Dear Customer, ® Thank you very much for having chosen METPOINT OCV DATA LOG software. Please read this ® installation and operating manual carefully before installing and using the METPOINT OCV DATA ® LOG and follow our directions. Proper operation of the METPOINT OCV DATA LOG is guaranteed only if the instructions and directions specified are strictly observed.
Page 3
1 Contents Contents ..............................3 General information ..........................4 Scope of application and proper use ...................... 4 System and function description ......................5 System requirements..........................5 ® Connecting the network / notebook to METPOINT OCV ..............6 ® Installing and setting METPOINT OCV DATA LOG ................
2 General information Before reading the operating manual check whether you have the right manual at hand. The operating manual must be accessibly available at all times at the site where the software is being used. To ensure a secure transfer of data, the software must be installed and used solely in accordance with the specifications in the operating manual.
4 System and function description ® The METPOINT OCV DATA LOG software is used for displaying, remotely analysing and storing ® the measured values collected using METPOINT OCV. ® Displaying and storing the measured values for residual oil content ascertained using METPOINT OCV can be done on a directly connected notebook/PC and on a notebook/PC connected via the web.
Page 6
® 6 Connecting the network / notebook to METPOINT ® Connect the interface for your network / notebook to the METPOINT OCV (1) Ethernet interface intended for it using a corresponding network cable. It should be noted that the connection from the device to the notebook is made using a crossover cable.
® 7 Installing and setting METPOINT OCV DATA LOG ® This chapter describes the connections and settings that must be made for the METPOINT DATA LOG software to operate properly. NOTE! ® Administrator rights are mandatory for installing the METPOINT OCV DATA LOG software.
"Network" selection Select the desired method in the menu sub-item NETWORK: • Automatic IP address assignment via DHCP • Manual IP address assignment. To use this selection, go to main menu SETTINGS and then select NETWORK. Connection via DHCP If connection via DHCP is selected, no additional settings are required. This is based on the prerequisite that the connected network has a DHCP server.
Manual network connection Here, the network connection data must be entered manually. The following entries are required: • IP address • Net mask • Gateway address It must be ensured that different IP addresses are assigned to all devices in the network.
Establishing a direct connection to a notebook / PC The connection from the device to the notebook is established using a crossover cable. A direct connection to a notebook can also be established by means of manual configuration or automatic address assignment via DHCP (Auto-IP). mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 –...
Manual connection to a notebook / PC Important note! When establishing a manual connection, ensure that the IP addresses of device and notebook are different in the device portion of the IP address. ® 1. Please check the network settings on METPOINT OCV.
Page 12
5. Now click on "Properties" button. Internet protocol TCP/IP". This selection may require 6. In the following window, select item " you to scroll the list down. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
Page 13
7. Now click on "Properties" button. Important note! Before making any changes in the visible window, please write down the current settings and values of the notebook / PC. 8. Click on "Use the following IP address". mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
Page 14
9. Now enter the addresses in the corresponding fields. For example: IP address: 192.168.1.200 Subnet: 255.255.255.0 Important note! ® Ensure that PC / notebook and METPOINT OCV do not have the same IP address! mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
Page 15
10. Click on "Use the following DNS server". 11. Next, please click on "OK". mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
Page 16
12. Next, please click on "OK " 13. Next, please click on "Close". ® Now all the settings for the connection have been performed. The METPOINT OCV DATA-LOG software can now be used according to the following operating manual. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
® 8 The METPOINT OCV DATA LOG program Installation and start of METPOINT® OCV DATA LOG ® To use METPOINT OCV DATA LOG, the program must be installed from the CD-ROM provided. To do so, insert CD into the CD drive of your PC or notebook. If your autostart function is activated, the installation program will start automatically.
Start screen ® After the METPOINT OCV DATALOG program is started, the following appears on the screen: The program has 4 basic functions: • IMPORT + VIEWER SCREENSHOT • • LIVE • FIRMWARE UPDATE. A detailed description of the individual functions can be found on the following pages. Furthermore, you will find 2 additional display elements on the start screen.
8.2.2 Language selection ® The METPOINT OCV DATALOG program is available in two languages. A language selection can be made between German and English. The current language setting is indicated in the right upper corner of the screen. Use the drop-down menu to change the language setting by clicking on the desired language. After successful change, the following note appears: The language selection will automatically be adapted when program is restarted.
The LIVE function This view shows the current measured value and average of the last 10 measurement cycles, as well as the respective compressed air quality class according to ISO 8573, or the development of the measured values. ® OCV. For this purpose, select the LIVE function and First establish a connection to a METPOINT activate the drop-down menu "Select device".
Page 21
® As soon as the next measured value appears on the METPOINT OCV, the information is transferred in LIVE view. In addition to the display of the measured value, the development of the measured value can also be shown. For this purpose, select the Data diagram tab. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 –...
The standard setting shows 3 different measured value curves: Measured value Moving average Average 8.3.1 Data diagram adaptation Several functions are available to adapt the view of the data diagram Use the right mouse button for this. Use the left mouse button to select the displayed functions from the provided selection menu.
Page 23
If the function "Show Point Values" is activated, the individual measured values can be displayed in the Data diagram via the mouse. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
The SCREENSHOT function The SCREENSHOT function makes it possible to store and further process the current ® METPOINT OCV display. ® First select a METPOINT OCV from the drop-down menu "Select Device". Clicking on the camera symbol gives you a preview of your screen shot on the right side under the heading "Full Size".
The FIRMWARE UPDATE function ® The FIRMWARE UPDATE function can be used to update the METPOINT OCV firmware. As a rule, these tasks are performed during routine calibration and maintenance of the devices or, in exceptional cases, by our service. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 –...
The IMPORT + VIEWER function ® The METPOINT OCV setting is such that it automatically creates log files from the measured values and stores them in the internal memory. This program allows access to these log files during operation. The IMPORT + VIEWER area includes 3 functions: Automatic import •...
8.6.1 Selection of data All three IMPORT + VIEWER functions require the definition of specific periods for the transaction selected. To do so, use the timeline located above the individual selection menus. By double-clicking on the year, the period can be limited to the year selected. Additional double-clicks can limit the period to the desired month, day or hours.
Page 28
To extend the period again, the blue bar is elongated accordingly. After this, the endpoints of the timeline can be moved to the desired start and end position. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
8.6.2 The AUTOMATIC IMPORT function When selecting the AUTOMATIC IMPORT function, the following input screen appears: First, go to "Synchronisation Folder" to specify the storage location for saving the measurement data. Next, the program will create a subfolder with the name METPOINT XXX (e.g. METPOINT 124) in the file folder selected.
Page 30
Use the timeline to select the period for which you would like to check the measured values (see chapter 8.6.1 Selection of data Then select "Start". Now data download is performed. You can see the progress of the download on the screen. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 –...
Page 31
After the download is complete, the measured value file is automatically opened. It is also possible to make several downloads in parallel. Use the file tabs to switch between the individual download views. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 – 0422 www.BekoSales.com | Sales@BekoSales.com...
Page 32
In addition, the log files are saved in the selected file folder. The measured values are stored under "Meas". Next, sorting is by year, month and day. A subfolder is only created if a measurement was started on the corresponding day. The file name begins with the start time of the measurement, followed by the [#] symbol and the substance measured.
8.6.3 The SINGLE FILE IMPORT function This function allows access and graphic display of saved log files. For this purpose, click on "Single File Import" and select the network path that leads to the location of your log files. Next, select the desired file and double-click to confirm. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 –...
Page 34
The file is opened and shown in diagram form. It is also possible to perform a single import of several files. Use the file tabs to switch between the individual import screens. The data diagrams can be adapted by means of different functions. Also see chapter 8.3.1 Data diagram and chapter 8.6.1 Selection of data.
8.6.4 The MULTIPLE FILE IMPORT function The MULTIPLE FILE IMPORT function makes it possible to import multiple measured value files, optionally into one or several diagrams. Select "Multiple File Import". Use the drop-down menu to select whether all measured value files are to be imported into a graph, or whether a graph is to be created for each file.
Page 36
Select the desired file folder or the desired file. If the variant "One graph per file" has been selected, single file diagrams are displayed. Use the tabs to switch between files or delete single files. When using the variant "All files in one graph", the data are accordingly combined, and one data diagram is displayed.
Data export in EXCEL Generally it is possible to export the measurement data into an EXCEL spreadsheet. In the process, it is possible to select whether the entire file or the selected area is to be exported. Export entire diagram into EXCEL. Export selected area into EXCEL.
Page 38
To export the selected or all data, click on the corresponding symbol. Now you can specify the directory path and the file name. To confirm this step, click on "Save"; the measurement data are then exported into an EXCEL spreadsheet. mdi - Manufacturers Distributor, Inc Phone: (727) 835 - 0670 | Fax: (813) 571 –...
Page 39
During data export, the device number is always transferred as well. The EXCEL file can be accessed and opened like any regular file. Example: Measured values METPOINT_244 Residual oil content in Date/time mg/m³ 01.08.2012 04:21 0.5216 01.08.2012 04:23 0.5237 01.08.2012 04:37 0.5237 01.08.2012 04:48 0.5180...