hit counter script

Checking The Drives For Data Consistency - Asus Pedestal/5U Rackmount Server TS500-E5 User Manual

Asus ts500-e5 pedestal/5u rackmount server user guide
Hide thumbs Also See for Pedestal/5U Rackmount Server TS500-E5:
Table of Contents

Advertisement

6.2.6

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected logical
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the Objects > Adapter
menu.
The Check Consistency command is available only for logical drives included
in a RAID 1 set.
Using the Check Consistency
To check data consistency using the Check Consistency command:
From the Management Menu, select Check Consistency, then press
1.
<Enter>.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
2.
The screen displays the available RAID set(s) and prompts you to select the
logical drive to check. Press the <Spacebar> to select the logical drive from
the Logical Drive selection, then press <F10>.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Logical Drives
Loical Drive 0
ASUS TS500-E5
CC Of VD(s)
Logical Drive(s) Configured
LD
RAID
Size
0
10
154494MB
Select VD
SPACE-(De)Select, F10-Check Consistency
#Stripes
StripSz
4
64 KB
Status
ONLINE
6-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts500-e5 pa4Ts500-e5 rx8Ts500-e5

Table of Contents

Save PDF