How to Install or Remove the Power Components
1
2
Prerequisites
Before performing this task, make sure that the PDU has been installed (see the
section on page
Required Tools and Equipment
You need the following tools and part to perform this task:
•
•
•
Steps
To install a power module, follow these steps:
Step 1
Attach the ESD-preventive wrist strap to your wrist and connect its leash to one of the ESD connection
sockets on the front (PLIM) side of the chassis or a bare metal surface on the chassis.
Step 2
Make sure that the power switch is in the off position.
Step 3
Grasp the handle on the top of the module firmly, and lift it partway up.
Step 4
Using two hands to support and guide the power module, slide it into the chassis power bay on the front
(PLIM) side of the chassis until the connector on the back of the module meets the connector on the
backplane of the PDU.
Caution
Press the power module in firmly to seat it against the PDU.
Step 5
Caution
Tighten the two captive screws on the face of the power module to seat it snugly against the PDU.
Step 6
Push the power tab at the bottom front of the module in to the on position.
Step 7
Cisco ASR 14000 Series Router 8-Slot Line Card Chassis Installation Guide
2-14
Power switch
Module air filter
2-10) and remove any cosmetic covers.
ESD-preventive wrist strap
Medium Phillips screwdriver
Power module
ASR14KAC rectifier Cisco product number ASR14K-8-AC-RECT=
–
DC PEM Cisco product number ASR14K-8-DC-PEM=
–
An AC rectifier weighs 36 lbs (13.44 kg); a DC PEM weighs 38 lbs (17.24 kg). You should
use both hands when handling a power module.
To prevent damage to the PDU-to-module connections, do not use excessive force when
seating a power module to its PDU.
Chapter 2
Installing and Removing Power Components
3
Handle
4
Captive screws
"Installing a PDU"
OL-16973-01