Summary of Contents for Dell Networking S4810

  • Page 1 Dell Networking S4810 and Dell Force10 S4810 Switch Configuration Guide for EqualLogic SANs Dell Storage Engineering January 2016...
  • Page 2: Revisions

    THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. Copyright © 2012-2016 Dell Inc. All rights reserved. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
  • Page 3: Table Of Contents

    Configure additional switches ............................. 11 Reverting from DCB to non-DCB configuration (Optional) .................... 12 Disable DCB ................................... 12 Remove DCB policies and apply standard flow control ..................12 SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 4 Configure route for OOB management port (optional) ..................15 Configure login credentials ............................16 Configuring switch ports ............................. 16 5.10 Save configuration and reload ............................ 16 Additional resources ................................17 SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 5: Introduction

    Introduction This document illustrates how to configure Dell™ Networking S4810 and Dell Force10™ S4810 switches for use with EqualLogic™ PS Series storage using Dell best practices. The recommended configuration uses link aggregation groups (LAGs) for inter-switch connections. Optional steps are provided in Section 3 to enable Data Center Bridging (DCB) and for stack configurations.
  • Page 6: Cabling Diagram

    Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and EqualLogic arrays. Figure 1 Cabling diagram SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 7: Dell Recommended Switch Configuration

    Configure out of band (OOB) management port FTOS>enable After the startup configuration is deleted, the factory default Enable mode password is force10. FTOS>#config FTOS(conf)#interface ManagementEthernet 0/0 FTOS(conf-if-ma-0/0)#no shutdown FTOS(conf-if-ma-0/0)#ip address ipaddress mask FTOS(conf-if-ma-0/0)#exit SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 8: Configure Route For Oob Management Port (Optional)

    FTOS(conf -if-range-te-0/0-47)#no shutdown FTOS(conf -if-range-te-0/0-47)#exit FTOS(conf)#exit Enable Jumbo Frames FTOS#configure FTOS(conf)# interface range tengigabitethernet 0/0 – 47 FTOS(conf -if-range-te-0/0-47)#mtu 12000 Configure flow control FTOS(conf -if-range-te-0/0-47)#flowcontrol rx on tx off SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 9: Configure Spanning Tree On Edge Ports

    Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 10: Configure Data Center Bridging (Dcb) (Optional)

    Configure Data Center Bridging (DCB) (Optional) To enable DCB mode on the switch, use the following commands. Note: You must complete the Dell recommended switch configuration steps in Sections 2.1 to 2.12 before configuring the switch for DCB mode. Disable 802.3x flowcontrol on SFP+ ports...
  • Page 11: Configure Dcb Policies

    Note: The sum of the bandwidth-percentages must be equal to 100. Save configuration FTOS#copy running-config startup-config Configure additional switches Repeat the commands from section 3 to configure DCB on additional switches. SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 12: Reverting From Dcb To Non-Dcb Configuration (Optional)

    VLAN 100). If a non-default VLAN is configured, then any ports connected to the arrays must be configured as “untagged”. Note: Host NICS must also be updated with matching VLAN information. Use the steps below to configure the native VLAN on the switch. SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 13: Save Configuration

    Verify DCB status FTOS#show dcb Figure 2 Screen shot of show DCB Configure additional switch Repeat the commands from section 4 to disable DCB on any additional switches. SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 14: Optional Stack Configuration

    Delete startup configuration on the second switch FTOS>enable FTOS#delete startup-config Proceed to delete startup-config [confirm yes/no]yes FTOS#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 15: Configure Stack On The Second Switch

    If your management system is on the same subnet as the switch, the previous step may be omitted. The example above assumes a class C subnet mask. SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 16: Configure Login Credentials

    Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs...
  • Page 17: Additional Resources

    DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: ...