OPERATING CONTROLS HANDSET CONTROLS LINE 1 LED (Green) Antenna • Lights when the handset is used for LINE 2 LED (Orange) a phone conversation on line 1. • Lights when the handset is used for • Blinks when the base unit or a phone conversation on line 2.
ALIGNMENT PROCEDURE Test Mode For Base Unit Press the “ ” and “#” keys at the same time about 1.5 seconds while turning the power on, the confirmation beep will sound to indicate that the unit is in the test mode. 1.
Page 5
Test Mode For Handset Unit To perform the TEST mode, turn the power ON by pressing the “ ” and “#” buttons at the same time. When entered the TEST mode, the bell rings and the unit enters TEST mode 1 . ( Refer to the following table. ) 1.
Page 6
Base Unit Transmitter Section Connection BASE RF PCB BASE MAIN PCB AF GEN. Test Point Power Meter Test Point DC IN TEL Line 1kHz 61.0mV 9V Jack 1/2 Jack Test Point Frequency Counter AC 120V Adapter 60Hz Deviation Meter Preset Place the Base Unit in VCO/TX FREQ ADJ mode in accordance with the procedure on page 3.
Page 7
Receiver Section Connection BASE RF PCB BASE MAIN PCB AC Voltmeter RF SG Dummy Load (600-ohm) − − TEL Line DC IN 1/2 Jack Test Point 9V Jack DC Voltmeter AF Terminal AC 120V 60Hz Adapter Preset Place the Base Unit in RX SENS mode (step 4) in accordance with the procedure on page 3. Alignment Procedure Step Preset to...
Page 8
Handset Unit Transmitter Section Connection HANDSET MAIN PCB HANDSET RF PCB AF GEN. Test Point Power Meter Test Point Battery 1kHz 11.0mV MIC + Pin Terminals Test Point Frequency Counter DC Power Supply Deviation DC 3.8V Meter Preset Place the Handset in VCO/TX FREQ. ADJ mode in accordance with the procedure on page 4. Alignment Procedure Step Adjustment...
Page 9
Receiver Section Connection HANDSET RF PCB HANDSET MAIN PCB AC Voltmeter RF SG Dummy Load (150-ohm) J602 − − Battery Connector Test Point Terminals J601 DC Voltmeter DC Power Supply AF Terminal DC 3.8V Preset Place the Handset in RX SENS mode (step 4) in accordance with the procedure on page 4. Alignment Procedure Step Preset to...
TROUBLESHOOTING HINTS 1. The bell does not ring. When the INTCOM key of See 2. The bell does not the base is pressed, does ring & page does not ring. the ringer on the handset ring? When the TEL SG is joined Check IC3 (Line 1) or with the base to make bell IC12 (Line 2) and TEL network...
Page 20
2. The bell does not ring & page does not ring. See 3. The base and Can the base and handset handset cannot be be connected? connected. Press handset DIAL key When the key of the Check IC603. while in TALK MODE. handset is pressed, can the Can key touch sound be pulse output at pin 58 of...
Page 21
3. The base and handset cannot be connected. Check IC18 and its Check whether the base is peripheral circuit. able to set in the test mode 1. Check the TX POWER and Check base RF unit. the TX FREQUENCY on the base unit.
Page 22
Set the handset in the test Check whether there is a Check VR601, R619, R632, mode 3, check whether 250Hz data waveform at R634, R635, R636 deviation of the TX data is Pin 9 of J601. and C611. app. 7 kHz Dev. Check handset RF unit.
Page 23
4. Will not dial out. (TONE) Check whether there is a DTMF waveform on Pin 8 Check IC10 and IC6. (Line 1) or Pin 4 (Line 2) of IC6. Check whether there is a DTMF waveform on Pin 7 Check IC2 or IC11. of IC2 (Line 1) or Pin 1 of IC11 (Line 2).
Page 24
5. TROUBLE WITH INTERCOM MODE 5-1. The voice from the Base unit cannot be heard on the Handset. Check whether there is an Check MC401 and IC20. audio waveform on Pin 23 of IC20. Check Pin 2 of IC15. 5-2. The voice from the Handset cannot be heard on the Base unit. Check whether there is an Check IC15.
Page 25
6. TROUBLE WITH SPEAKERPHONE MODE 6-1. The voice of the caller cannot be heard (INCOMING CALL). Check IC1 (Line 1) or IC8 Check whether there is an (Line 2). audio waveform on Pin 11 of IC1 (Line 1) or Pin 8 of IC8 (Line 2).
EXPLODED VIEW AND MECHANICAL PARTS LIST Base, Unit Note: To remove the RF Assembly from the unit, remove four screws 24 . Three screws 23 are used for fastening the Shield Cases 26 and 27 . — 49 —...
Page 45
Base Unit LOC. PART NO. REF. NO. DESCRIPTION RC005685 GNBZ157880Z Button, Function RC005680 GCAS257882Z Case, Battery RC005678 GCAS157875Z Case, Bottom RC005677 GCAS157874Z Case, Top RC005686 HTML457884Z Charge Terminal C5191(PBP) RC002384 LFUT428079Z Foot Bumpon SJ-5916 1.6T RC005689 LHDZ453179Z Holder, Mic RC005444 HHDS431080Z Holder, Speaker SUS304-CSP,0.6T...
Page 46
Handset Note: To remove the RF Assembly from the unit, remove four screws 69 . Three screws 68 are used for fastening the Shield Cases 70 and 71 . — 51 —...
PARTS LIST PRODUCT SAFETY NOTE: Products marked with a have special characteristics important to safety. Before replacing any of these components, read carefully the product safety notice of this service manual. Don ’ t degrade the safety of the product through important servicing. Symbol Symbol ±...
Page 49
LOC. PART NO. DESCRIPTION RC004562 BCUB814725Z CERAMIC 0.0047UF 50V K B RC005667 BCUB811835Z CERAMIC 0.018UF 50V K B RC005667 BCUB811835Z CERAMIC 0.018UF 50V K B RC005635 BCKB134715Z CERAMIC 470PF 1000V K YB(B) RC004494 BCUB511045Z CERAMIC 0.1UF 25V K B RC004503 BCUP512240Z CERAMIC 0.22UF 25V Z F...
Page 50
LOC. PART NO. DESCRIPTION RC004481 BCUA811514Z CERAMIC 150PF 50V J CH RC004560 BCUB813325Z CERAMIC 0.0033UF 50V K B RC004560 BCUB813325Z CERAMIC 0.0033UF 50V K B RC004492 BCUA818204Z CERAMIC 82PF 50V J CH RC004138 BCAZ811006Z ELECTROLYTIC 10UF 50V M C-156 RC004739 BCUB813335Z CERAMIC 0.033UF 50V K B...
Page 51
LOC. PART NO. DESCRIPTION C129 RC001807 BCAZ812296Z ELECTROLYTIC 2.2UF 50V M C-156 C130 RC001794 BCAZ111016Z ELECTROLYTIC 100UF 10V M C-156 C131 RC005166 BCUP311050Z CERAMIC 1UF 16V Z F C132 RC004497 BCUB811035Z CERAMIC 0.01UF 50V K B C133 RC001794 BCAZ111016Z ELECTROLYTIC 100UF 10V M C-156 C134 RC004145...
Page 52
LOC. PART NO. DESCRIPTION C227 RC005202 BCML311045Z CERAMIC 0.1UF 16V K B C228 RC005214 BCMM812214Z CERAMIC 220PF 50V J CH C229 RC005225 BCSS114796Z TANTALUM CHIP TAPE 4.7UF 10V M A C-241 C230 RC005216 BCMM813304Z CERAMIC 33PF 50V J CH C231 RC005214 BCMM812214Z CERAMIC...
ASSEMBLY PARTS LIST NOTE: Following part numbers are not available as replacement parts. Order parts necessary for repair or contact the Toshiba Factory Service Center. LOC. PART NO. DESCRIPTION RC005630 AD840BLBA BASE MAIN ASSEMBLY RC005317 AD825ZLBB BASE RF ASSEMBLY RC005631...
SPECIFICATIONS Measurement Conditions Standard Voltage: Handset Unit DC 3.6 V ±0.025 V Base Unit AC 120 V ±3 V 60 Hz Temperature: 25 °C ±5 °C Channel: Handset (TX Frequency) Base (TX Frequency) 902.078145 MHz 925.999522 MHz 902.128199 MHz 926.049576 MHz 902.178254 MHz 926.099630 MHz 902.228308 MHz...
Page 72
Base Unit Receiver Unit Nominal Limit −115 < −107 Sensitivity 12dB SINAD (CCITT Filter ON) −0.5 −4.5 ~ +3.5 Frequency Response 0.3 kHz − 6 −10 ~ − 2 3.0 kHz Distortion at 1 mV RF Input < 5 S/N ratio at 1 mV RF Input (CCITT Filter ON, Compander ON) >...
Page 73
DTMF Output (600 Ω load) −7 > −10 a. Minimum Level On Single Tone Low Group −5 > −8 High Group −3 b. DTMF Level < 0 c. DTMF Frequency Row 1 687 ~ 707 Row 2 759 ~ 781 Row 3 840 ~ 864 Row 4...