hit counter script
Siemens SITRANS LR 200 Quick Start Manual
Siemens SITRANS LR 200 Quick Start Manual

Siemens SITRANS LR 200 Quick Start Manual

Radar
Hide thumbs Also See for SITRANS LR 200:

Advertisement

LR-200QS-EN.fm Page 1 Wednesday, March 12, 2003 3:51 PM
SITRANS LR 200 Quick Start Manual
This manual outlines the essential features and functions of the SITRANS LR 200. We strongly
advise you to acquire the detailed version of the manual so you can use your device to its fullest
potential. The complete manual is available on our Web site: www.siemens-milltronics.com.
The printed manual is available from your local Siemens Milltronics representative.
Questions about the contents of this manual can be directed to:
Siemens Milltronics Process Instruments Inc.
1954 Technology Drive, P .O. Box 4225
Peterborough, Ontario, Canada, K9J 7B1
Email: techpubs@siemens-milltronics.com
Copyright Siemens Milltronics
Process Instruments Inc. 2003.
All Rights Reserved
We encourage users to purchase
authorized bound manuals, or to view
electronic versions as designed and
authored by Siemens Milltronics Process
Instruments Inc. Siemens Milltronics
Process Instruments Inc. will not be
responsible for the contents of partial or
whole reproductions of either bound or
electronic versions.
MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc.
Safety Guidelines
Warning notices must be observed to ensure personal safety as well as that of others, and to
protect the product and the connected equipment. These warning notices are accompanied by
a clarification of the level of caution to be observed.
WARNING: relates to a caution symbol on the product, and means that
failure to observe the necessary precautions can result in death, serious
injury, and/or considerable material damage.
WARNING: means that failure to observe the necessary precautions can
result in death, serious injury, and/or considerable material damage.
CAUTION: means that failure to observe the necessary precautions can result
in considerable material damage.
Note:
means important information about the product or that part of the operating manual.
7ML19985QL81
Disclaimer of Liability
While we have verified the contents of this manual
for agreement with the instrumentation described,
variations remain possible. Thus we cannot
guarantee full agreement. The contents of this
manual are regularly reviewed and corrections are
included in subsequent editions. We welcome all
suggestions for improvement.
Technical data subject to change.
SITRANS LR 200 – QUICK START MANUAL
Page EN-1

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS LR 200

  • Page 1 SITRANS LR 200 Quick Start Manual This manual outlines the essential features and functions of the SITRANS LR 200. We strongly advise you to acquire the detailed version of the manual so you can use your device to its fullest potential.
  • Page 2: Specifications

    SITRANS LR 200 is to be used only in the manner outlined in this manual, otherwise protection provided by the equipment may be impaired.
  • Page 3: Installation

    Avoid proximity to high voltage or current wiring, high voltage or current contacts, and to variable frequency motor speed controllers. • Avoid interference to the emission cone from obstructions or from the fill path. 7ML19985QL81 SITRANS LR 200 – QUICK START MANUAL Page EN-3...
  • Page 4: Connecting Sitrans Lr 200

    Separate cables and conduits may be required to conform to standard instrumentation wiring practices, or electrical codes. If cable is routed through conduit, use only approved suitable-size hubs for waterproof application. Page EN-4 SITRANS LR 200 – QUICK START MANUAL 7ML19985QL81...
  • Page 5: Run Mode Display

    SITRANS LR 200 has 2 modes of operation: RUN and PROGRAM. After you complete the installation procedures and power up SITRANS LR 200, it starts in RUN mode and detects the distance to the material level in meters. This is the default start-up display mode.
  • Page 6: Program Mode Display

    If you are programming from a distance, you can use either a HART handheld communicator or a PC running Simatic PDM. Hand programmer For direct access to SITRANS LR 200, point the programmer at the SITRANS LR 200 display and press the keys. Programming Mode...
  • Page 7: Activating Sitrans Lr 200

    LR-200QS-EN.fm Page 7 Wednesday, March 12, 2003 3:51 PM Activating SITRANS LR 200 Power up the instrument. SITRANS LR 200 starts in RUN mode. Accessing a parameter Notes: • Press PROGRAM then DISPLAY to access PROGRAM mode, and press PROGRAM to return to RUN mode.
  • Page 8 (P001 = 2) (P001 = 3) (4 mA) (4 mA) (20 mA) Span Span Distance Span 100% Space P006 P007 Level Empty Empty 100% Empty 100% (20 mA) (20 mA) (4 mA) Page EN-8 SITRANS LR 200 – QUICK START MANUAL 7ML19985QL81...
  • Page 9 P837 (Auto False Echo Suppression. (0% Level) Empty Use "learned" TVT Value Note: "Learn" • P006 and P007 are interlinked: see notes attached to P007. Default setting for Blanking is 0.4 m 7ML19985QL81 SITRANS LR 200 – QUICK START MANUAL Page EN-9...
  • Page 10: Maintenance

    Notes: • Use this function only if there is a minimum distance of 2 meters from SITRANS LR 200 to the material. • Set P837 and P838 during start up, if possible.
  • Page 11: Instructions Specific To Hazardous Area Installations (Reference European Atex Directive 94/9/Ec, Annex Ii, 1/0/6)

    If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. 7ML19985QL81 SITRANS LR 200 – QUICK START MANUAL Page EN-11...
  • Page 12 LR-200QS-EN.fm Page 12 Wednesday, March 12, 2003 3:51 PM Aggressive substances: e.g. acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. Suitable precautions: e.g. regular checks as part of routine inspections or establishing from the material’s data sheet that it is resistant to specific chemicals.

Table of Contents