B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 8 of 47)
ADDR
REGISTER NAME
350A
RTD Input 27 Value
350B
RTD Input 28 Value
350C
RTD Input 29 Value
350D
RTD Input 30 Value
350E
RTD Input 31 Value
B
350F
RTD Input 32 Value
3510
RTD Input 33 Value
3511
RTD Input 34 Value
3512
RTD Input 35 Value
3513
RTD Input 36 Value
3514
RTD Input 37 Value
3515
RTD Input 38 Value
3516
RTD Input 39 Value
3517
RTD Input 40 Value
3518
RTD Input 41 Value
3519
RTD Input 42 Value
351A
RTD Input 43 Value
351B
RTD Input 44 Value
351C
RTD Input 45 Value
351D
RTD Input 46 Value
351E
RTD Input 47 Value
351F
RTD Input 48 Value
Ohm Input Values (Read Only) (2 modules)
3520
Ohm Inputs 1 Value
3521
Ohm Inputs 2 Value
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (16 items)
3570
Direct Input States, one per register (96 items)
Field Units (Read/Write Setting) (8 modules)
3800
Field Unit 1 ID
3806
Field Unit 1 Function
3807
Field Unit 1 Type
3808
Field Unit 1 Serial Number
380E
Field Unit 1 Port
380F
...Repeated for Field Unit 2
381E
...Repeated for Filed Unit 3
382D
...Repeated for Filed Unit 4
383C
...Repeated for Filed Unit 5
384B
...Repeated for Filed Unit 6
385A
...Repeated for Filed Unit 7
3869
...Repeated for Filed Unit 8
Field Unit Process Card Ports (Read/Write Setting)
3878
Field Unit 1 Process Card Port
3879
Field Unit 2 Process Card Port
387A
Field Unit3 Process Card Port
387B
Field Unit 4 Process Card Port
387C
Field Unit 5 Process Card Port
387D
Field Unit 6 Process Card Port
387E
Field Unit 7 Process Card Port
387F
Field Unit 8 Process Card Port
Field Unit CT VT Settings (Read/Write Setting) (6 modules)
3890
Remote Phase CT x Origin 1
3891
Remote Phase CT x Origin 2
3892
Remote Ground CT x Origin 1
B-16
RANGE
UNITS
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
0 to 65535
Ohm
0 to 65535
Ohm
0 to 1
0 to 1
0 to 1
0 to 1
0 to 3
1 to1
1 to 4
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 16
0 to 16
0 to 16
C30 Controller System
APPENDIX B
STEP
FORMAT
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
1
F001
1
F001
---
1
F155
---
1
F108
---
1
F205
---
1
F102
---
1
F243
---
1
F205
"000000000000"
---
1
F001
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F247
---
1
F247
---
1
F248
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Offline)
0 (Off)
"U1"
0 (Disabled)
0 (CC-05)
1
6 (H1a)
4 (H2a)
2 (H3a)
0 (H4a)
7 (H1b)
5 (H2b)
3 (H3b)
1 (H4b)
0 (None)
0 (None)
0 (None)