Sign In
Upload
Manuals
Brands
Siemens Manuals
Accessories
TC12
Siemens TC12 Manuals
Manuals and User Guides for Siemens TC12. We have
1
Siemens TC12 manual available for free PDF download: Installation, Commissioning And Maintenance Handbook
Siemens TC12 Installation, Commissioning And Maintenance Handbook (203 pages)
Installation, Commissioning and Maintenance Handbook
Brand:
Siemens
| Category:
Accessories
| Size: 0.88 MB
Table of Contents
Table of Contents
6
1 Introduction
11
Purpose
11
Scope
11
Related Documents
11
Parent Documents
11
Kindred Documents
11
Reference Documents
11
Definitions
11
Issue State and Amendments
12
Tc12 System Overview
14
Figure 1 - System Diagram for Digital Output Rack Connection to Awall Map
18
Figure 2 - System Connection for Two Itu Racks
19
2 Tc12 Instation
20
Specification
20
Mains Voltage Ranges
20
Mains Frequency Range
20
Mains Current
20
Temperature and Humidity Requirements
20
Size and Weight
21
Figure 3 - Tc12 Cabinet - External Dimensions
21
Installation
22
Cabinet
22
Figure 4 - Tc12 Instation Pc Installation Screen (7.4)
29
Figure 5 - Tc12 Instation Pc Installation Screen (8.3 & Later)
29
Systems Fault Indication Panel (SIP)
32
19" Racking Pcbs
32
Figure 6 - Itu 19" Rack (Front View)
32
Figure 7 - Psu Board Layout
35
Figure 8 - Psu Board Switch Settings
36
Figure 9 - Psu Board Mains Voltage Range Setting
37
Figure 10 - Modem Pcb Layout
40
Table 1 - Modem Pcb Mode Select Switch (Sw1)
41
Table 2 - Modem Pcb Line Level Switches (Sw2, 3, 6 and 7)
42
Table 3 - Modem Pcb 2/4 Wire Select Switch (Sw4)
43
Table 4 - Modem Pcb Transformer Select Switch (Sw5)
43
Figure 11 - Transformer Pcb Layout
45
Figure 12 - Itu 19" Rack (Rear View)
45
Digital Output Rack, Pcbs and Psus
46
Figure 13 - Digital Output Pcb Layout
46
PSTN Modem
49
External Cables
49
Figure 14 - Modem Pcb - Mdf Connections
51
Figure 15 - Transformer Pcb - Mdf Connections
53
Commissioning
54
Safety Tests on the TC12 Instation
54
Commissioning Procedure after Power up
56
Maintenance
57
Status Leds
57
Effect of Incorrect Switch Settings on the PSU PCB
58
Figure 16 - Modem and Psu Pcb Status Leds
58
Effect of Incorrect Switch Settings on the Modem PCB
59
Effect of Incorrect Switch Settings on the Transformer PCB
60
Effect of Incorrect Switch Settings on the Digital Output Pcbs
60
Fault Finding at the Instation
60
Replacing Modem, Transformer and Digital Output Pcbs
62
TC12 Instation PC Help / Diagnostic Screens
62
Fuses
69
Psu
70
Figure 17 - Master Switch Panel Fuses
70
Digital Output PCB
71
Recommended Spares
71
3 Tc12 Outstation
72
Specification
72
Mains Voltage Ranges
72
Mains Frequency Range
72
Mains Current
72
Temperature and Humidity Requirements
72
Size and Weight
72
Detector Power Supply
72
Installation
72
General
72
Configuring the Outstation PCB
73
Figure 18 - Outstation Pcb Layout
74
Figure 19 - Outstation Pcb and Daughter Board Layout
74
Figure 20 - Otu Lithium Battery on / off Switch (S2)
77
Figure 21 - Otu 2/4 Wire Select Switch (S4)
77
Figure 22 - Otu 600 Ω High Impedance Switch (S6)
77
Figure 23 - Modem Daughter Card Jumper Positions
78
Table 5 - Otu Line Level Switch (S3)
78
Connectors and Cables
79
Figure 24 - Otu 6-Way Telecom Socket Connections
80
Figure 25 - Outstation Input Connections
83
Figure 26 - Outstation Output Connections
84
Figure 27 - Freestanding Outstation Inputs
86
Lamp Monitor Unit Connections
88
Figure 28 - Lmu Input Connector
88
Table 6 - Outstation Processor Pcb - Pl1
89
Current Transformer Ratings
90
Lamp Monitor Unit - Number of Current and Voltage Sensors
93
TC12 Outstation Mechanical Modules and Number of Detectors Supported
95
Commissioning
96
Safety Tests on the TC12 Outstation
96
Commissioning Procedure after Power up
97
Configuration Using the Handset
98
Examples of Lamp Monitor Unit Configuration Using the Handset
129
Figure 29 - Phases in Stages for Example 6
137
TCSU TC12 OTU Commissioning Procedure
140
Table 7 - Tcsu Default Configuration Values
141
Maintenance
142
Status Leds
142
Figure 30 - Outstation Pcb Status Leds
143
Effect of Incorrect Switch Settings on the OTU PCB
144
Fault Finding at the Outstation
144
Fuses
145
Lithium Battery
145
Psu
145
Figure 31 - Outstation Psu Voltage Checks
146
Recommended Spares
147
4 Tc12 Instation Test Set
148
Specification
148
Mains Voltage and Frequency Ranges
148
Mains Current
148
Size and Weight
148
Installation
149
Setting the Working Voltage Range of the Instation Test Set
149
TC12 Instation Test Set Software Installation
149
Error Messages During Test Set Software Start up
149
Terminal Emulation Software
150
Installation of Handset Software
150
Overview of the Tc12 Instation Test Set Settings/Selections and Connections
151
Introduction
151
Connection to Unit under Test
151
Front Panel Switches
152
Overview of Test Set Software Settings/Selections and Operation
155
Modes of Operation
155
Screens / Functions of the ITS
155
Using the Test Set for Fault Finding on Tc12 System
157
General
157
Starting up the Test Set
157
Fault Diagnosis
158
Using the Test Set as a Monitor for the Instation Pc
164
Using the Test Set as Handset
165
Maintenance of Instation Test Set
166
Recommended Spares
166
Periodic Testing
166
5 Tc12 Outstation Test Set
167
Specification
167
Mains Voltage and Frequency Ranges
167
Mains Current
167
Size and Weight
167
Using the Outstation Test Set
168
Facilities
168
Figure 32 - Outstation Test Set Front Panel
169
Figure 33 - Outstation Test Set Connections
170
Operation
173
General
173
OTU Mode (Simulating an Outstation)
173
Controller Mode (Simulating Traffic Control Equipment)
174
Maintenance
176
6 Integral Outstation Transmission Unit (Otu/Lmu)
177
General Overview
177
Specification
178
Mains Voltage and Frequency Ranges
178
Mains Current
178
Temperature and Humidity Requirements
178
Size
178
Installation
179
General
179
Configuring the Integral OTU PCB
179
Figure 34 - Integral Otu Pcb Layout and Switch Settings
180
Connectors and Cables
182
Table 8 - Integral Otu Line Level Switch (S3)
182
Table 9 - Integral Otu Pla - 40 Way Connector
182
Table 10 - Integral Otu Sk2 Sk3 - Test Jacks
183
Figure 35 - Lmu Input Connector
185
Lamp Monitor Unit - Number of Current and Voltage Sensors
188
Commissioning
189
Commissioning Procedure after Power up
189
Configuration Using the Handset
190
Examples of Lamp Monitor Unit Configuration Using the Handset
195
LMU Commissioning
198
Maintenance
201
Status Leds
201
Effect of Incorrect Switch Settings on the OTU PCB
201
Fault Finding at the Outstation
202
Lithium Battery
202
Recommended Spares
202
Advertisement
Advertisement
Related Products
Siemens TC63
Siemens SITRANS TS100
Siemens SITRANS TS200
Siemens SITRANS TS300
Siemens SITRANS TS500
Siemens SICLOCK TC100
Siemens TC865 series
Siemens TC3A...GB
Siemens TC805 SERIES
Siemens GAMMA instabus Touch control TC5
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL