Sign In
Upload
Manuals
Brands
Huawei Manuals
Chiller
NetCol5000-C080
Huawei NetCol5000-C080 Manuals
Manuals and User Guides for Huawei NetCol5000-C080. We have
2
Huawei NetCol5000-C080 manuals available for free PDF download: User Manual, Quick Manual
Huawei NetCol5000-C080 User Manual (219 pages)
In-row Chilled Water Smart Cooling Product
Brand:
Huawei
| Category:
Chiller
| Size: 10.31 MB
Table of Contents
About this Document
3
Table of Contents
5
1 Safety Information
9
General Safety
9
Personnel Requirements
12
Electrical Safety
12
Installation Environment Requirements
14
Mechanical Safety
15
Cooling System Safety
18
Others
18
2 Product Description
19
Model Description
19
Component
20
Appearance and Components
20
Controller
22
Appearance and Ports
22
Functions and Features
25
Monitoring System
26
Application Conditions
28
Technical Specifications
31
Performance Curves
32
3 Installation
34
Installation Precautions
34
Tools
35
Pipe Connection
36
Material Preparations
37
Automatic Drainpipe
37
Optional) Condensate Pump Drainpipe
38
Optional) Humidifier Water Inlet Pipe
39
Chilled Water Inlet and Outlet Pipes
40
Pipe Support
40
Cables
41
Structural Specifications
42
Netcol5000-C065 External Structure
42
Netcol5000-C080 External Structure
43
Cabinet Holes
43
Unpacking
44
Installation Process
45
Checking the Nitrogen Pressure
45
Removing the Pallet
47
Leveling and Combining Cabinets
48
Securing the Netcol5000-C
50
Connecting Water Pipes
50
Connect Automatic Drainpipe
50
Optional) Connecting the Water Pump Drainpipe
52
Optional) Connecting the Humidifier Water Inlet Pipe
53
Connecting the Chilled Water Inlet and Outlet Pipes
54
Connecting Seamless Steel Pipes
54
Connecting Aluminum Plastic Pipes
55
Optional) Performing a Leakage Test with Nitrogen
57
Injecting Water to Expel Gas
58
Optional) Leakage Test with Water
59
Cable Connections
59
Overview and Precautions
59
Connecting Power Cables
59
Connecting an Equipotential PE Cable
61
Teamwork Networking and Monitoring
62
Main Control Panel
62
Signal Ports
63
Connecting the Teamwork Network Cable
63
Connecting the FE Teamwork Network Cable
63
Connecting the CAN Teamwork Cable
64
Connecting the Monitoring Network Cable
65
Connecting the FE Monitoring Network Cable (Snmp/Modbus-TCP)
65
Connecting the RS485 Monitoring Network Cable (Modbus-RTU)
65
Connecting the Water Sensor
67
Connecting the T/H Sensor Outside the Cabinet
67
Optional) Installing a Differential Pressure Sensor
69
Checking after Installation
70
4 Commissioning
72
Power-On
72
Home Screen
77
Initial Configuration
79
Setting Temperature and Humidity Values and (Optional) Enabling T/H Sensors
79
Optional) Setting the Pressure Difference Control
82
Setting Teamwork Control Parameters
83
Setting Communications Parameters
89
Setting Communications Parameters (Modbus RTU Protocol)
89
Setting Communications Parameters (Modbus TCP Protocol)
89
Setting Communications Parameters (SNMP Protocol)
91
Optional) Setting WIFI Parameters
96
Startup
97
Startup Wizard
101
Optional) Power-Off
105
Checking after Commissioning
106
5 Webui
107
Preparations and Webui Login
107
Webui Introduction
109
6 System Operation and Maintenance
113
Routine Maintenance
113
Routine Maintenance Overview
113
Routine Maintenance Item
114
Alarm References
116
Troubleshooting
161
Parts Replacement
163
Replacement Requirements
163
Replacing the Air Filter
164
Replacing the Humidifier Pump
165
Replacing the Fan
167
Replacing the Wet Film Humidifier
168
Replacing the Differential Pressure Switch
169
Replacing the T/H Sensor
170
Replacing the Return Air Temperature Sensor
171
Replacing the Supply Air Temperature Sensor
172
Replacing the Water Inlet or Outlet Temperature Sensor
174
Replacing a Rectifier
175
Replacing the Water Valve Actuator 1
176
Replacing Water Valve Actuator 2
177
Replacing the Chilled Water Valve
180
Replacing the Controller Panel
181
7 Faq
183
Operations on the LCD
183
Querying Temperature and Humidity Curves
183
Querying Logs
184
Querying Component Status
184
Querying System Parameters
185
Querying Version Details
186
How to View Teamwork Control Information
187
How to Silence the Buzzer
188
How Can I Handle Active Alarms
189
Deleting Historical Alarms
190
Deleting Logs
191
Clearing the Runtime
192
Calibrating a Sensor
192
Calibrating the Screen
193
How to Modify a Password
194
How to Set Alarm Parameters
196
How to Commission Single Component
197
Restoring Factory Settings
198
Which Parameters Are Restored to Default Values after Default Settings Are Operated
201
Exporting Data
201
How to Export and Import a Configuration File
203
How to Import a Certificate and a Key
206
Correlation Relationship of Parameters
207
Webui Operations
209
How to Manage Webui Users
209
How to Install a Network Security Certificate
211
How Can I View Active Alarms and Historical Alarms
212
How Can I Export or Import a Configuration File
212
How Can I Export Fault Information
213
How Can I Change the Smart Cooling Product IP Address on the Webui
213
How Can I View Version Information
214
A Glycol Adding Requirements
215
B Acronyms and Abbreviations
216
C Base Dimensions
217
D Electrical Conceptual Diagram
218
Advertisement
Huawei NetCol5000-C080 Quick Manual (14 pages)
In-row Chilled Water Smart Cooling Product
Brand:
Huawei
| Category:
Industrial Equipment
| Size: 1.95 MB
Table of Contents
Installing the Equipment
3
Installing Cables
7
Verifying the Installation
11
System Power-On
11
Routine Maintenance
14
Advertisement
Related Products
Huawei NetCol5000-C065
Huawei NetCol5000-C030H90D0
Huawei NetCol5000-C030H9HE0
Huawei NetCol5000-C032H9HD0
Huawei NetCol5000-C065H9HD0
Huawei NetCol5000-C065H9HE0
Huawei NetCol5000-C065H90D0
Huawei NetCol5000 C030H6B20 10020E1
Huawei NetCol5000 C030H7B20 1E120E0
Huawei NetCol5000-A020
Huawei Categories
Cell Phone
Network Router
Wireless Router
Modem
Inverter
More Huawei Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL