Siemens SCALANCE XR-300M Operating Instructions Manual
Siemens SCALANCE XR-300M Operating Instructions Manual

Siemens SCALANCE XR-300M Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XR-300M:
Table of Contents

Advertisement

Quick Links

SCALANCE XR-300M
SIMATIC NET
Industrial Ethernet switches
SCALANCE XR-300M
Compact Operating Instructions
05/2016
A5E02661171-11
___________________
Introduction
___________________
Safety notes
___________________
Description
___________________
Assembling
___________________
Connecting
___________________
Technical data
___________________
Dimension drawings
___________________
Approvals
___________________
Appendix
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XR-300M

  • Page 1 ___________________ SCALANCE XR-300M Introduction ___________________ Safety notes ___________________ SIMATIC NET Description ___________________ Assembling Industrial Ethernet switches SCALANCE XR-300M ___________________ Connecting ___________________ Technical data Compact Operating Instructions ___________________ Dimension drawings ___________________ Approvals ___________________ Appendix 05/2016 A5E02661171-11...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Installation of modular devices ....................32 4.7.1 Installation and removal of media modules ................32 4.7.2 SFP installation in SFP media module ................... 36 Connecting ............................39 Safety when connecting up ..................... 39 Notes on commissioning ......................41 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 4 XR-300M FDA and IEC approvals ..................68 Overview of XR-300M approvals ................... 68 XR-300M mechanical stability (in operation) ................. 69 Appendix .............................. 71 The connector system M12/X coded according to IEC 61076-2-109 ........71 Index ..............................73 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 5: Introduction

    Where can I find more detailed information on the product? A CD is supplied with the IE Switches X-300 on which you will find a detailed description of the products in PDF format in the relevant subfolder. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 6: Product Group Xr-300M

    Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions.
  • Page 7: Type Designations

    The type designation of an IE Switch X-300 is made up of several parts that have the following meaning: Interfaces of devices without optical ports: Interface Property Electrical RJ-45 port for 10/100 Mbps. Electrical RJ-45 port for 10/100 Mbps or 10/100/1000 Mbps. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 8 26 km in length. • Port 21: Multimode • Port 22: LD (long distance, single mode) • Port 23: LD (long distance, single mode) SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 9: Safety Notes

    This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 10: Important Notes On Using The Scalance X-300 Product Family

    General notices about use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 11: Compact Operating Instructions, 05/2016, A5E02661171

    Provisions shall be made to prevent the rated voltage from being exceeded by transient voltage surges of more than 40%. This criterion is fulfilled, if supplies are derived from SELV (Safety Extra-Low Voltage) only. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 12: Important Notes On Using The Device In Hazardous Areas

    Devices with a 100 to 240 VAC power supply do not have an ATEX approval. Devices with a 100 to 240 V AC power supply are not approved for use in hazardous areas according to EC-RL-94/9 (ATEX). SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 13: Pelv

    The supply of the devices by PELV (Protective Extra Low Voltage) according to DIN VDE 0100-410 or IEC 60364-4-41 is permitted when the generated nominal voltage does not exceed the voltage limits 25 VAC or 60 VDC. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 14 Safety notes 2.5 PELV SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 15: Description

    Labels to identify the installed MM900 media modules are supplied with the modular devices (M). The following parts ship with a SCALANCE XR-300M: ● Device with C-PLUG exchangeable medium. ● 2 mounting brackets and 8 screws (M3x5 recessed head, drive: Torx) for 19" rack installation.
  • Page 16: Product Group Xr-300M

    S12) depending on the application. End devices and other network segments are connected according to the modules being used. Note When shipped, the slots for the media modules have a dummy cover fitted. Image 3-1 SCALANCE XR324-12M with blind covers SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 17 The connection of end devices or other network segments does not depend on the module slot, but rather on the selected media module. Refer to the section Media module installation in slot. Image 3-2 SCALANCE XR324-12M with MM900 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 18: The Set / Select Button

    2. Hold down the SET/SELECT button for five seconds. After three seconds, the "DM" LED begins to flash. If you release the button before the five seconds have elapsed, the previous fault mask will be retained. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 19: Led Display

    LED color LED status Meaning The standby function is disabled. green The standby function is enabled. The standby section is passive. green flashes The standby function is enabled. The standby section is active. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 20 Whereas on other devices, the "L1" and "L2" LEDs indicate information about the power, on the SCALANCE X306-1LD FE, this is done by the "L" LED. A redundant power supply for this device can be recognized by the color of the LED. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 21 If the power supply is intact, a fault occurring on a power supply unit on the secondary side can be recognized. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 22 The port is monitored, in other words, if no connection was established at the port (for example no cable insert- ed), this triggers the signaling contact and an error state results. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 23: C-Plug

    Inserting a C-PLUG that does not contain the configuration of a compatible device type, accidentally removing the C-PLUG or general malfunctions of the C-PLUG are signaled by the diagnostics mechanisms of the device (LEDs, Web-based management, SNMP, CLI and PROFINET diagnostics). SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 24: Removal And Insertion Of The C-Plug (Rack Devices)

    3. The housing of the C-PLUG has a protruding ridge on the long side (position B). The slot has a groove at this position. Insert the C-PLUG correctly oriented into the slot. 4. Secure the cover plate again with the screws. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 25: Assembling

    Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 26: Suitable Cables For Temperatures Above 70 °C - Cable 50 °C - 70 °C (Atex)

    If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. When installing the device, select a location where only qualified service personnel or trained users have access to it. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 27: 19" Rack Mounting

    19" rack mounting WARNING Use of approved components • Use only approved 19" cabinets. • Use only supplied mounting brackets. There are several ways of fixing the mounting brackets depending on the mounting position required. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 28 60 °C without external ventilation NOTICE Four-point mounting If mechanical load is high, the device should be secured at four points. You will find more detailed information in the section "Mechanical stability in operation". SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 29 On the back of the housing, you will find the diagnostics port • of the device. (For more details, refer to Diagnostics port XR-300.) On the SCALANCE X-300M EEC, you will also find the connectors for the signaling contacts and power supply here. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 30 Connect the grounding bolts. On the SCALANCE X- 300EEC, the PE connector is on the bottom of the de- vice. On the SCALANCE XR-300M EEC, the PE con- nector is on the rear of the device between the power connectors.
  • Page 31 Removal Removing from the rack Turn off the power supply for the SCALANCE XR-300M. Disconnect all cables for data traffic and the connectors for the power supply and the grounding cable. Undo the screws on the mounting bracket and remove the rack device (R) from the 19" cabinet.
  • Page 32: Installation Of Modular Devices

    The following aspects can restrict the maximum permitted operating temperature: • The orientation of the carrier device. • The use of SFP transceivers. • The use of transceivers of the types LH, LH+ or ELH. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 33 Remove the protective caps only immediately before you use the plug-in connection. NOTICE Use only approved SFPs If you use components not approved by Siemens AG, in particular SFPs, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 34 The procedure for installation is identical for rack or compact devices. Select the required slot on the device (for example, X308-2M). Remove the dummy cover. Pull out the handle on the selected media module. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 35 1. Remove all connectors from the media module. 2. Pull out the handle of the media module and remove the media module from the device slot. 3. Secure the dummy cover. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 36: Sfp Installation In Sfp Media Module

    NOTICE Use only approved SFPs If you use SFPs that are not approved by Siemens AG, there is no guarantee that the device will function according to the specification. If you use unapproved SFPs, this can lead to the following problems: •...
  • Page 37: Removing An Sfp

    2. Open the clip on the SFP and remove the SFP from the SFP media module. Notice: It must be possible to remove the SFP easy without using force. 3. Fit a blind plug to the SFP. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 38 Assembling 4.7 Installation of modular devices SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 39: Connecting

    Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 40 Take measures to prevent transient voltage surges of more than 40% of the rated voltage. This is the case if you only operate devices with SELV (safety extra-low voltage). WARNING Before connecting up and commissioning the device, read the information in the section Auto-Hotspot SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 41: Notes On Commissioning

    Grounding (functional ground) is via the mounting bracket on the device or via the screw-in bolts on the rear of the device. To ground the device from the back, follow the steps below: 1 toothed washer 2 grounding bolt SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 42: Signaling Contact

    ● The signaling by the signaling contact is synchronized with the fault LED, in other words, all errors displayed by this LED (freely configurable) are also signaled on the signaling contact. ● If an internal fault occurs, the fault LED lights up and the signaling contact opens. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 43: 24 V Dc Signaling Contact

    Pin assignment of the 24 VDC signaling contact Pin number Assignment Pin 1 Pin 2 To wire up the signaling contact, use a copper cable of category 18-12 AWG or cable with a cross-section of 0.75 to 2.5 mm². SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 44: Diagnostics Port

    PC ships with the SCALANCE XR-300. Diagnostics port on the rear of the device Pin assignment The following table shows the pin assignment of the RJ-11 plug and the D sub female connector: Image 5-1 RJ-11 jack (schematic) SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 45: Power Supply

    • The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV), 24 VDC). • Never operate the device with AC voltage or DC voltage higher than 32 VDC. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 46 Pin 2 Pin 3 Pin 4 L2+ (24 VDC) To wire up the power connector, use a copper cable of category 18-12 AWG or cable with a cross-section of 0.75 to 2.5 mm². SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 47: Xr-300M Device Variants With 24 V Dc Power Supply

    No desktop operation of devices with 100 to 240 VAC power supply Devices with power supply 100 to 240 VAC may only be operated if they are installed in a 19" rack. Desktop operation is not permitted! SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 48: Fitting The Connector For 100 To 240 V Ac

    If this occurs, you will also not be able to connect all the wires in the connector. Open wire ends may be dangerous due to line voltage. Use only two-wire cables. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 49 Cut off the excess cable tie. 4. Fit the upper part of the housing. The housing is correctly mounted when the two catches audibly click into place and are flush with the surface of the housing. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 50: Connecting The 100 To 240 V Ac Power Supply

    Pin 1 L1 (100 to 240 VAC) Pin 2 To wire up the power connector, use a copper cable of category 18-12 AWG or cable with a cross-section of 0.75 to 2.5 mm². SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 51: Technical Data

    Desktop operation is permitted only for the 24 VDC variants of the rack devices (R). The adhesive feet ship with the 24 VDC variants. In this case, the permitted ambient temperature is -40 °C to +50 °C. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 52 -40 °C to +60 °C With more than 2 modules or other slot assign- SFP991-1LH+ ment: SFP992-1LH -40 °C to +50 °C SFP992-1LH+ SFP992-1ELH SFP991- Vertical -40 °C to +50 ℃ 1ELH200 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 53: Connectors And Electrical Data

    Rated voltage 24 VDC Voltage range 19.2 VDC - 28.8 Permitted voltage range 18.5 VDC - 30.2 incl. total ripple 1 x 100 to 240 VAC 100 to 240 VAC (85 to 264 VAC) SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 54: Cable Lengths

    0 to 75 m IE FC TP Trailing Cable + 10 m TP cord + 10 m TP cord IE FC TP Flexible Cable with IE FC RJ-45 Plug 180 0 to 85 m SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 55: Block Architecture

    ● Between the blocks there is a bandwidth of 1 gigabit/s available,that must be shared by all ports for frame traffic between the blocks. When operating solely with Fast Ethernet (100 Mbps), the XR devices support full wire speed via all blocks. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 56: Other Properties

    Block architecture of the XR324-12M Image 6-2 Block architecture of the XR324-4M Other properties Table 6- 13 Switching properties Max. number of learnable addresses 8000 Aging time 30 sec Switching technique Store and forward Latency 5 μs SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 57 At 100 Mbps At 1000 Mbps 148810 1488095 64 bytes 84459 844595 128 bytes 45290 452899 256 bytes 23496 234962 512 bytes 11973 119732 1024 bytes 9615 96154 1280 bytes 8127 81274 1518 bytes SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 58 • at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps) • at 1500 bytes frame length: Delay of approx. 130 microseconds (at 100 Mbps) This means, the more IE Switches X-300 a frame runs through, the higher the frame delay. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 59: Dimension Drawings

    Dimension drawings XR-300M dimension drawings Note The following dimension drawings are available for the XR-300M product group. Image 7-1 Front view of the XR324-12M SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 60 Dimension drawings 7.1 XR-300M dimension drawings Image 7-2 XR324-12M from above SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 61 Dimension drawings 7.1 XR-300M dimension drawings Image 7-3 XR324-12M from above SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 62 Dimension drawings 7.1 XR-300M dimension drawings SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 63: Approvals

    The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 64 (http://support.automation.siemens.com/WW/view/en/27069465)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
  • Page 65 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
  • Page 66 Only variants with 24 VDC power supply meet the requirements of this approval. cULus approval for industrial control equipment cULus Listed IND. CONT. EQ. Underwriters Laboratories Inc. complying with ● UL 508 ● CSA C22.2 No. 142-M1987 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 67: Scalance X-300 Declaration Of Conformity

    When used on railway stock, a stabilized power supply must be used to comply with EN50155. SCALANCE X-300 declaration of conformity You will find the EC Declaration of Conformity for these products on the Internet at the following address: SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 68: Xr-300M Fda And Iec Approvals

    The 24 V DC variants do not have an E1 approval. The 100 to 240 V AC variants have C-Tick and CE approvals but are only UL508 listed. They do not have UL hazloc, FM or ATEX approvals. SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 69: Xr-300M Mechanical Stability (In Operation)

    ( 2 x 24 VDC data cable outlet ● ● ● at rear) XR324-12M (1 x 100 to 240 VAC, data cable ● ● ● outlet at rear) *) Note: When rack mounted with 4 securing points SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 70 Approvals 8.5 XR-300M mechanical stability (in operation) SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 71: Appendix

    Signal White / orange White / orange Orange Orange White / green White / green Green Blue White / brown White / blue Brown Green White / blue White / brown Blue Brown SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 72 Appendix A.1 The connector system M12/X coded according to IEC 61076-2-109 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 73: Index

    Hazardous area, 10 Possible attachments SCALANCE XR324-12M, 16 Safety notices, 10 for installation, 25 general, 9 Use in hazardous areas, 9, 25, 39 when connecting up, 39 SIMATIC NET glossary, 6 System manual, 64 SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...
  • Page 74 Index SCALANCE XR-300M Compact Operating Instructions, 05/2016, A5E02661171-11...

Table of Contents