Chapter 4
Troubleshooting
Table 4-1
Common Problems and Their Solutions (continued)
Symptom
No connectivity
78-16057-01
Possible Cause
Incorrect or bad cable
These are results of no link at both
ends:
A crossover cable was used
•
when a straight-through was
required, or the reverse.
The cable is wired incorrectly.
•
A crossover or straight-through
•
cable is wired incorrectly.
STP checking for possible
•
loops.
Catalyst 3560 Switch Hardware Installation Guide
Diagnosing Problems
Resolution
For the correct pinouts and
•
the proper application of
crossover vs.
straight-through cables, see
the
"Two Twisted-Pair
Cable Pinouts" section on
page
B-5.
•
Enable the automatic
medium-dependent-
interface crossover
(Auto-MDIX) feature.
Many legacy powered
Note
devices, including older
Cisco IP phones and
access points that do not
fully support IEEE
802.3AF, might not
support PoE when
connected to the
switches by a crossover
cable.
Replace with a tested good
•
cable.
For 1000BASE-T
•
connections, be sure to use
a twisted four-pair,
Category 5 cable.
Wait 30 seconds for the port
•
LED to turn green.
4-5