6
Cisco ONS 15600 Reference Manual, R5.0
2
2-3.
2-1

Advertisement

Table of Contents
loading

Summary of Contents for Cisco ONS 15600

  • Page 1 C H A P T E R Cards Features and Functions This chapter describes Cisco ONS 15600 card features and functions. Chapter topics include: 2.1 Card Overview, page 2-1 • 2.2 TSC Card, page 2-3 • 2.3 SSXC Card, page 2-6 •...
  • Page 2: Card Compatibility

    2-24 2.1.2 Card Compatibility This section lists ONS 15600 cards and their compatible software versions. In the table below, “Yes” means the cards are compatible with the listed software versons. Table cells with dashes mean cards are not compatible with the listed software versions.
  • Page 3: Tsc Slots And Connectors

    Cards Features and Functions 2.2 TSC Card 2.2 TSC Card Do not operate the ONS 15600 with a single TSC card or a single SSXC card installed. Always operate Caution the shelf with one active card and one protect card.
  • Page 4: Tsc Faceplate And Block Diagram

    CR, MJ, MN visual alarm 16 x alarm inputs 16 x alarm outputs Lamp test Mate LAN Mate control BITS 1 12 x STS-3 BITS 2 8 x line clock Mate timing control LAMP TEST RESET Cisco ONS 15600 Reference Manual, R5.0...
  • Page 5: Tsc Card-Level Indicators

    ACO button, the amber ACO LED turns on. The ACO button opens the audible closure on the backplane. The ACO state is stopped if a new alarm occurs. After the originating alarm is cleared, the ACO LED and audible alarm control are reset. Cisco ONS 15600 Reference Manual, R5.0...
  • Page 6: Tsc Push-Button Switches

    The RESET button is recessed to prevent accidental activation. Note 2.3 SSXC Card The single shelf cross-connect card (SSXC) is the central element for ONS 15600 switching. The SSXC card establishes connections and performs time division switching (TDS) at STS-1 and STS-Nc levels between ONS 15600 traffic cards.
  • Page 7: Ssxc Faceplate And Block Diagram

    2.3.3 SSXC Faceplate and Block Diagram Figure 2-2 shows the SSXC card faceplate and a block diagram of the card. Figure 2-2 SSXC Card Faceplate and Block Diagram SSXC 128 x C-STS-48 128 x C-STS-48 Cisco ONS 15600 Reference Manual, R5.0...
  • Page 8: Ssxc Card-Level Indicators

    You can install OC48/STM16 LR/LH 16 Port 1550 cards in Slots 1 through 4 and 11 through 14. The card provides four bidirectional OGI type connector adapters on the faceplate (angled downward), each carrying eight fiber strands (4 transmit and 4 receive). Cisco ONS 15600 Reference Manual, R5.0...
  • Page 9: Oc48/Stm16 Lr/Lh 16 Port 1550 Faceplate And Block Diagram

    OC48/STM16 LR/LH 16 Port 1550 Faceplate and Block Diagram OC48/STM16 LR/LH 16 PORT 1550 STAT LASER ON C-STS-48 copy 0 OC48 C-STS-48 copy 1 16 x OC-48 16 x OC-48 C-STS-48 copy 0 C-STS-48 copy 1 Cisco ONS 15600 Reference Manual, R5.0...
  • Page 10: Oc48/Stm16 Lr/Lh 16 Port 1550 Card-Level Indicators

    Receive 1 Transmit 8 Receive 8 Transmit 7 Receive 7 Transmit 6 Receive 6 Transmit 5 Receive 5 Transmit 12 Receive 12 Transmit 11 Receive 11 Transmit 10 Receive 10 Transmit 9 Receive 9 Cisco ONS 15600 Reference Manual, R5.0 2-10...
  • Page 11: Oc48/Stm16 Sr/Sh 16 Port 1310 Card

    You can install OC48/STM16 SR/SH 16 Port 1310 cards in Slots 1 through 4 and 11 through 14. The card provides four bidirectional OGI type connector adapters on the faceplate (angled downward), each carrying eight fiber strands (4 transmit and 4 receive). Cisco ONS 15600 Reference Manual, R5.0 2-11...
  • Page 12: Oc48/Stm16 Sr/Sh 16 Port 1310 Faceplate And Block Diagram

    OC48/STM16 SR/SH 16 Port 1310 Faceplate and Block Diagram OC48/STM16 SR/SH 16 PORT 1310 STAT LASER ON C-STS-48 copy 0 OC48 C-STS-48 copy 1 16 x OC-48 16 x OC-48 C-STS-48 copy 0 C-STS-48 copy 1 Cisco ONS 15600 Reference Manual, R5.0 2-12...
  • Page 13: Oc48/Stm16 Sr/Sh 16 Port 1310 Card-Level Indicators

    Receive 1 Transmit 8 Receive 8 Transmit 7 Receive 7 Transmit 6 Receive 6 Transmit 5 Receive 5 Transmit 12 Receive 12 Transmit 11 Receive 11 Transmit 10 Receive 10 Transmit 9 Receive 9 Cisco ONS 15600 Reference Manual, R5.0 2-13...
  • Page 14 (1 transmit and 1 receive). Only one transmit and receive pair is used per connector adapter. On a breakout cable, use port three, fiber 4 (transmit) and fiber 3 (receive). Cisco ONS 15600 Reference Manual, R5.0 2-14...
  • Page 15 STAT LASER ON C-STS-48 copy A OC192 C-STS-48 copy B 4 x OC-192 4 x OC-192 C-STS-48 copy A C-STS-48 copy B Note: Each C-STS-192 is split into four C-STS-48s for cross-connect purposes. Cisco ONS 15600 Reference Manual, R5.0 2-15...
  • Page 16 OGI Pin and Card Port — — Transmit 1 Receive 1 — — — — — — Transmit 2 Receive 2 — — — — — — Transmit 3 Receive 3 — — — — Cisco ONS 15600 Reference Manual, R5.0 2-16...
  • Page 17 (1 transmit and 1 receive). Only one transmit and receive pair is used per connector adapter. On a breakout cable, use port three, fiber 4 (transmit) and fiber 3 (receive). Cisco ONS 15600 Reference Manual, R5.0 2-17...
  • Page 18 Indicates a hardware fault; this LED is off during normal operation. Replace the unit if the STAT LED persists. During diagnostics, the LED will flash quickly during initialization and flash slowly during configuration synchronization. Cisco ONS 15600 Reference Manual, R5.0 2-18...
  • Page 19 — — — — — Transmit 2 Receive 2 — — — — — — Transmit 3 Receive 3 — — — — — — Transmit 4 Receive 4 — — — — Cisco ONS 15600 Reference Manual, R5.0 2-19...
  • Page 20 2.8.1 ASAP Slots and Connectors You can install ASAP carrier modules in Slots 1 through 4 and 11 through 14. Each 4PIO module can accomodate up to four SFPs, and each SFP has a female LC connector. Cisco ONS 15600 Reference Manual, R5.0 2-20...
  • Page 21: Asap Card Faceplate And Block Diagram

    PLDs ASAP CC 1 16xSFP 4xASAP 4PIO ASAP CC 2 ASAP 16xSFP 4xASAP 4PIO ASAP CC 3 4P IO 16xSFP 4xASAP 4PIO ASAP CC 7 CP 1 16xSFP 4xASAP 4PIO ASAP CC 8 Cisco ONS 15600 Reference Manual, R5.0 2-21...
  • Page 22: 4Pio Module Faceplate

    2.8.5 ASAP Card Port-Level Indicators Table 2-21 describes the functions of the port-level LEDs (numbered 1 through 4) on the 4PIO modules, depending on whether the port is configured for SONET or Ethernet. Cisco ONS 15600 Reference Manual, R5.0 2-22...
  • Page 23 Amber indicates that the link has an issue inhibiting traffic, such as a signal error, or disabled or unprovisioned port. Indicates a signal failure. Indicates a signal failure. Indicates that the port is unprovisioned. Indicates that there is no link. Cisco ONS 15600 Reference Manual, R5.0 2-23...
  • Page 24: Filler Card

    2.9 Filler Card The filler card is used to fill unused optical (OC-N) traffic card slots in the ONS 15600 shelf. In Software Release 1.1 the Filler card has a card presence indicator (CPI) that allows the shelf to report the presence of the filler card to CTC.
  • Page 25: Sfp Modules

    ONS 15600 Filler Card 2.10 SFP Modules This section describes the Small Form-Factor Pluggables (SFPs) that can be used with the ONS 15600 ASAP card. SFPs are also generically known as PPMs (Pluggable Port Modules) in the CTC software interface.
  • Page 26: Sfp Description

    Chapter 2 Cards Features and Functions 2.10.2 SFP Description Use only SFPs certified for use in Cisco Optical Networking Systems. The qualified Cisco SFP Caution pluggable module’s top assembly numbers (TANs) are provided in Table 2-22. Table 2-22 SFP Card Compatibility...
  • Page 27 Chapter 2 Cards Features and Functions 2.10.2 SFP Description Figure 2-12 Actuator/Button SFP Figure 2-13 Bail Clasp SFP Cisco ONS 15600 Reference Manual, R5.0 2-27...
  • Page 28 Chapter 2 Cards Features and Functions 2.10.2 SFP Description Cisco ONS 15600 Reference Manual, R5.0 2-28...