hit counter script

Information Codes Table (For Facsimile) - Panasonic UF-5500 Service Manual

Hide thumbs Also See for UF-5500:
Table of Contents

Advertisement

11.2.8. Information Codes Table (For Facsimile)

Code
Mode
Phase
001
007
012
021
030
031
041
043
045
051
054
060
068
090
091
092
093
094
400
XMT
B
Fax Information Codes
Description of Problem
Timing Sensor did not turn ON within a
certain period of time.
Recording paper did not completely exit
from machine.
The received data overflows from the
maximum paper size of the paper feeding
direction.
The fixing temperature does not rise up
even if the heating circuit is "ON".
The temperature of fuser exceeds upper
limit of controllable temperature.
The cooling fun in the unit does not rotate.
Document is misfeeding.
Document paper is too long or jammed.
Document length exceeds 2 meters.
Out of toner.
Toner is getting low.
Drum Cartridge is not installed.
There is something wrong with DC motor.
The polygon motor does not become stable
within the specified time when the polygon
motor is "ON". The behavior of polygon
motor rotation become unturned on the
way.
Printer Cover is open.
Rear Cover is open.
Malfunction of high voltage unit.
Cooling down the fuser unit.
The drum cartridge is reaching the end of
its life.
The unit is operated under the low-
temperature environment which is not
covered under warranty.
Malfunction of drum cartridge.
T1 timer (35 ± 5 sec.) elapsed without
detecting 300 bps signal.
157
Cause
1. Recording paper jammed when feeding from
the 1st cassette.
2. The 1st cassette is not installed.
3. The 1st cassette has run out of paper.
4. Recording paper is not loaded in the 1st
cassette.
5. Drive Clutch defective.
6. Timing Sensor defective.
1. Recording Paper Jam.
2. Paper Exit Sensor defective.
Transmitter Document Jam.
1. Fuser Lamp connector is disconnected.
2. Fuser Unit defective.
3. Thermistor defective (Fuser Unit).
4. The cooling fun is defective.
1. Document is not set properly.
2. Defective Read Point Sensor.
1. The document may jam.
2. Defective Read Point Sensor.
1. No toner.
2. Defective Toner Sensor.
1. Toner is getting low.
2. Defective Toner Sensor.
1. Toner Cartridge has not been installed.
2. Defective Cartridge Sensor.
1. DC motor connector is disconnected.
2. DC motor is defective.
1. Polygon motor connector is disconnected.
2. The polygon motor defective.
3. LSU defective.
1. Cover is not firmly closed.
2. Connectors are not firmly connected.
1. Cover is not firmly closed.
2. Connectors are not firmly connected.
1. HVPS is defective.
2. Drum cartridge defective.
The fuser unit temperature is unstable. Wait until
the "PLEASE WAIT" is disappeared. This is nor-
mal operation.
1. The drum cartridge is reaching the end of its
life.
1. Thermistor defective (Operation Panel
Board).
1. Mixing Paddle defective.
2. Defective Toner Sensor.
Wrong number is dialed and the START button
is pushed.
Telephone line is disconnected while dialing.
MAIN PCB (Modem) is defective.
Receiver is defective. (It may only be transmit-
ting CED)
UF-5500 / 4500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf-4500

Table of Contents