CHAPTER 3 DISASSEMBLY & REASSEMBLY
4. DC power supply PCB
1)
Remove the rear cover.
2)
Remove six screws
power supply PCB
Screw
DC power supply PCB
Fig. 3-506
3)
Unhook two connectors
DC power supply PCB
DC power supply PCB
Connector
Fig. 3-507
3 - 40
and pull out the DC
.
and detach the
.
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
4)
Remove four screws (with round-shaped tips)
and detach the panel
Screw
Fig. 3-508
Precautions during the assembly
• The power switch should be in the OFF position
(in which the tip of the switch sticks out).
Connect connector 4P to CN1.
• Since the tips of the three screws that fix the
panel will protrude, use the screws with
round-shaped tips to prevent injuries.
Panel